HP Integrated Barcode Scanner HP Integrated Barcode Scanner Programming Reference Guide

Enter/Exit Programming Mode 1D Code Selection
98 Programming Reference Guide
Code 128 Set Length 2
This feature specifies one of the barcode lengths for Code 128 Length Control. Length 2 is the maximum label
length if in Set Length 2 Mode, or the second fixed length if in Set Length 1 Mode. Length includes the
barcode’s data characters only.
The length can be set from 1 to 80 characters. A setting of 0 specifies to ignore this length (only one fixed
length).
Table 6 provides examples for setting Length 2. See page 193 for detailed instructions on setting this feature.
Table 6. Code 128 Length 2 Setting Examples
.
STEP ACTION EXAMPLES
1 Desired Setting
00 (Ignore This
Length)
07 Characters 15 Characters 80 Characters
2 Scan ENTER/EXIT PROGRAMMING MODE
3 Scan SELECT CODE 128 LENGTH 2 SETTING
4
Scan Two Characters From
Appendix D, Keypad
‘0’ and ‘0’ ‘0’ and ‘7’ ‘1’ and ‘5’ ‘8’ and 0’
5 Scan ENTER/EXIT PROGRAMMING MODE
Select Code 128 Length 2 Setting
Make a mistake? Scan the CANCEL barcode to
abort and not save the entry string. You can then start
again at the beginning.
CANCEL
$CC8L2
~
DEFAULT
80 = Length 2 is 80 Characters