© Copyright 2016, 2018 HP Development Company, L.P. Windows is either a registered trademark or trademark of Microsoft Corporation in the United States and/or other countries. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty.
Introduction 1 About this Manual 1 Overview 1 Manual Conventions 2 Product Support 2 HP Website Support 2 Programming the Reader 3 Configuration Methods 3 Setup 5 Setting the Interface 5 Customizing Configuration Settings 6 Configure Interface Settings 6 Global Interface Features 6 Configuring Other Features 6 Software Version Transmission 7 Resetting the Product Configuration to Defaults 7 Configuration Using Barcodes 9 Configuration Parameters 9 Global Interface Features 11 Host Commands — Obey/Ignore 11
Label ID Symbology Selection − 1D Symbologies 38 Advanced Formatting: User Label Edit 43 Case Conversion 43 Character Conversion 44 Reading Parameters 45 Double Read Timeout 46 LED and Beeper Indicators 48 Power On Alert 48 Good Read: When to Indicate 48 Good Read Beep Type 49 Good Read Beep Frequency 49 Good Read Beep Length 50 Good Read Beep Volume 51 Scanning Features 52 Scan 52 Stand Mode Illumination Off Time 53 Scanning Active Time 53 Stand Illumination Control 54 Flash On Time 54 Flash Off Time 55 Il
GTIN Formatting 69 EAN 13 (Jan 13) 70 EAN 13 Enable/Disable 70 EAN 13 Check Character Transmission 70 EAN-13 Flag 1 Character 71 EAN-13 ISBN Conversion 71 EAN-13 2D Component 72 ISSN 72 ISSN Enable/Disable 72 EAN 8 (Jan 8) 73 EAN 8 Enable/Disable 73 EAN 8 Check Character Transmission 73 Expand EAN 8 to EAN 13 74 EAN 8 2D Component 74 UPC/EAN Global Settings 75 UPC/EAN Price Weight Check 75 UPC/EAN Quiet Zones 76 Add-Ons 77 Optional Add-ons 77 Optional Add-On Timer 78 Optional GS1-128 Add-On Timer 81 Code 39
Code 128 Check Character Transmission 95 Code 128 Function Character Transmission 95 Code 128 Quiet Zones 96 Code 128 Length Control 96 Code 128 Set Length 1 97 Code 128 Set Length 2 98 GS1-128 99 GS1-128 Enable 99 GS1-128 2D Component 99 Code ISBT 128 100 ISBT 128 Concatenation 100 ISBT 128 Force Concatenation 100 ISBT 128 Concatenation Mode 101 ISBT 128 Dynamic Concatenation Timeout 102 ISBT 128 Advanced Concatenation Options 103 Interleaved 2 of 5 (I 2 of 5) 103 I 2 of 5 Enable/Disable 103 I 2 of 5 Check
Codabar Start/Stop Character Match 120 Codabar Quiet Zones 121 Codabar Length Control 121 Codabar Set Length 1 122 Codabar Set Length 2 123 ABC Codabar 124 ABC Codabar Enable/Disable 124 ABC Codabar Concatenation Mode 124 ABC Codabar Dynamic Concatenation Timeout 125 ABC Codabar Force Concatenation 126 Code 11 127 Code 11 Enable/Disable 127 Code 11 Check Character Calculation 127 Code 11 Check Character Transmission 128 Code 11 Length Control 128 Code 11 Set Length 1 129 Code 11 Set Length 2 130 GS1 DataBar
Plessey Check Character Calculation 148 Plessey Check Character Transmission 149 Plessey Length Control 149 Plessey Set Length 1 150 Plessey Set Length 2 151 2D Symbologies 153 2D Global Features 153 2D Maximum Decoding Time 154 2D Structured Append 155 2D Normal/Inverse Symbol Control 155 Symbology Selection 156 Aztec Code 156 Aztec Code Enable / Disable 156 Aztec Code Length Control 156 Aztec Code Set Length 1 157 Aztec Code Set Length 2 158 China Sensible Code 159 China Sensible Code Enable / Disable 159
Micro QR Code 177 Micro QR Code Enable/Disable 177 Micro QR Code Length Control 177 Micro QR Code Set Length 1 178 Micro QR Code Set Length 2 179 UCC Composite 180 UCC Composite Enable / Disable 180 UCC Optional Composite Timer 181 Postal Code Selection 182 Postnet BB Control 183 References 185 USB COM Parameters 186 Intercharacter Delay 186 ACK NAK Options 187 ACK Character 187 NAK Character 188 ACK NAK Timeout Value 189 ACK NAK Retry Count 190 Disable Character 191 Enable Character 192 Symbologies 193 Set
Chapter 1 Introduction About this Manual This Product Reference Guide (PRG) is provided for users seeking advanced technical information, including connection, programming, maintenance and specifications. Other publications associated with this product are downloadable from the HP website. Overview Chapter 1, (this chapter) presents information about manual conventions, and an overview of the reader, its features and operation. Chapter 2, Setup presents information about setting up the reader.
Product Support Manual Conventions The following conventions are used in this document: The symbols listed below are used in this manual to notify the reader of key issues or procedures that must be observed when using the reader: Notes contain information necessary for properly diagnosing, repairing and operating the reader. The CAUTION symbol advises you of actions that could damage equipment or property.
Programming the Reader Programming the Reader Configuration Methods Programming Barcodes The reader is factory-configured with a standard set of default features. After scanning the interface barcode, you can select other options and customize your reader through use of the instructions and programming barcode labels available in the corresponding features section for your interface. Customizable settings for many features are found in "Configuration Parameters" starting on page 9.
Programming the Reader NOTES 4 Programming Reference Guide
Chapter 2 Setup Setting the Interface Scan the programming barcode from this section which selects the appropriate interface type matching the system the reader will be connected to. Next, proceed to the corresponding section in this manual (also listed in Table 1 on page 5) to configure any desired settings and features associated with that interface. Unlike some programming features and options, interface selections require that you scan only one programming barcode label.
Setup KEYBOARD FEATURES $P,HA2B,P(CR) USB Keyboard with alternate key encoding Select USB Alternate Keyboard $P,HA35,P(CR) USB Keyboard with standard key encoding Select USB Keyboard Set KEYBOARD Interface Features starting on page 21 $P,HA2C,P(CR) USB Keyboard for Apple computers Select USB-KBD-APPLE a. Download the correct USB Com driver from www.hp.
Customizing Configuration Settings Symbology-Specific Parameters 1D Symbologies: Includes options concerning the barcode label types (symbologies). These settings allow you to enable/disable symbologies, set label lengths, require check digit, etc. 2D Symbologies: Includes options concerning the barcode label types (symbologies). These settings allow you to enable/disable symbologies, set label lengths, require check digit, etc.
Setup NOTES 8 Programming Reference Guide
Chapter 3 Configuration Using Barcodes This and following sections provide programming barcodes to configure your reader by changing the default settings. For details about additional methods of programming, see "Configuration Methods" on page 3. You must first enable your reader to read barcodes in order to use this section. If you have not done this, go to Setup, starting on page 5 and complete the appropriate procedure.
Enter/Exit Programming Mode 3. If additional input parameters are needed, go to Appendix D, Keypad, and scan the appropriate characters from the keypad. Additional information about many features can be found in the “References” chapter. If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. 4. Complete the programming sequence by scanning the ENTER/EXIT PROGRAMMING barcode to exit Programming Mode.
Enter/Exit Programming Mode GLOBAL INTERFACE FEATURES The following interface features are configurable by all interface types. Host Commands — Obey/Ignore This option specifies whether the reader will obey or ignore host commands. When set to ignore, the reader will ignore all host commands except for those necessary for: • service mode • flash programming mode • keeping the interface active • transmission of labels.
Enter/Exit Programming Mode NOTES 12 Programming Reference Guide
USB-COM INTERFACE INTERCHARACTER DELAY on page 14 BEEP ON ASCII BEL on page 14 BEEP ON NOT ON FILE on page 15 ACK NAK OPTIONS on page 16 ACK CHARACTER on page 17 NAK CHARACTER on page 17 ACK NAK TIMEOUT VALUE on page 17 ACK NAK RETRY COUNT on page 18 ACK NAK ERROR HANDLING on page 19 INDICATE TRANSMISSION FAILURE on page 19 DISABLE CHARACTER on page 20 ENABLE CHARACTER on page 20 The programming barcodes in this chapter allow modifications to USB-Com interface.
Enter/Exit Programming Mode Intercharacter Delay This parameter specifies the intercharacter delay between the end of one character and the beginning of the next. The delay can be set within a range of zero (0) to 990 milliseconds in 10ms increments. A setting of zero specifies no delay. See page 186 for more information.
Enter/Exit Programming Mode Beep On Not on File This option enables/disables the action of the reader to sound a three beep sequence upon receiving a Not-OnFile (NOF) host command.
Enter/Exit Programming Mode ACK NAK Options This enables/disables the ability of the reader to support the RS-232 ACK/NAK protocol. See page 187 for more information.
Enter/Exit Programming Mode ACK Character This setting specifies an ASCII character or hex value to be used as the ACK character. ASCII characters or any hex value from 0 to 0xFF can be selected. See page 187 for more information. $CR2AC Select ACK Character Setting DEFAULT 0x06 ‘ACK’ Character NAK Character This setting specifies an ASCII character or hex value to be used as the NAK character. ASCII characters or any hex value from 0 to 0xFF can be selected. See page 188 for more information.
Enter/Exit Programming Mode See page 189 for more information on setting this feature. To configure this feature, scan the ENTER/EXIT PROGRAMMING MODE barcode above, then the barcode at left followed by the digits from the Alphanumeric characters in Appendix D, Keypad representing your desired character(s). End by scanning the ENTER/EXIT barcode again. $CR2AT Select ACK NAK Timeout Value Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string.
Enter/Exit Programming Mode ACK NAK Error Handling This feature specifies the method the reader uses to handle receive errors detected while waiting for an ACK character from the host.
Enter/Exit Programming Mode Disable Character Specifies the value of the RS-232 host command used to disable the reader. ASCII characters or any hex value from 0 to 0xFF can be selected. See page 191 for more information on setting this feature. $CR2DC Select Disable Character Setting DEFAULT 0x44 = Disable Character is ‘D’ Enable Character Specifies the value of the RS-232 host command used to enable the reader. ASCII characters or any hex value from 0 to 0xFF can be selected.
KEYBOARD SETTINGS COUNTRY MODE on page 22 SEND CONTROL CHARACTERS on page 26 CAPS LOCK STATE on page 27 NUMLOCK on page 27 USB KEYBOARD SPEED on page 28 USB KEYBOARD NUMERIC KEYPAD on page 29 Use the programming barcodes in this chapter to select options for USB Keyboard Interface. Reference Appendix B, Standard Defaults for a listing of standard factory settings. Information about control character emulation which applies to keyboard interfaces is listed in Appendix E, Scancode Tables.
Enter/Exit Programming Mode Country Mode This feature specifies the country/language supported by the keyboard. Several languages are supported: $CKBCO00(CR) DEFAULT Country Mode = U.S. $CKBCO01(CR) Country Mode = Belgium $CKBCO02(CR) Country Mode = Britain $CKBCO11(CR) Supports only the interfaces listed in the Country Mode feature description. Country Mode = Croatia $CKBCO0E(CR) Supports only the interfaces listed in the Country Mode feature description.
