HP Integrated Barcode Scanner HP Integrated Barcode Scanner Programming Reference Guide
Enter/Exit Programming Mode 1D Code Selection
150 Programming Reference Guide
Plessey Set Length 1
This feature specifies one of the barcode lengths for Plessey Length Control. Length 1 is the minimum label
length if in Vari able Le ngth Mode, or the first fixed length if in Fixed Length Mode. Length includes the
barcode’s data characters only. The length can be set from 01 to 50 characters.
Table 23 provides some examples for setting Length 1. See page 193 for detailed instructions on setting this
feature.
Table 23. Plessey Length 1 Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting 01 Characters 07 Characters 15 Characters 50 Characters
2 Scan ENTER/EXIT PROGRAMMING MODE
3 Scan SELECT Plessey LENGTH 1 SETTING
4
Scan Two Characters From
Appendix D, Keypad
‘0’ and ‘1’ ‘0’ and ‘7’ ‘1’ and ‘5’ ‘5’ AND ‘0’
5 Scan ENTER/EXIT PROGRAMMING MODE
Select Plessey Set Length 1 Setting
Make a mistake? Scan the CANCEL barcode to
abort and not save the entry string. You can
then start again at the beginning.
CANCEL
$CPLL1
~
DEFAULT
01 = Length 1 is 1 Character