Programming Guide - HR2150-HP HP Value Barcode Scanner
Enter Setup 
**  Exit  Setup 134 
Set Length Range for MSI-Plessey 
The scanner can be configured to only decode MSI-Plessey barcodes with lengths that fall between (inclusive) the minimum 
and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths. 
Set the Minimum Length (Default: 4) 
Set the Maximum Length (Default: 48) 
If  minimum  length  is  set  to  be  greater  than  maximum  length,  the  scanner  only  decodes  MSI-Plessey 
barcodes with either the minimum or maximum length. If minimum length is same as maximum length, only 
MSI-Plessey barcodes with that length are to be decoded. 
Set the scanner to decode MSI-Plessey barcodes containing between 8 and 12 characters: 
1. Scan the Enter Setup barcode. 
2. Scan the Set the Minimum Length barcode. 
3. Scan the numeric barcode “8” from the “Digit Barcodes” section in Appendix. 
4. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix. 
5. Scan the Set the Maximum Length barcode. 
6. Scan the numeric barcodes “1” and “2” from the “Digit Barcodes” section in Appendix. 
7. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix. 
8. Scan the Exit Setup barcode. 