Enter/Exit Programming Mode Country Mode (continued) $CKBCO04(CR) Country Mode = France $CKBCO13(CR) Supports only the interfaces listed in the Country Mode feature description. Country Mode = French Canadian $CKBCO05(CR) Country Mode = Germany $CKBCO0D(CR) Supports only the interfaces listed in the Country Mode feature description. Country Mode = Hungary $CKBCO06(CR) Country Mode = Italy $CKBCO0C(CR) Supports only the interfaces listed in the Country Mode feature description.
Enter/Exit Programming Mode Country Mode (continued) $CKBCO14(CR) Supports only the interfaces listed in the Country Mode feature description. Country Mode = Lithuanian $CKBCO07(CR) Country Mode = Norway $CKBCO12(CR) Supports only the interfaces listed in the Country Mode feature description. Country Mode = Poland Supports only the interfaces listed in the Country Mode feature description.
Enter/Exit Programming Mode Country Mode (continued) $CKBCO09(CR) Country Mode = Spain $KBCO0A(CR) Country Mode = Sweden $CKBCO0B(CR) Supports only the interfaces listed in the Country Mode feature description.
Enter/Exit Programming Mode Send Control Characters This feature specifies how the reader transmits ASCII control characters to the host. Reference Appendix E, Scancode Tables for more information about control characters. Options are as follows: Control Character 00 : Characters from 00 to 0x1F are sent as control character Ctrl+Keys, special keys are located from 0x80 to 0xA1.
Enter/Exit Programming Mode Caps Lock State This option specifies the format in which the reader sends character data. This does not apply when an alternate key encoding keyboard is selected. $CKBCL00(CR) DEFAULT Caps Lock State = Caps Lock OFF $CKBCL01(CR) Caps Lock State = Caps Lock ON $CKBCL02(CR) Caps Lock State = AUTO Caps Lock Enable Numlock This option specifies the setting of the NUMLOCK key in the Keyboard Wedge interface.
Enter/Exit Programming Mode USB Keyboard Speed This option specifies the USB poll rate for a USB keyboard. This feature applies ONLY to the USB Keyboard interface.
Enter/Exit Programming Mode USB Keyboard Speed (continued) $CKBSP07(CR) USB Keyboard Speed = 7ms $CKBSP08(CR) USB Keyboard Speed = 8ms $CKBSP09(CR) USB Keyboard Speed = 9ms $CKBSP0A(CR) USB Keyboard Speed = 10ms USB Keyboard Numeric Keypad This option Controls whether numeric characters will be sent using standard keys or the numeric keypad.
Enter/Exit Programming Mode NOTES 30 Programming Reference Guide
DATA FORMAT GLOBAL PREFIX/SUFFIX starting on page 32 GLOBAL AIM ID starting on page 33 LABEL ID starting on page 36 • • • • • Label ID: Pre-Loaded Sets Individually Set Label ID Label ID Control Label ID Symbology Selection − 1D Symbologies Label ID Symbology Selection − 2D Symbologies CASE CONVERSION starting on page 43 CHARACTER CONVERSION starting on page 44 It is not recommended to use these features with IBM interfaces.
Enter/Exit Programming Mode Global Prefix/Suffix Global Prefix/Suffix This option sets up to 20 characters each from the set of ASCII characters or any hex value from 00 to FF. The characters may be added as a prefix (in a position before the barcode data, also called a header) and/or as a suffix (in a position following the barcode data, also called a footer). See page 195 for more detailed instructions on setting this feature.
Global AIM ID Enter/Exit Programming Mode Global AIM ID This feature enables/disables addition of AIM IDs for all symbology types. AIM label identifiers (as opposed to custom characters you select yourself as with label identifiers) can be included with scanned barcode data. See Table 2 on page 3-33 for a listing of AIM IDs. AIM label identifiers consist of three characters as follows: • A close brace character (ASCII ‘]’), followed by...
Enter/Exit Programming Mode DATABAR EXPANDED COMPOSITE DATABAR LIMITED DATABAR LIMITED COMPOSITE DATA MATRIX EAN128 EAN128 COMPOSITE EAN13 EAN13 P2 EAN13 P5 EAN13 COMPOSITE EAN8 EAN8 P2 EAN8 P5 EAN8 COMPOSITE FOLLET 2OF5 I2OF5 IATA INDUSTRIAL 2OF5 INDUSTRIAL 2OF5 ISBN ISBT128 CONCAT ISSN MAXICODE MICRO QR MICRO PDF MSI PDF417 PLESSEY POSTAL AUSTRALIAN POSTAL IMB POSTAL JAPANESE POSTAL KIX POSTAL PLANET POSTAL PORTUGAL POSTAL POSTNET BB POSTAL ROYAL MAIL POSTAL SWEDISH POSTNET QR CODE S25 TRIOPTIC UPCA UPCA
Global AIM ID Enter/Exit Programming Mode Set AIM ID Individually for GS1-128 This feature configures a Label ID individually for the GS1-128 symbology and the programming for this works the same way as Label ID. See Label ID: Set Individually Per Symbology, starting on page 200 for detailed instructions on setting this feature.
Enter/Exit Programming Mode Label ID Label ID A Label ID is a customizable code of up to three ASCII characters (convert to Hex using the ASCII Chart on the inside back cover of this manual), used to identify a barcode symbology type. It can be appended previous to or following the transmitted barcode data depending upon how this option is enabled. This feature provides options for configuring custom Label IDs or individually per symbology (see "Individually Set Label ID" on page 37).
Label ID Enter/Exit Programming Mode Individually Set Label ID This feature configures a Label ID individually for a single symbology. To set, first define whether you want it as a prefix or suffix by scanning a label below. Then turn to Label ID Symbology Selection − 1D Symbologies, starting on page 38 to select the symbology you want to set, followed by up to 3 characters from the ASCII Chart at the back of this manual.
Enter/Exit Programming Mode Label ID Label ID Symbology Selection − 1D Symbologies This option selects the symbology for which a Label ID is to be configured. See "Label ID" on page 36 or page 197 in “References” for more detailed instructions. If less than the expected string of 3 characters are selected, scan the ENTER/EXIT barcode twice to accept the selection and exit Programming Mode.
Label ID Enter/Exit Programming Mode Label ID Symbology Selection − 1D Symbologies (continued) $CCCID Set Code 39 CIP Label ID Character(s) $C8BID Set EAN 8 Label ID Character(s) $C8MID Set EAN 8 Composite Label ID Character(s) $C82ID Set EAN 8 P2 Label ID Character(s) $C85ID Set EAN 8 P5 Label ID Character(s) $CF2ID Set Follett 2 of 5 Label ID Character(s) $C4BID Set GS1 DataBar 14 Label ID Character(s) $C4CID Set GS1 DataBar 14 Composite Label ID Character(s) Programming Reference Guide $C35
Enter/Exit Programming Mode Label ID Label ID Symbology Selection − 1D Symbologies (continued) $CXBID Set GS1 DataBar Expanded Label ID Character(s) $CIAID Set IATA Industrial 2 of 5 Label ID Character(s) $CPMID Set IMB Postal Code Label ID Character(s) $CU2ID Set Industrial 2 of 5 Label ID Character(s) $CI2ID Set Interleaved 2 of 5 Label ID Character(s) $CISID Set ISBN Label ID Character(s) $CINID Set ISSN Label ID Character(s) $CPJID Set Japan Postal Code Label ID Character(s) 40 $CGBID Set
Label ID Enter/Exit Programming Mode Label ID Symbology Selection − 1D Symbologies (continued) $CPZID Set PZN Code Label ID Character(s) $CPRID Set Royal Postal Code Label ID Character(s) $CS2ID Set Standard 2 of 5 Label ID Character(s) $CPSID Set Swedish Postal Code Label ID Character(s) $CCTID Set Trioptic Code Label ID Character(s) $CAMID Set UPC-A Composite Label ID Character(s) $CA2ID Set UPC-A P2 Label ID Character(s) $CA5ID Set UPC-A P5 Label ID Character(s) $CEBID Set UPC-E Label ID Char
Enter/Exit Programming Mode Label ID Label ID Symbology Selection − 2D Symbologies $CAZID Set Aztec Label ID Character(s) $CCSID Set China Sensible Label ID Character(s) $CDMID Set Data Matrix Label ID Character(s) $CMQID Set Micro QR Label ID Character(s) 42 $CMXID Set Maxicode Label ID Character(s) $CP4ID Set PDF 417 Label ID Character(s) $CMIID Set Micro PDF 417 Label ID Character(s) $CQRID Set QR Code Label ID Character(s) Programming Reference Guide
Label ID Enter/Exit Programming Mode Advanced Formatting: User Label Edit Advanced formatting is available to create user label edit scripts. See the HP configuration application or contact Technical Support. Case Conversion This feature allows conversion of the case of all alphabetic characters to upper or lower case. Case conversion affects ONLY scanned barcode data, and does not affect Label ID, Prefix, Suffix, or other appended data.
Enter/Exit Programming Mode Label ID Character Conversion Character conversion is an eight byte configuration item. The eight bytes are 4 character pairs represented in hexadecimal ASCII values. The first character in the pair is the character that will be converted. The second character in the pair is the character to convert to. If the character to convert in a pair is FF, then no conversion is done.
READING PARAMETERS DOUBLE READ TIMEOUT starting on page 46 LED AND BEEPER INDICATORS starting on page 48 • • • • • • Power On Alert Good Read: When to Indicate Good Read Beep Type Good Read Beep Frequency Good Read Beep Length Good Read Beep Volume SCANNING FEATURES starting on page 52 • • • • • • • • • • • • • • Scan Stand Mode Illumination Off Time Stand Mode Illumination Off Time Scanning Active Time Stand Illumination Control Flash On Time Flash Off Time Illumination: Brightness Aiming Pointer Aiming
Enter/Exit Programming Mode Double Read Timeout Double Read Timeout prevents a double read of the same label by setting the minimum time allowed between reads of labels of the same symbology and data. If the unit reads a label and sees the same label again within the specified timeout, the second read is ignored. Double Read Timeout does not apply to scan modes that require the software trigger to be selected for each label read. $CSNDR0A(CR) Double Read Timeout = 0.
Enter/Exit Programming Mode Double Read Timeout (continued) $CSNDR50(CR) Double Read Timeout = 0.8 Second $CSNDR5A(CR) Double Read Timeout = 0.
Enter/Exit Programming Mode LED AND BEEPER INDICATORS Power On Alert Disables or enables the indication (from the Beeper) that the reader is receiving power. $CBPPU00(CR) DEFAULT Power On Alert = Disable (No Audible Indication) $CBPPU01(CR) Power On Alert = Power-up Beep Good Read: When to Indicate This feature specifies when the reader will provide indication (beep and/or flash its green LED) upon successfully reading a barcode.
Enter/Exit Programming Mode Good Read Beep Type Specifies whether the good read beep has a mono or bitonal beep sound. $CBPTY00(CR) DEFAULT Good Read Beep Type = Mono $CBPTY01(CR) Good Read Beep Type = Bitonal Good Read Beep Frequency Adjusts the good read beep to sound at a selectable low, medium or high frequency, selectable from the list below. (Controls the beeper’s pitch/tone.
