HP Integrated Barcode Scanner HP Integrated Barcode Scanner Programming Reference Guide
Enter/Exit Programming Mode QR Code
176 Programming Reference Guide
QR Code
Set Length 2
This feature specifies one of the barcode lengths for QR Code Length Control. Length 2 is the maximum label
length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Characters can be set
from 0001 to 7,089 characters in increments of 0001 (pad with zeroes).
See page 193 for detailed instructions on setting this feature.
Select QR Code Length 2 Setting
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE barcode above, then the barcode at
left followed by the digits from the Alphanumeric char-
acters in
Appendix D, Keypad representing your
desired character(s). End by scanning the ENTER/EXIT
barcode again.
Make a mistake? Scan the CANCEL barcode to
abort and not save the entry string. You can then start
again at the beginning.
CANCEL
$CQRL2
~
DEFAULT
Length 2 is 7,089 Characters