Enter/Exit Programming Mode Good Read Beep Length $CBPLE06(CR) Good Read Beep Length = 60 msec $CBPLE08(CR) DEFAULT Good Read Beep Length = 80 msec $CBPLE0A(CR) Good Read Beep Length = 100 msec $CBPLE0C(CR) Good Read Beep Length = 120 msec $CBPLE0E(CR) Good Read Beep Length = 140 msec $CBPLE10(CR) Good Read Beep Length = 160 msec $CBPLE12(CR) Good Read Beep Length = 180 msec $CBPLE14(CR) Good Read Beep Length = 200 msec 50 Programming Reference Guide
Enter/Exit Programming Mode Good Read Beep Volume Selects the beeper volume (loudness) upon a good read beep. There are three selectable volume levels.
Enter/Exit Programming Mode SCANNING FEATURES Scan Selects the reader’s scan operating mode. See page 203 in “References” for descriptions.
Enter/Exit Programming Mode Stand Mode Illumination Off Time Specifies the amount of time reader illumination stays off after selecting the software trigger when in Stand Mode. The configurable range is 01 to 32 by 01 in increments of 500ms (500ms to 16 seconds). See page 204 in “References” for a description of this feature.
Enter/Exit Programming Mode Stand Illumination Control Controls the illumination status while the reading mode is stand mode and the reader is attempting to detect objects. $CSMIL00(CR) DEFAULT Stand Illumination Control = OFF $CSMIL01(CR) Stand Illumination Control = ON $CSMIL02(CR) Stand Illumination Control = Dim Flash On Time This feature specifies the ON time for the indicator LED while in Flash Mode. The selectable range is 100 to 9,900 milliseconds (0.1 to 9.
Enter/Exit Programming Mode Flash Off Time This feature specifies the OFF time for the indicator LED while in Flash Mode. The selectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond increments. See page 208 in “References” for detailed information on setting this feature.
Enter/Exit Programming Mode Reducing the LED brightness can reduce scanning performance. Aiming Pointer Enables/disables the aiming pointer for all symbologies. $CTAAP00(CR) Aiming Pointer = Disable $CTAAP01(CR) DEFAULT Aiming Pointer = Enable Aiming Duration Timer Specifies the frame of time the aiming pointer remains on after decoding a label, when in trigger single mode.The range for this setting is from 1 to 255 seconds in 1-second increments.
Enter/Exit Programming Mode Green Spot Duration Specifies the duration of the good read pointer beam after a good read. $CLSSP00(CR) Green Spot Duration = Disable (Green Spot is Off ) $CLSSP01(CR) DEFAULT Green Spot Duration = Short (300 msec) $CLSSP02(CR) Green Spot Duration = Medium (500 msec) $CLSSP03(CR) Green Spot Duration = Long (800 msec) Mobile Phone Mode This mode is useful for scanning barcodes displayed on a mobile phone.
Enter/Exit Programming Mode Partial Label Reading Control Enable/Disable to ignore partial labels to be read within the boundary of the field of view. IPPL00 Partial Label Reading Control = Disable IPPL01 Partial Label Reading Control = Enable Decode Negative Image Enable/Disable the ability to decode a negative image for all symbologies. When this feature is enabled, you will be unable to read normally-printed labels or programming labels in this manual.
Enter/Exit Programming Mode MULTIPLE LABEL READING In standard (default) mode, when the reader’s aiming system is activated (by selecting the software trigger, motion or other method depending on the mode), it then acquires and processes each image in the area in front of it (the Volume). In this case, the scanner stops processing the image once it decodes a label. If several labels are present in the volume, only the first label encountered is decoded and sent.
Enter/Exit Programming Mode Multiple Labels Ordering by Code Symbology This feature allows you to specify the order multiple labels are transmitted by symbology type, when Multiple Labels per Frame is enabled. See page 209 in “References” for detailed information on setting this feature.
1D SYMBOLOGIES 1D Code Selection The reader supports the following 1D symbologies (barcode types). See "2D Symbologies" starting on page 153 for 2D barcodes. Symbology-dependent options are included in each chapter.
Enter/Exit Programming Mode 1D Code Selection DISABLE ALL SYMBOLOGIES Use this feature to disable all symbologies. 1. Scan the ENTER/EXIT PROGRAMMING Mode barcode. 2. Scan the Disable All Symbologies barcode. 3. Complete the programming sequence by scanning the ENTER/EXIT PROGRAMMING barcode. $AD(CR) Disable All Symbologies This does not disable the reading of programming labels.
1D Code Selection Enter/Exit Programming Mode CODE EAN/UPC Coupon Control This feature is used to control the reader’s method of processing coupon labels.
Enter/Exit Programming Mode 1D Code Selection UPC-A The following options apply to the UPC-A symbology. UPC-A Enable/Disable When disabled, the reader will not read UPC-A barcodes. $CABEN00(CR) UPC-A = Disable $CABEN01(CR) DEFAULT UPC-A = Enable UPC-A Check Character Transmission Enable this option to transmit the check character along with UPC-A barcode data.
1D Code Selection Enter/Exit Programming Mode Expand UPC-A to EAN-13 Expands UPC-A data to the EAN-13 data format. Selecting this feature also changes the symbology ID to match those required for EAN-13. $CAB3B00(CR) DEFAULT UPC-A to EAN-13 = Don’t Expand $CAB3B01(CR) UPC-A to EAN-13 = Expand UPC-A Number System Character Transmission This feature enables/disables transmission of the UPC-A number system character.
Enter/Exit Programming Mode 1D Code Selection UPC-A 2D Component This feature enables/disables a requirement that a 2D label component be decoded when a base label of this symbology is decoded. $CAB2D00(CR) DEFAULT EAN-13 2D Component = Disable (2D component not required) $CAB2D01(CR) EAN-13 2D Component = 2D component must be decoded UPC-E The following options apply to the UPC-E symbology. UPC-E Enable/Disable When disabled, the reader will not read UPC-E barcodes.
1D Code Selection Enter/Exit Programming Mode UPC-E Check Character Transmission Enable this option to transmit the check character along with UPC-E barcode data. $CEBCT00(CR) UPC-E Check Character Transmission = Don’t Send $CEBCT01(CR) DEFAULT UPC-E Check Character Transmission = Send UPC-E 2D Component This feature enables/disables a requirement that a 2D label component be decoded when a base label for this symbology is decoded.
Enter/Exit Programming Mode 1D Code Selection Expand UPC-E to EAN-13 Expands UPC-E data to the EAN-13 data format. Selecting this feature also changes the symbology ID to match those required for EAN-13. $CEB3B00(CR) DEFAULT UPC-E to EAN-13 = Don’t Expand $CEB3B01(CR) UPC-E to EAN-13 = Expand Expand UPC-E to UPC-A Expands UPC-E data to the UPC-A data format.
1D Code Selection Enter/Exit Programming Mode UPC-E Number System Character Transmission This feature enables/disables transmission of the UPC-E system number character. $CEBNS00(CR) UPC-E Number System Character = Do not transmit $CEBNS01(CR) DEFAULT UPC-E Number System Character = Transmit GTIN FORMATTING This feature enables/disables the ability to convert UPC-E, UPC-A, EAN 8, and EAN 13 labels into the GTIN 14-character format.
Enter/Exit Programming Mode 1D Code Selection EAN 13 (JAN 13) The following options apply to the EAN 13 (Jan 13) symbology. EAN 13 Enable/Disable When disabled, the reader will not read EAN 13/JAN 13 barcodes. $C3BEN00(CR) EAN 13 = Disable $C3BEN01(CR) DEFAULT EAN 13 = Enable EAN 13 Check Character Transmission Enable this option to transmit the check character along with EAN 13 barcode data.
1D Code Selection Enter/Exit Programming Mode EAN-13 Flag 1 Character Enables/disables transmission of an EAN/JAN13 Flag1 character. The Flag 1 character is the first character of the label. $C3BF100(CR) EAN-13 Flag 1 Char= Don’t transmit $C3BF101(CR) DEFAULT EAN-13 Flag 1 Char= Transmit EAN-13 ISBN Conversion This option enables/disables conversion of EAN 13/JAN 13 Bookland labels starting with 978 to ISBN labels.
Enter/Exit Programming Mode 1D Code Selection EAN-13 2D Component This feature enables/disables a requirement that a 2D label component be decoded when a base label of this symbology is decoded. $C3B2D00(CR) DEFAULT EAN-13 2D Component = Disable (2D component not required) $C3B2D01(CR) EAN-13 2D Component = 2D component must be decoded ISSN The following options apply to the ISSN symbology. ISSN Enable/Disable Enables/disables conversion of EAN/JAN13 Bookland labels starting with 977 to ISSN labels.
1D Code Selection Enter/Exit Programming Mode EAN 8 (JAN 8) The following options apply to the EAN 8 (Jan 8) symbology. EAN 8 Enable/Disable When disabled, the reader will not read EAN 8/JAN 8 barcodes. $C8BEN00(CR) EAN 8 = Disable $C8BEN01(CR) DEFAULT EAN 8 = Enable EAN 8 Check Character Transmission Enable this option to transmit the check character along with EAN 8 barcode data.
Enter/Exit Programming Mode 1D Code Selection Expand EAN 8 to EAN 13 Enable this option to expand EAN 8/JAN 8 labels to EAN 13/JAN 13. $C8B3B00(CR) DEFAULT Expand EAN 8 to EAN 13 = Disable $C8B3B01(CR) Expand EAN 8 to EAN 13 = Enable EAN 8 2D Component This feature enables/disables a requirement that a 2D label component be decoded when a base label for this symbology is decoded.
1D Code Selection Enter/Exit Programming Mode UPC/EAN GLOBAL SETTINGS This section provides configuration settings for UPC-A, UPC-E, EAN 13 and EAN 8 symbologies, and affects all of these unless otherwise marked for each feature description. UPC/EAN Price Weight Check This feature enables/disables calculation and verification of price/weight check digits.
Enter/Exit Programming Mode 1D Code Selection UPC/EAN Quiet Zones This feature specifies the number of quiet zones for UPC/EAN labels. Quiet zones are blank areas at the ends of a barcode, typically 10 times the width of the narrowest bar or space in the label. The property applies to all EAN-UPC symbologies globally and to the ADDONs.
1D Code Selection Enter/Exit Programming Mode ADD-ONS Contact Customer Support for advanced programming of optional and conditional add-ons. Optional Add-ons The reader can be enabled to optionally read the following add-ons (supplementals): If a UPC/EAN base label and an add-on are both decoded, the reader will transmit the base label and add-on. If a UPC/EAN base label is decoded without an add-on, the base label will be transmitted without an add-on.
Enter/Exit Programming Mode 1D Code Selection Optional Add-On Timer This option sets the time the reader will look for an add-on when an add-on fragment has been seen and optional add-ons are enabled. (Also see "Optional GS1-128 Add-On Timer" on page 81.
1D Code Selection Enter/Exit Programming Mode Optional Add-On Timer (continued) $CADOT06(CR) Optional Add-on Timer = 60ms $CADOT07(CR) DEFAULT Optional Add-on Timer = 70ms $CADOT0A(CR) Optional Add-on Timer = 100ms $CADOT0C(CR) Optional Add-on Timer = 120ms $CADOT0E(CR) Optional Add-on Timer = 140ms $CADOT10(CR) Optional Add-on Timer = 160ms Programming Reference Guide 79
Enter/Exit Programming Mode 1D Code Selection Optional Add-On Timer (continued) $CADOT12(CR) Optional Add-on Timer = 180ms $CADOT14(CR) Optional Add-on Timer = 200ms $CADOT16(CR) Optional Add-on Timer = 220ms $CADOT18(CR) Optional Add-on Timer = 240ms $CADOT1A(CR) Optional Add-on Timer = 260ms $CADOT1C(CR) Optional Add-on Timer = 280ms $CADOT1E(CR) Optional Add-on Timer = 300ms 80 Programming Reference Guide
1D Code Selection Enter/Exit Programming Mode Optional GS1-128 Add-On Timer This option sets the timer expiration value to read the added part after reading the linear EAN/UPC part. For UPC/EAN add-ons other than those of that type, see "Optional Add-On Timer" on page 78.
Enter/Exit Programming Mode 1D Code Selection Optional GS1-128 Add-On Timer (continued) $CADUT06(CR) Optional GS1-128 Add-On Timer = 60ms $CADUT07(CR) Optional GS1-128 Add-On Timer = 70ms $CADUT0A(CR) Optional GS1-128 Add-On Timer = 100ms $CADUT0C(CR) Optional GS1-128 Add-On Timer = 120ms $CADUT0E(CR) Optional GS1-128 Add-On Timer = 140ms $CADUT10(CR) Optional GS1-128 Add-On Timer = 160ms 82 Programming Reference Guide
1D Code Selection Enter/Exit Programming Mode Optional GS1-128 Add-On Timer (continued) $CADUT12(CR) Optional GS1-128 Add-On Timer = 180ms $CADUT14(CR) Optional GS1-128 Add-On Timer = 200ms $CADUT16(CR) Optional GS1-128 Add-On Timer = 220ms $CADUT18(CR) Optional GS1-128 Add-On Timer = 240ms $CADUT1A(CR) Optional GS1-128 Add-On Timer = 260ms $CADUT1C(CR) Optional GS1-128 Add-On Timer = 280ms $CADUT1E(CR) Optional GS1-128 Add-On Timer = 300ms Programming Reference Guide 83
Enter/Exit Programming Mode 1D Code Selection CODE 39 The following options apply to the Code 39 symbology. Code 39 Enable/Disable $CC3EN00(CR) Code 39 = Disable $CC3EN01(CR) DEFAULT Code 39 = Enable Code 39 Check Character Calculation Enable this option to enables/disables calculation and verification of an optional Code 39 check character.
1D Code Selection Enter/Exit Programming Mode Code 39 Check Character Calculation (continued) $CC3CC04(CR) Code 39 Check Character Calculation = Enable Italian Post Check $CC3CC08(CR) Code 39 Check Character Calculation = Enable Daimler Chrysler Check Code 39 Check Character Transmission Enable this option to transmit the check character along with Code 39 barcode data.
Enter/Exit Programming Mode 1D Code Selection Code 39 Start/Stop Character Transmission Enable this option to enable/disable transmission of Code 39 start and stop characters. $CC3SS00(CR) DEFAULT Code 39 Start/Stop Character Transmission = Don’t Transmit $CC3SS01(CR) Code 39 Start/Stop Character Transmission = Transmit Code 39 Full ASCII Enables/disables the translation of Code 39 characters to Code 39 full-ASCII characters.
1D Code Selection Enter/Exit Programming Mode Code 39 Quiet Zones This feature specifies the number of quiet zones for Code 39 labels. Quiet zones are blank areas at the ends of a barcode, typically 10 times the width of the narrowest bar or space in the label.
Enter/Exit Programming Mode 1D Code Selection Code 39 Set Length 1 This feature specifies one of the barcode lengths for Code 39 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the barcode’s data characters only. The length can be set from 0 to 50 characters. Table 3 provides examples for setting Length 1. See page 193 for detailed instructions on setting this feature. Table 3.
1D Code Selection Enter/Exit Programming Mode Code 39 Set Length 2 This feature specifies one of the barcode lengths for Code 39 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the barcode’s check, data, and full-ASCII shift characters. The length does not include start/stop characters. Table 4 provides examples for setting Length 2. See page 193 for detailed instructions on setting this feature. Table 4.
Enter/Exit Programming Mode 1D Code Selection TRIOPTIC CODE The following options apply to the Trioptic symbology. Trioptic Code Enable/Disable $CCTEN00(CR) DEFAULT Trioptic Code = Disable $CCTEN01(CR) Trioptic Code = Enable CODE 32 (ITAL PHARMACEUTICAL CODE) The following options apply to the Code 32 (Italian Pharmaceutical Code) symbology. Code 32 Enable/Disable When disabled, the reader will not read Code 32 barcodes.
1D Code Selection Enter/Exit Programming Mode Code 32 Feature Setting Exceptions The following features are set for Code 32 by using these Code 39 settings: "Code 39 Quiet Zones" on page 87 "Code 39 Length Control" on page 87 "Trioptic Code" on page 90 Code 32 Check Char Transmission Enable this option to transmit the check character along with Code 32 barcode data.
Enter/Exit Programming Mode 1D Code Selection CODE 39 CIP (FRENCH PHARMACEUTICAL) The following options apply to the Code 39 CIP symbology. Code 39 CIP Enable/Disable Enables/Disables ability of the reader to decode Code 39 CIP labels. $CCCEN00(CR) DEFAULT Code 39 CIP = Disable $CCCEN01(CR) Code 39 CIP = Enable CODE 39 DANISH PPT The following options apply to the Code 39 Danish PPT symbology. Code 39 Danish PPT Enable/Disable Enables/Disables AIM ID for Code 39 Danish PPT Codes.
1D Code Selection Enter/Exit Programming Mode CODE 39 LAPOSTE The following options apply to the Code 39 LaPoste symbology. Code 39 LaPoste Enable/Disable Enables/disables the ability of the scanner to decode Code39 La Poste labels. $CLPEN00(CR) DEFAULT Code 39 LaPoste = Disable $CLPEN01(CR) Code 39 LaPoste = Enable CODE 39 PZN The following options apply to the Code 39 PZN symbology. Code 39 PZN Enable/Disable Enables/disables the ability of the scanner to decode Code39 PZN labels.
Enter/Exit Programming Mode 1D Code Selection CODE 128 The following options apply to the Code 128 symbology. Code 128 Enable/Disable When disabled, the reader will not read Code 128 barcodes. $CC8EN00(CR) Code 128 = Disable $CC8EN01(CR) DEFAULT Code 128 = Enable Expand Code 128 to Code 39 This feature enables/disables expansion of Code 128 labels to Code 39 labels.
1D Code Selection Enter/Exit Programming Mode Code 128 Check Character Transmission Enable this option to transmit the check character along with Code 128 barcode data. $CC8CT00(CR) DEFAULT Code 128 Check Character Transmission = Don’t Send $CC8CT01(CR) Code 128 Check Character Transmission = Send Code 128 Function Character Transmission Enables/disables transmission of Code128 function characters 1, 2, 3, and 4.
Enter/Exit Programming Mode 1D Code Selection Code 128 Quiet Zones This feature specifies the number of quiet zones for Code 128 labels. Quiet zones are blank areas at the ends of a barcode and are typically 10 times the width of the narrowest bar or space in the label.
1D Code Selection Enter/Exit Programming Mode Code 128 Set Length 1 Specifies one of the barcode lengths for Code 128 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the barcode’s data characters only. The length can be set from 1 to 80 characters. Table 5 provides some examples for setting Length 1. See page 193 for detailed instructions on setting this feature. Table 5.
Enter/Exit Programming Mode 1D Code Selection Code 128 Set Length 2 This feature specifies one of the barcode lengths for Code 128 Length Control. Length 2 is the maximum label length if in Set Length 2 Mode, or the second fixed length if in Set Length 1 Mode. Length includes the barcode’s data characters only. The length can be set from 1 to 80 characters. A setting of 0 specifies to ignore this length (only one fixed length). Table 6 provides examples for setting Length 2.
1D Code Selection Enter/Exit Programming Mode GS1-128 The following options apply to the GS1-128 symbology. (Also known as USS-128, GS1-128, GTIN-128, UCC-128, EAN-128.) GS1-128 Enable This option enables/disables the ability of the reader to translate GS1-128 labels to the GS1-128 data format. Options are: • Transmit GS1-128 labels in Code 128 data format. • Transmit GS1-128 labels in GS1-128 data format. • Do not transmit GS1-128 labels.
Enter/Exit Programming Mode 1D Code Selection CODE ISBT 128 The following options apply to the ISBT 128 symbology. ISBT 128 Concatenation Use this option to enable/disable ISBT128 concatenation of 2 labels. $CI8CE00(CR) DEFAULT ISBN 128 Concatenation = Disable $CI8CE01(CR) ISBN 128 Concatenation = Enable ISBT 128 Force Concatenation When enabled, this feature forces concatenation for ISBT. This option is only valid when ISBT 128 Concatenation is enabled.
1D Code Selection Enter/Exit Programming Mode ISBT 128 Concatenation Mode Specifies the concatenation mode between Static and Dynamic. This option is only valid when ISBT 128 Concatenation is enabled (see "ISBT 128 Concate- nation" on page 100).
Enter/Exit Programming Mode 1D Code Selection ISBT 128 Dynamic Concatenation Timeout Specifies the timeout used by the ISBT 128 Dynamic Concatenation Mode.
1D Code Selection Enter/Exit Programming Mode ISBT 128 Advanced Concatenation Options To set up pairs of label types for concatenation, use the HP Configuration application or contact HP Technical Support, as described on page 2. INTERLEAVED 2 OF 5 (I 2 OF 5) The following options apply to the I 2 of 5 symbology. I 2 of 5 Enable/Disable When disabled, the reader will not read I 2 of 5 barcodes.
Enter/Exit Programming Mode 1D Code Selection I 2 of 5 Check Character Calculation This option enables/disables calculation and verification of an optional I 2 of 5 check character. Combinations of these settings are possible via the HP configuration utility, or contact Technical Support.
1D Code Selection Enter/Exit Programming Mode I 2 of 5 Check Character Transmission Enable this option to transmit the check character along with I 2 of 5 barcode data. $CI2CT00(CR) I 2 of 5 Check Character Transmission = Don’t Send $CI2CT01(CR) DEFAULT I 2 of 5 Check Character Transmission = Send I 2 of 5 Length Control This feature specifies either variable length decoding or fixed length decoding for the I 2 of 5 symbology.
Enter/Exit Programming Mode 1D Code Selection I 2 of 5 Set Length 1 This feature specifies one of the barcode lengths for I 2 of 5 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. The length includes the barcode’s check and data characters. The length can be set from 2 to 50 characters in increments of two. Table 7 provides some examples for setting Length 1. See page 193 for detailed instructions on setting this feature.
1D Code Selection Enter/Exit Programming Mode I 2 of 5 Set Length 2 This feature specifies one of the barcode lengths for I 2 of 5 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. The length includes the barcode’s check and data characters. The length can be set from 2 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length). Table 8 provides examples for setting Length 2.
Enter/Exit Programming Mode 1D Code Selection INTERLEAVED 2 OF 5 CIP HR The following options apply to the Interleaved 2 of 5 CIP HR symbology. Interleaved 2 of 5 CIP HR Enable/Disable Enables/Disables ability of reader to decode Interleaved 2 of 5 CIP HR labels. $CCHEN00(CR) DEFAULT Interleaved 2 of 5 CIP HR = Disable $CCHEN01(CR) Interleaved 2 of 5 CIP HR = Enable FOLLETT 2 OF 5 The following options apply to the Follett 2 of 5 symbology.
1D Code Selection Enter/Exit Programming Mode STANDARD 2 OF 5 The following options apply to the Standard 2 of 5 symbology. Standard 2 of 5 Enable/Disable When disabled, the reader will not read Standard 2 of 5 barcodes. $CS2EN00(CR) DEFAULT Standard 2 of 5 = Disable $CS2EN01(CR) Standard 2 of 5 = Enable Standard 2 of 5 Check Character Calculation This option enables/disables calculation and verification of an optional Standard 2 of 5 check character.
Enter/Exit Programming Mode 1D Code Selection Standard 2 of 5 Check Character Transmission This feature enables/disables transmission of an optional Standard 2 of 5 check character. $CS2CT00(CR) Standard 2 of 5 Check Character Transmission = Don’t Send $CS2CT01(CR) DEFAULT Standard 2 of 5 Check Character Transmission = Send Standard 2 of 5 Length Control This feature specifies either variable length decoding or fixed length decoding for the Standard 2 of 5 symbology.
1D Code Selection Enter/Exit Programming Mode Standard 2 of 5 Set Length 1 This feature specifies one of the barcode lengths for Standard 2 of 5 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the barcode’s check and data characters. The length can be set from 1 to 50 characters. Table 9 provides some examples for setting Length 1. See page 193 if you want detailed instructions on setting this feature.
Enter/Exit Programming Mode 1D Code Selection Standard 2 of 5 Set Length 2 This feature specifies one of the barcode lengths for Standard 2 of 5 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the barcode’s check and data characters. The length can be set from 1 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length). Table 10 provides examples for setting Length 2.
1D Code Selection Enter/Exit Programming Mode INDUSTRIAL 2 OF 5 The following options apply to the Industrial 2 of 5 symbology. Industrial 2 of 5 Enable/Disable Enables/Disables ability of reader to decode Industrial 2 of 5 labels. $CU2EN00(CR) DEFAULT Industrial 2 of 5 = Disable $CU2EN01(CR) Industrial 2 of 5 = Enable Industrial 2 of 5 Check Character Calculation Enables/Disables calculation and verification of an optional Industrial 2 of 5 check character.
Enter/Exit Programming Mode 1D Code Selection Industrial 2 of 5 Check Character Transmission Enables/disables transmission of an Industrial 2 of 5 check character. $CU2CT00(CR) Industrial 2 of 5 Check Character Transmission = Disable $CU2CT01(CR) DEFAULT Industrial 2 of 5 Check Character Transmission = Enable Industrial 2 of 5 Length Control This feature specifies either variable length decoding or fixed length decoding for the Industrial 2 of 5 symbology.
1D Code Selection Enter/Exit Programming Mode Industrial 2 of 5 Set Length 1 This feature specifies one of the barcode lengths for Industrial 2 of 5 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the barcode’s data characters only. The length can be set from 0 to 50 characters. Table 11 provides some examples for setting Length 1. See page 193 if you want detailed instructions on setting this feature.
Enter/Exit Programming Mode 1D Code Selection Industrial 2 of 5 Set Length 2 This feature specifies one of the barcode lengths for Industrial 2 of 5 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the barcode’s check, data, and full-ASCII shift characters. The length does not include start/stop characters. The length can be set from 1 to 50 characters.
1D Code Selection Enter/Exit Programming Mode CODE IATA The following options apply to the IATA symbology. IATA Enable/Disable Enables/Disables the ability of the reader to decode IATA labels. $CIAEN00(CR) DEFAULT IATA = Disable $CIAEN01(CR) IATA = Enable IATA Check Character Transmission Enables/Disables calculation and verification of an optional Industrial 2 of 5 check character.
Enter/Exit Programming Mode 1D Code Selection CODABAR The following options apply to the Codabar symbology. Codabar Enable/Disable When disabled, the reader will not read Codabar barcodes. $CCBEN00(CR) DEFAULT Codabar = Disable $CCBEN01(CR) Codabar = Enable Codabar Check Character Calculation Enable this option to enables/disables calculation and verification of an optional Codabar check character.
1D Code Selection Enter/Exit Programming Mode Codabar Check Character Transmission Enable this option to transmit the check character along with Codabar barcode data. $CCBCT00(CR) Codabar Check Character Transmission = Don’t Send $CCBCT01(CR) DEFAULT Codabar Check Character Transmission = Send Codabar Start/Stop Character Transmission Enable this option to enable/disable transmission of Codabar start and stop characters.
Enter/Exit Programming Mode 1D Code Selection Codabar Start/Stop Character Set This option specifies the format of transmitted Codabar start/stop characters. $CCBSC00(CR) Codabar Check Character Set = ABCD/TN*E $CCBSC01(CR) Codabar Check Character Set = ABCD/ABCD $CCBSC02(CR) Codabar Check Character Set = abcd/tn*e $CCBSC03(CR) DEFAULT Codabar Check Character Set = abcd/abcd Codabar Start/Stop Character Match When enabled, this option requires that start and stop characters match.
1D Code Selection Enter/Exit Programming Mode Codabar Quiet Zones Specifies the number of quiet zones for Codabar labels. Quiet zones are blank areas at the ends of a barcode and are typically 10 times the width of the narrowest bar or space in the label.
Enter/Exit Programming Mode 1D Code Selection Codabar Set Length 1 This feature specifies one of the barcode lengths for Codabar Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the barcode’s start, stop, check and data characters. The length must include at least one data character. The length can be set from 3 to 50 characters. Table 13 provides some examples for setting Length 1.
1D Code Selection Enter/Exit Programming Mode Codabar Set Length 2 This feature specifies one of the barcode lengths for Codabar Length ControlCodabar Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. The length includes the barcode’s start, stop, check and data characters. The length must include at least one data character. The length can be set from 3 to 50 characters.
Enter/Exit Programming Mode 1D Code Selection ABC CODABAR The following options apply to the ABC Codabar symbology. ABC Codabar Enable/Disable Enables/Disables ability of reader to decode ABC Codabar labels. $CCBAB00(CR) DEFAULT ABC Codabar = Disable $CCBAB01(CR) ABC Codabar = Enable ABC Codabar Concatenation Mode Specifies the concatenation mode between Static and Dynamic.
1D Code Selection Enter/Exit Programming Mode ABC Codabar Dynamic Concatenation Timeout Specifies the timeout in 10-millisecond ticks used by the ABC Codabar Dynamic Concatenation Mode.
Enter/Exit Programming Mode 1D Code Selection ABC Codabar Force Concatenation Forces labels starting or ending with D to be concatenated.
1D Code Selection Enter/Exit Programming Mode CODE 11 The following options apply to the Code 11 symbology. Code 11 Enable/Disable When disabled, the reader will not read Code 11 barcodes. $CC1EN00(CR) DEFAULT Code 11 = Disable $CC1EN01(CR) Code 11 = Enable Code 11 Check Character Calculation This option enables/disables calculation and verification of optional Code 11 check character.
Enter/Exit Programming Mode 1D Code Selection Code 11 Check Character Transmission This feature enables/disables transmission of an optional Code 11 check character. $CC1CT00(CR) Code 11 Check Character Transmission = Don’t Send $CC1CT01(CR) DEFAULT Code 11 Check Character Transmission = Send Code 11 Length Control This feature specifies either variable length decoding or fixed length decoding for the Code 11 symbology.
1D Code Selection Enter/Exit Programming Mode Code 11 Set Length 1 This feature specifies one of the barcode lengths for Code 11 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the barcode’s check and data characters. The length can be set from 2 to 50 characters. Table 15 provides some examples for setting Length 1. See page 193 for detailed instructions on setting this feature. Table 15.
Enter/Exit Programming Mode 1D Code Selection Code 11 Set Length 2 This feature specifies one of the barcode lengths for Code 11 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the barcode’s check and data characters. The length can be set from 2 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length). Table 16 provides examples for setting Length 2.
1D Code Selection Enter/Exit Programming Mode GS1 DATABAR™ OMNIDIRECTIONAL The following options apply to the GS1 DataBar™ Omnidirectional (formerly RSS-14) symbology. GS1 DataBar™ Omnidirectional Enable/Disable When disabled, the reader will not read GS1 DataBar™ Omnidirectional barcodes.
Enter/Exit Programming Mode 1D Code Selection GS1 DataBar™ Omnidirectional 2D Component This feature enables/disables a requirement that a 2D label component be decoded when a base label for this symbology is decoded.
1D Code Selection Enter/Exit Programming Mode GS1 DataBar™ Expanded GS1-128 Emulation When enabled, GS1 DataBar™ Expanded barcodes will be translated to the GS1-128 label data format. $CXBU800(CR) DEFAULT GS1 DataBar™ Expanded GS1-128 Emulation = Disable $CXBU801(CR) GS1 DataBar™ Expanded GS1-128 Emulation = Enable GS1 DataBar™ Expanded 2D Component This feature enables/disables a requirement that a 2D label component be decoded when a base label of this symbology is decoded.
Enter/Exit Programming Mode 1D Code Selection GS1 DataBar™ Expanded Length Control This feature specifies either variable length decoding or fixed length decoding for the GS1 DataBar™ Expanded symbology. Variable Length: For variable-length decoding, a minimum length may be set. Fixed Length: For fixed-length decoding, two different lengths may be set.
1D Code Selection Enter/Exit Programming Mode GS1 DataBar™ Expanded Set Length 1 This feature specifies one of the barcode lengths for GS1 DataBar™ Expanded Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the barcode’s data characters only. The length can be set from 1 to 74 characters. Table 17 provides some examples for setting Length 1. See page 193 for detailed instructions on setting this feature.
Enter/Exit Programming Mode 1D Code Selection GS1 DataBar™ Expanded Set Length 2 This feature specifies one of the barcode lengths for GS1 DataBar™ Expanded Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the barcode’s data characters only. The length can be set from 1 to 74 characters. A setting of 0 specifies to ignore this length (only one fixed length). Table 18 provides examples for setting Length 2.
1D Code Selection Enter/Exit Programming Mode GS1 DATABAR™ LIMITED The following options apply to the GS1 DataBar™ Limited (formerly RSS Limited) symbology. GS1 DataBar™ Limited Enable/Disable When disabled, the reader will not read GS1 DataBar™ Limited barcodes. $CLBEN00(CR) DEFAULT GS1 DataBar™ Limited = Disable $CLBEN01(CR) GS1 DataBar™ Limited = Enable GS1 DataBar™ Limited GS1-128 Emulation When enabled, GS1 DataBar™ Limited barcodes will be translated to the GS1-128 label data format.
Enter/Exit Programming Mode 1D Code Selection GS1 DataBar™ Limited 2D Component This feature enables/disables a requirement that a 2D label component be decoded when a base label of this symbology is decoded. $CLB2D00(CR) DEFAULT GS1 DataBar™ Limited 2D Component = Disable (2D component not required) $CLB2D01(CR) GS1 DataBar™ Limited 2D Component = 2D component must be decoded CODE 93 The following options apply to the Code 93 symbology.
1D Code Selection Enter/Exit Programming Mode Code 93 Check Character Calculation Enables/disables calculation and verification of an optional Code 93 check character.
Enter/Exit Programming Mode 1D Code Selection Code 93 Length Control This feature specifies either variable length decoding or fixed length decoding for the Code 93 symbology. Variable Length: For variable length decoding, a minimum and maximum length may be set. Fixed Length: For fixed length decoding, two different lengths may be set.
1D Code Selection Enter/Exit Programming Mode Code 93 Set Length 1 Specifies one of the barcode lengths for Code 93 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the barcode’s data characters only. The length can be set from 01 to 50 characters. Table 19 provides some examples for setting Length 1. See page 193 for detailed instructions on setting this feature. Table 19.
Enter/Exit Programming Mode 1D Code Selection Code 93 Set Length 2 This feature specifies one of the barcode lengths for Code 93 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the barcode’s check, data, and full-ASCII shift characters. The length does not include start/stop characters. The length can be set from 1 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length).
1D Code Selection Enter/Exit Programming Mode Code 93 Quiet Zones Enables/disables quiet zones for Code 93. $CC9LO02(CR) Code 93 Quiet Zones = Quiet Zones on two sides $CC9LO03(CR) DEFAULT Code 93 Quiet Zones = Small Quiet Zones on two sides MSI The following options apply to the MSI symbology. MSI Enable/Disable Enables/Disables ability of reader to decode MSI labels.
Enter/Exit Programming Mode 1D Code Selection MSI Check Character Calculation Enables/Disables calculation and verification of an optional MSI check character. $CMSCC00(CR) MSI Check Character Calculation = Disable $CMSCC01(CR) DEFAULT MSI Check Character Calculation = Enable Mod10 $CMSCC02(CR) MSI Check Character Calculation = Enable Mod11/10 $CMSCC03(CR) MSI Check Character Calculation = Enable Mod10/10 MSI Check Character Transmission Enables/disables transmission of an MSI check character.
1D Code Selection Enter/Exit Programming Mode MSI Length Control This feature specifies either variable length decoding or fixed length decoding for the MSI symbology. Variable Length: For variable length decoding, a minimum and maximum length may be set. Fixed Length: For fixed length decoding, two different lengths may be set.
Enter/Exit Programming Mode 1D Code Selection MSI Set Length 1 This feature specifies one of the barcode lengths for MSI Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the barcode’s data characters only. The length can be set from 01 to 50 characters. Table 21 provides some examples for setting Length 1. See page 193 for detailed instructions on setting this feature. Table 21.
1D Code Selection Enter/Exit Programming Mode MSI Set Length 2 This feature specifies one of the barcode lengths for MSI Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the barcode’s check, data, and full-ASCII shift characters. The length does not include start/stop characters. The length can be set from 1 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length).
Enter/Exit Programming Mode 1D Code Selection PLESSEY The following options apply to the Plessey symbology. Plessey Enable/Disable Enables/Disables ability of reader to decode Plessey labels. $CPLEN00CR) DEFAULT Plessey = Disable $CPLEN01CR) Plessey = Enable Plessey Check Character Calculation Enables/Disables calculation and verification of an optional Plessey check character.
1D Code Selection Enter/Exit Programming Mode Plessey Check Character Transmission Enables/disables transmission of an MSI check character. $CPLCT00(CR) Plessey Check Character Transmission = Disable $CPLCT01(CR) DEFAULT Plessey Check Character Transmission = Enable Plessey Length Control This feature specifies either variable length decoding or fixed length decoding for the Plessey symbology. Variable Length: For variable length decoding, a minimum and maximum length may be set.
Enter/Exit Programming Mode 1D Code Selection Plessey Set Length 1 This feature specifies one of the barcode lengths for Plessey Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the barcode’s data characters only. The length can be set from 01 to 50 characters. Table 23 provides some examples for setting Length 1. See page 193 for detailed instructions on setting this feature. Table 23.
1D Code Selection Enter/Exit Programming Mode Plessey Set Length 2 This feature specifies one of the barcode lengths for Plessey Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the barcode’s check, data, and full-ASCII shift characters. The length does not include start/stop characters. The length can be set from 1 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length).
Enter/Exit Programming Mode 1D Code Selection NOTES 152 Programming Reference Guide
2D SYMBOLOGIES 2D Global Features • • 2D Maximum Decoding Time on page 154 2D Structured Append on page 155 • 2D Normal/Inverse Symbol Control on page 155 The reader supports the following 2D symbologies (barcode types). Symbology-dependent options for each symbology are included in this chapter. See "1D Code Selection" starting on page 61 for configuration of 1D barcodes.
Enter/Exit Programming Mode 2D Global Features 2D Maximum Decoding Time This feature specifies the maximum amount of time the software will spend attempting to decode a 2D label. The selectable range is 10 milliseconds to 2.55 milliseconds.
2D Global Features Enter/Exit Programming Mode 2D Structured Append Enables/disables ability of reader to append multiple 2D Codes labels in a structured format.
Enter/Exit Programming Mode Aztec Code SYMBOLOGY SELECTION Aztec Code Aztec Code Enable / Disable Enables/disables the ability of the reader to decode Aztec Code labels. $CAZEN00(CR) DEFAULT Aztec Code = Disable $CAZEN01(CR) Aztec Code = Enable Aztec Code Length Control This feature specifies either variable length decoding or fixed length decoding for this symbology. Variable Length: For variable length decoding, a minimum and maximum length may be set.
Aztec Code Enter/Exit Programming Mode Aztec Code Set Length 1 Specifies one of the barcode lengths for Aztec Code Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Characters can be set from 0001 to 3,832 characters in increments of 0001 (pad with zeroes). See page 193 for detailed instructions on setting this feature.
Enter/Exit Programming Mode Aztec Code Aztec Code Set Length 2 This feature specifies one of the barcode lengths for Aztec Code Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Characters can be set from 0001 to 3,832 characters in increments of 0001 (pad with zeroes). See page 193 for detailed instructions on setting this feature.
China Sensible Code Enter/Exit Programming Mode China Sensible Code China Sensible Code Enable / Disable Enables/disables the ability of the reader to decode China Sensible Code labels. $CCSEN00(CR) DEFAULT China Sensible Code = Disable $CCSEN01(CR) China Sensible Code = Enable China Sensible Code Length Control This feature specifies either variable length decoding or fixed length decoding for this symbology. Variable Length: For variable length decoding, a minimum and maximum length may be set.
Enter/Exit Programming Mode China Sensible Code China Sensible Code Set Length 1 Specifies one of the barcode lengths for China Sensible Code Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Characters can be set from 0001 to 7,827 characters in increments of 0001 (pad with zeroes). See page 193 for detailed instructions on setting this feature.
China Sensible Code Enter/Exit Programming Mode China Sensible Code Set Length 2 This feature specifies one of the barcode lengths for China Sensible Code Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Characters can be set from 0001 to 7,827 characters in increments of 0001 (pad with zeroes). See page 193 for detailed instructions on setting this feature.
Enter/Exit Programming Mode Data Matrix Data Matrix Data Matrix Enable / Disable Enables/disables ability of reader to decode Data Matrix labels. $CDMEN00(CR) Data Matrix = Disable $CDMEN01(CR) DEFAULT Data Matrix = Enable Data Matrix Square/Rectangular Style Specifies the options available when reading Data Matrix with different form factors.
Data Matrix Enter/Exit Programming Mode Data Matrix Length Control This feature specifies either variable length decoding or fixed length decoding for this symbology. Variable Length: For variable length decoding, a minimum and maximum length may be set. Fixed Length: For fixed length decoding, two different lengths may be set.
Enter/Exit Programming Mode Data Matrix Data Matrix Set Length 2 This feature specifies one of the barcode lengths for Data Matrix Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Characters can be set from 0001 to 3,116 characters in increments of 0001 (pad with zeroes). See page 193 for detailed instructions on setting this feature.
Maxicode Enter/Exit Programming Mode Maxicode Maxicode Enable / Disable Enables/disables ability of reader to decode Maxicode labels. $CMXEN00(CR) DEFAULT Maxicode = Disable $CMXEN01(CR) Maxicode = Enable Maxicode Primary Message Transmission Enables/disables the transmission of only the Primary Message when the Secondary Message is not readable.
Enter/Exit Programming Mode Maxicode Maxicode Length Control This feature specifies either variable length decoding or fixed length decoding for this symbology. Variable Length: For variable length decoding, a minimum and maximum length may be set. Fixed Length: For fixed length decoding, two different lengths may be set.
Maxicode Enter/Exit Programming Mode Maxicode Set Length 2 This feature specifies one of the barcode lengths for Maxicode Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Characters can be set from 0001 to 0145 characters in increments of 0001 (pad with zeroes). See page 193 for detailed instructions on setting this feature.
Enter/Exit Programming Mode PDF417 PDF417 PDF417 Enable / Disable Enables/disables the ability of the reader to decode PDF417 labels. $CP4EN00(CR) PDF417 = Disable $CP4EN01(CR) DEFAULT PDF417 = Enable PDF417 Length Control This feature specifies either variable length decoding or fixed length decoding for this symbology. Variable Length: For variable length decoding, a minimum and maximum length may be set. Fixed Length: For fixed length decoding, two different lengths may be set.
PDF417 Enter/Exit Programming Mode PDF417 Set Length 1 Specifies one of the barcode lengths for PDF417 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the barcode’s data characters only. Characters can be set from 0001 to 2,710 characters (pad with zeroes) in increments of 01. Any value greater than 2,710 will be considered to be 2,710. See page 193 for detailed instructions on setting this feature.
Enter/Exit Programming Mode PDF417 PDF417 Set Length 2 This feature specifies one of the barcode lengths for PDF417 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the barcode’s check, data, and full-ASCII shift characters. The length does not include start/stop characters. Characters can be set from 01 to 2,710 characters (pad with zeroes) in increments of 01.
Micro PDF417 Enter/Exit Programming Mode Micro PDF417 Micro PDF417 Enable / Disable Enables/disables the ability of the reader to decode Micro PDF417 labels. $CMIEN00(CR) DEFAULT Micro PDF417 = Disable $CMIEN01(CR) Micro PDF417 = Enable Micro PDF417 Code 128 GS1-128 Emulation Specifies which AIM ID to use for MicroPDF labels when doing Code 128 or GS1-128 emulation.
Enter/Exit Programming Mode Micro PDF417 Micro PDF417 Length Control This feature specifies either variable length decoding or fixed length decoding for this symbology. Variable Length: For variable length decoding, a minimum and maximum length may be set. Fixed Length: For fixed length decoding, two different lengths may be set.
Micro PDF417 Enter/Exit Programming Mode Micro PDF417 Set Length 2 This feature specifies one of the barcode lengths for Micro PDF417 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length includes the barcode’s data characters only. Characters can be set from 0001 to 0366 characters (pad with zeroes) in increments of 01. Any value greater than 0366 will be considered to be 0366.
Enter/Exit Programming Mode QR Code QR Code QR Code Enable / Disable Enables/disables the ability of the reader to decode QR Code labels. $CQREN00(CR) QR Code = Disable $CQREN01(CR) DEFAULT QR Code = Enable QR Code Length Control This feature specifies either variable length decoding or fixed length decoding for this symbology. Variable Length: For variable length decoding, a minimum and maximum length may be set. Fixed Length: For fixed length decoding, two different lengths may be set.
QR Code Enter/Exit Programming Mode QR Code Set Length 1 Specifies one of the barcode lengths for QR Code Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Characters can be set from 0001 to 7,089 characters in increments of 0001 (pad with zeroes). See page 193 for detailed instructions on setting this feature.
Enter/Exit Programming Mode QR Code QR Code Set Length 2 This feature specifies one of the barcode lengths for QR Code Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Characters can be set from 0001 to 7,089 characters in increments of 0001 (pad with zeroes). See page 193 for detailed instructions on setting this feature.
Micro QR Code Enter/Exit Programming Mode Micro QR Code Micro QR Code Enable/Disable Enables/disables the ability of the reader to decode Micro QR Code labels. MQEN00 DEFAULT Micro QR Code = Disable MQEN01 Micro QR Code = Enable Micro QR Code Length Control This feature specifies either variable length decoding or fixed length decoding for this symbology. Variable Length: For variable length decoding, a minimum and maximum length may be set.
Enter/Exit Programming Mode Micro QR Code Micro QR Code Set Length 1 Specifies one of the barcode lengths for Micro QR Code Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Characters can be set from 0001 to 0035 characters in increments of 0001 (pad with zeroes). See page 193 for detailed instructions on setting this feature.
Micro QR Code Enter/Exit Programming Mode Micro QR Code Set Length 2 This feature specifies one of the barcode lengths for Micro QR Code Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Characters can be set from 0001 to 0035 characters in increments of 0001 (pad with zeroes). See page 193 for detailed instructions on setting this feature.
Enter/Exit Programming Mode UCC Composite UCC Composite UCC Composite Enable / Disable Enables/disables the ability of the reader to decode the stacked part of a UCC Composite label. This feature is not effective when Global AIM IDs are enabled (see "Global AIM ID" on page 37).
UCC Composite UCC Optional Composite Timer Specifies the amount of time the system will wait for the stacked part of a UCC Composite label before transmitting the linear label without an add-on.
Postal Code Selection Postal Code Selection Enables/disables the ability of the scanner to decode labels of a specific postal symbology.
Postal Code Selection Postal Code Selection (continued) $CPOEN06(CR) Postal Code Selection = Enable Japan Post $CPOEN07(CR) Postal Code Selection = Enable IMB $CPOEN08(CR) Postal Code Selection = Enable Sweden Post $CPOEN09(CR) Postal Code Selection = Enable Portugal Post Postnet BB Control Controls the ability of the scanner to decode B and B' fields of Postnet labels.
Postal Code Selection NOTES 184 Programming Reference Guide
Chapter 4 References This section contains explanations and examples of selected barcode features. See Configuration Using Barcodes, starting on page 9 for the actual barcode labels used to configure the reader.
References USB COM Parameters Intercharacter Delay This parameter specifies the intercharacter delay between the end of one character and the beginning of the next. The delay can be set within a range of zero (0) to 990 milliseconds in 10ms increments. A setting of zero specifies no delay. To set the delay: 1. Determine the desired setting in milliseconds. 2. Divide the desired setting by 10 (setting is in 10ms increments). Pad the result with leading zeroes to yield two digits.
USB COM Parameters ACK NAK Options This enables/disables the ability of the reader to support the RS-232 ACK/NAK protocol. When configured, the reader and/or host sends an “ACK” when it receives data properly, and sends “NAK” when the data is in error. Options are: • Disable • Enable for label transmission — The reader expects an ACK/NAK response from the host when a label is sent. • Enable for host-command acknowledge — The reader will respond with ACK/NAK when the host sends a command.
References NAK Character This setting specifies an ASCII character or hex value to be used as the NAK character. ASCII characters or any hex value from 0 to 0xFF can be selected. To set this feature: 1. Determine the desired character or value. 2. Use the ASCII Chart on the inside back cover of this manual to find the hex equivalent for the desired character/value. 3. Go to page 17 and scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 4. Scan the barcode: SELECT NAK CHARACTER SETTING.
USB COM Parameters ACK NAK Timeout Value This option specifies the amount of time the reader waits for an ACK character from the host following label transmission. The selectable timeout range is 200 milliseconds to 15,000ms (15 seconds) in 200ms increments. A selection of 0 disables the timeout. To set this value: 1. Determine the desired setting in milliseconds. 2. Divide the desired setting by 200 (setting is in 200ms increments). Pad the result with leading zeroes to yield two digits.
References ACK NAK Retry Count This feature specifies the number of times the reader retries a label transmission due to a retry condition. The selectable range is from 1 to 254 retries. A selection of 0 disables the count, and a selection of 255 specifies unlimited retries. To set this feature: 1. Determine the desired setting. 2. Pad the number with leading zeroes to yield three digits. For example: 0 = 000, 5 = 005, 20 = 020, etc. 3.
USB COM Parameters Disable Character Specifies the value of the USB-COM host command used to disable the reader. ASCII characters or any hex value from 0 to 0xFF can be selected. To set the value: 1. Determine the desired character or value. A setting of 0xFF indicates the Disable Character is not used (not available). 2. Use the ASCII Chart on the inside back cover of this manual to find the hex equivalent for the desired character/value. 3.
References Enable Character Specifies the value of the USB-COM host command used to enable the reader. ASCII characters or any hex value from 0 to 0xFF can be selected. To set this feature: Determine the desired character or value. A setting of 0xFF indicates the Enable Character is not used (not available). 1. Determine the desired character or value. 2. Use the ASCII Chart on the inside back cover of this manual to find the hex equivalent for the desired character/value. 3.
Symbologies Symbologies Set Length Length Control allows you to select either variable length decoding or fixed length decoding for the specified symbology. Variable Length: For variable length decoding, a minimum and maximum length may be set. Fixed Length: For fixed length decoding, two different lengths may be set. Set Length 1 This feature specifies one of the barcode lengths for Length Control.
References 4. Scan the appropriate two digits from the keypad in Appendix D, Keypad that represent the length setting which was determined in the steps above. You will hear a two-beep indication after the last character. If you make a mistake, before the last character scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. 5. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode. This completes the procedure.
Data Editing Please Keep In Mind... • • • • Modifying a message string is not a mandatory requirement. Data editing is a sophisticated feature allowing highly customizable output for advanced users. Factory default settings for data editing is typically set to NONE. A prefix or suffix may be applied only to a specified symbology (reference 1D Code Selection, starting on page 61) or across all symbologies (set via the Global features in this chapter).
References Global AIM ID This feature enables/disables addition of AIM IDs for all symbology types. AIM label identifiers (as opposed to custom characters you select yourself as with label identifiers) can be included with scanned barcode data. AIM label identifiers consist of three characters as follows: • A close brace character (ASCII ‘]’), followed by... • A code character (see the table below), followed by... • A modifier character (the modifier character is symbol dependent).
Data Editing Label ID A Label ID is a customizable code of up to three ASCII characters (each can be one of hex 0x01-0xFF), used to identify a barcode (symbology) type. It can be appended previous to or following the transmitted barcode data depending upon how this option is enabled. This feature provides options for configuring custom Label IDs as a pre-loaded set (see "Label ID: Pre-loaded Sets" below) or individually per symbology (see "Label ID: Set Individually Per Symbology" on page 200).
References USA Label ID set Symbology EU Label ID set Default Character Default ASCII Default Character Default ASCII DATABAR 14 R4 523400 u 750000 DATABAR 14 COMPOSITE R4 523400 c 523400 DATABAR EXPANDED RX 525800 t 740000 DATABAR EXPANDED COMPOSITE RX 525800 d 525800 DATABAR LIMITED RL 524C00 v 760000 DATABAR LIMITED COMPOSITE RL 524C00 i 524C00 DATA MATRIX Dm 446D00 w 770000 EAN128 000000 k 6B0000 EAN128 COMPOSITE 000000 $E 244500 EAN13 F 460000 B 4200
Data Editing USA Label ID set Symbology MATRIX 2OF5 Default Character EU Label ID set Default ASCII Default Character Default ASCII g MAXICODE MC 4D4300 x 780000 MICRO QR $Q 245100 $Q 245100 MICRO PDF mP 6D5000 8 380000 MSI @ 400000 Z 5A0000 PDF417 P 500000 r 720000 PLESSEY a 610000 a 610000 POSTAL AUSTRALIAN $K 244B00 $K 244B00 POSTAL IMB $V 245600 $V 245600 POSTAL JAPANESE $R 245200 $R 245200 POSTAL KIX $U 245500 $U 245500 POSTAL PLANET $W 245700
References Label ID: Set Individually Per Symbology To configure a Label ID individually for a single symbology: 1. Go to page 37 and scan the ENTER/EXIT barcode. 2. Select Label ID position as either BEFORE (Enable as Prefix) or AFTER (Enable as suffix) by scanning the appropriate barcode in the section "Label ID Control" on page 37. Reference Figure 4 for Label ID positioning options if multiple identification features are enabled. 3.
Data Editing Table 33. Label ID Examples STEP ACTION EXAMPLES 1. Scan the ENTER/EXIT barcode (Scanner enters Programming Mode) 2. Determine placement of the Label ID characters BEFORE or AFTER with regard to scanned Enable as Prefix data using Label ID Control, starting on page 37 Enable as Suffix Enable as Prefix Enable as Suffix 3.
References Character Conversion Character conversion is an eight byte configuration item. The eight bytes are 4 character pairs represented in hexadecimal ASCII values. The first character in the pair is the character that will be converted. The second character in the pair is the character to convert to. If the character to convert in a pair is FF, then no conversion is done.
Scanning Features Scanning Features Scan Mode This mode is associated with typical handheld reader operation. Selects the scan operating mode for the reader.
References Stand Mode Off Time This feature specifies the amount of time reader illumination stays off after pulling the trigger when in Stand Mode. The configurable range is 01 to 32 by 01 in increments of 500ms (500ms to 16 seconds). Follow these instructions to set this feature: 1. Determine the desired setting. 2. Pad the result with leading zeroes to yield two digits. For example: 2 = 02, 5 = 05, 20 = 20, etc. 3. Go to page 53 and scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode.
Scanning Features Scanning Active Time This setting specifies the amount of time that the reader stays in scan ON state once the state is entered. The range for this setting is from 1 to 255 seconds in 1-second increments. Follow these instructions to set this feature: 1. Determine the desired setting. 2. Pad the result with leading zeroes to yield three digits. For example: 0 = 000, 5 = 005, 20 = 020, etc. 3. Go to page 53 and scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 4.
References Aiming Duration Time Specifies the frame of time the aiming pointer remains on after decoding a label, when in trigger single mode. The range for this setting is from 1 to 255 seconds in 1-second increments. Follow these instructions to set this feature: 1. Determine the desired setting. 2. Pad the result with leading zeroes to yield three digits. For example: 0 = 000, 5 = 005, 20 = 020, etc. 3. Go to page 56 and scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 4.
Scanning Features Flash On Time This feature specifies the ON time for the indicator LED while in Flash Mode. The selectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond increments. Follow these instructions to set this feature. 1. Determine the desired setting in milliseconds. 2. Divide the desired setting by 100 (setting is in 100ms increments). Pad the result with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc. 3.
References Flash Off Time This feature specifies the OFF time for the indicator LED while in Flash Mode. The selectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond increments. Follow these instructions to set this feature. 1. Determine the desired setting in milliseconds. 2. Divide the desired setting by 100 (setting is in 100ms increments). Pad the result with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc. 3.
Scanning Features Multiple Labels Ordering by Code Symbology This feature Specifies the transmission ordering by symbology type, when Multiple Labels per Frame is enabled.Up to six symbologies can be selected. Zeroes must be added to pad the string to 12 characters if not using all six symbologies. The labels are ordered first as specified in the output mask.
References Table 40.
Appendix A Technical Specifications Table 41 contains Physical and Performance Characteristics, User Environment and Regulatory information. Table 41. Technical Specifications . Item Description DSE0420-HP Physical Characteristics Dimensions (without Beeper Board) Height 0.6"/14 mm Length 1.9"/47 mm Width 1.6"/40 mm Weight (without cable) Approximately 0.7 ounces/20 g Electrical Characteristics Input Voltage: 5.
Technical Specifications Optical Characteristics Key Parameters Parameter Optical Format Active Imager Size Active Pixels Illumination System Aiming System Tilt Tolerance Pitch Tolerance Skew Tolerance Field of View Value 1/3-inch 4.51mm(H) x 2.88mm(V) 5.35mm diagonal 752H x 480V LED source White emission (wavelength = 400-750 nm) IEC 62471 – EXEMPT RISK GROUP Laser source Red emission (wavelength = 630-680 nm) Pulsed source: maximum lamp duration 15ms, repetition rate 16.
Technical Specifications Quality and Reliability Test ID Test Description Dynamic Shock: 2000 G ± 5% applied via any mounting surface at -30º C and 70º C for a period of 0.85 ± 0.05 msec . 2500 G ± 5% applied via any mounting surface at 23º C for a period of 0.85 1 Shock ± 0.05 msec Vibration: 20 to 80 Hz 2 Environmental Ramp up at 0.04 G2/Hz at 3 dB/octave 80 to 350 Hz 0.4 G2/Hz 350 Hz to 2 kHz Ramp down at 0.
Technical Specifications Test ID 3 Test Radiated Emissions Description EN 55022 / 1998 CLASS B The Scan Engine must be shielded from ESD strikes up to ±15KV with the enclosure. 4 ESD To date, testing on the Imager Module has been performed at level of 2,5KV on the connector. The module was tested inside another host product up to 4Kv direct and 8KV air.
Appendix B Standard Defaults The most common configuration settings are listed in the “Default” column of the table below. Page references are also provided for feature descriptions and programming barcodes for each parameter. A column has also been provided for recording of your preferred default settings for these same configurable features. Table 42.
Standard Defaults Parameter USB Keyboard Speed Default Your Setting Page Number 1 ms 28 Standard Keys 29 No Global Prefix Global Suffix = 0x0D (CR) 32 Global AIM ID Disable 33 Set AIM ID Individually for GS1-128 Enable 35 Label ID: Pre-Loaded Sets EU Set 36 Individually Set Label ID Disable 37 Case Conversion Disable 43 No Char Conversion 44 0.
Standard Defaults Parameter Default Your Setting Page Number Aiming Off After Decoding 56 Green Spot Duration 300 ms 57 Mobile Phone Mode Enable 57 Partial Label Reading Control Enable 58 Decode Negative Image Disable 58 Disable 59 Random Order 60 Disable 60 Enable only UPCA coupon decoding 63 Enable 64 Send 64 Don’t Expand 65 Transmit 65 2D Component Not Required 66 Enable 66 Send 67 2D Component Not Required 67 Expand UPC-E to EAN-13 Don’t Expand 68 Expand UPC-
Standard Defaults Parameter GTIN Formatting Default Your Setting Page Number Disable 69 Enable 70 Send 70 EAN-13 Flag 1 Character Transmit 71 EAN-13 ISBN Conversion Disable 71 2D Component Not Required 72 Disable 72 Enable 73 Send 73 Disable 74 2D Component Not Required 74 Disable 75 Two Modules 76 Disable P2, P5 and P8 77 70 ms 78 Disable 81 Code 39 Enable/Disable Enable 84 Code 39 Check Character Calculation Disable 84 Send 85 Don’t Transmit 86 Code 39 Full
Standard Defaults Parameter Default Your Setting Page Number Code 39 Set Length 1 2 88 Code 39 Set Length 2 50 89 Disable 90 Disable 90 Don’t Send 91 Don’t Transmit 91 Disable 92 Code 39 Danish PPT Enable/Disable Disable 92 Code 39 LaPoste Enable/Disable Disable 93 Code 39 PZN Enable/Disable Disable 93 Enable 94 Don’t Expand 94 Code 128 Check Character Transmission Don’t Send 95 Code 128 Function Character Transmission Don’t Send 95 Small Quiet Zones on two sides 96
Standard Defaults Parameter ISBT 128 Concatenation Mode Default Your Setting Page Number Static 101 200 msec 102 I 2 of 5 Enable/Disable Disable 103 I 2 of 5 Check Character Calculation Disable 104 Send 105 Variable 105 I 2 of 5 Set Length 1 6 106 I 2 of 5 Set Length 2 50 107 Disable 108 Disable 108 Follett 2 of 5 Enable/Disable Disable 109 Standard 2 of 5 Check Character Calculation Disable 109 Send 110 Variable 110 Standard 2 of 5 Set Length 1 8 111 Standard 2 of 5
Standard Defaults Parameter IATA Check Character Transmission Default Your Setting Page Number Enable 117 Disable 118 Don’t Calculate 118 Send 119 Transmit 119 abcd/abcd 120 Codabar Start/Stop Character Match Don’t Require Match 120 Codabar Quiet Zones Small Quiet Zones on two sides 121 Variable 121 Codabar Set Length 1 3 122 Codabar Set Length 2 50 123 Disable 124 Disable 124 Static 124 200 msec 125 Disable 126 Disable 127 Check C and K 127 Send 128 Variable 1
Standard Defaults Parameter GS1 DataBar™ Omnidirectional 2D Component Default Your Setting Page Number 2D component not required 132 GS1 DataBar™ Expanded Enable/Disable Disable 132 GS1 DataBar™ Expanded GS1-128 Emulation Disable 133 GS1 DataBar™ Expanded 2D Component 2D component not required 133 GS1 DataBar™ Expanded Length Control Variable 134 GS1 DataBar™ Expanded Set Length 1 1 135 GS1 DataBar™ Expanded Set Length 2 74 136 GS1 DataBar™ Limited Enable/Disable Disable 137 GS1 D
Standard Defaults Parameter Default Your Setting Page Number Plessey Plessey Enable/Disable Disable 148 Enable Plessey std. check char.
Standard Defaults Parameter Default Your Setting Page Number PDF417 Enable / Disable Enable 168 PDF417 Length Control Variable 168 PDF417 Set Length 1 1 169 PDF417 Set Length 2 2,710 170 Disable 171 Micro PDF AIM ID and label type 171 Variable 172 Micro PDF417 Set Length 1 1 172 Micro PDF417 Set Length 2 0366 173 QR Code Enable / Disable Enable 174 QR Code Length Control Variable 174 QR Code Set Length 1 1 175 QR Code Set Length 2 7,089 176 Micro QR Code Enable/Disabl
Appendix C Sample Barcodes The sample barcodes in this appendix are typical representations for their symbology types.
Sample Barcodes Sample Barcodes (continued) Code 32 Codabar 13579 Code 93 Code 11 123456789 226 Programming Reference Guide
Sample Barcodes GS1 DataBar™ (RSS) GS1 DataBar™ variants must be enabled to read the barcodes below (see GS1 DataBar™ Omnidirectional on page 131).
Sample Barcodes 2D Barcodes Aztec Datamatrix China Sensible Code MaxiCode PDF 417 Micro PDF 417 ABCabc BV17453 QR Code Micro QR Code 123456 35900G9 UCC Composite 228 Programming Reference Guide
Appendix D Keypad Use the barcodes in this appendix to enter numbers as you would select digits/characters from a keypad.
Keypad 230 A B C D E F Programming Reference Guide
Appendix E Scancode Tables Control Character Emulation Control character emulation selects from different scancode tables as listed in this appendix. Each of the control character sets below are detailed by interface type in the tables. These apply to USB Keyboard platforms. Control Character 00 : Characters from 00 to 0x1F are sent as control character Ctrl+Keys, special keys are located from 0x80 to 0xA1.
Interface Type USB-Keyboard or USB-Keyboard for APPLE Table 43. Scancode Set When Control Character is 00 or 01 0x 1x x0 NULL C+@ DLE C(S)+P x1 SOH C(S)+A DC1 C(S)+Q x2 STX C(S)+B DC2 C(S)+R x3 ETX C(S)+C DC3 C(S)+S x4 EOT C(S)+D DC4 C(S)+T x5 ENQ C(S)+E NAK C(S)+U X6 ACK C(S)+F SYN C(S)+V x7 BEL C(S)+G ETB C(S)+W x8 BS CAN C(S)+X x9 HT TAB EM C(S)+Y xA LF C(S)+J SUB C(S)+Z xB VT C(S)+K ESC Esc xC FF C(S)+L FS C+\ xD CR Enter GS C+] xE SO C(S)+N RS C+^ xF SI C(S)+O US C(S)+_ 2x SP ! "
Interface Type USB-Keyboard or USB-Keyboard for APPLE (continued) Table 44. Scancode Set When Control Character is 02 0x x0 x1 x2 x3 x4 x5 X6 x7 x8 x9 xA xB Ar↓ Ar↑ Al↓ Al ↑ Cl ↓ Cl ↑ Cr ↓ Cr ↑ BS Tab S+ Tab Home F6 F1 F2 F3 F4 F5 F7 xD xE xF Enter Ins Pg Up 1x Pg Dwn 2x Space ! “ # $ % & ‘ ( ) * + , - .
Interface type USB-Keyboard Alt Mode Table 45.
Interface type USB-Keyboard Alt Mode (continued) Table 46.
Microsoft Windows Codepage 1252 Windows-1252 is a character encoding of the Latin alphabet, used by default in the legacy components of Microsoft Windows in English and some other Western languages.
ASCII Chart Table 1 ASCII Char. Hex No. ASCII Char. Hex No. ASCII Char. Hex No. ASCII Char. Hex No. NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F SP ! “ # $ % & ’ ( ) * + , .