HP Integrated Barcode Scanner HP Integrated Barcode Scanner Programming Reference Guide

References
208 Programming Reference Guide
Flash Off Time
This feature specifies the OFF time for the indicator LED while in Flash Mode. The selectable range is 100 to
9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond increments.
Follow these instructions to set this feature.
1. Determine the desired setting in milliseconds.
2. Divide the desired setting by 100 (setting is in 100ms increments). Pad the result with leading zeroes to
yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
3. Go to page 55 and scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming
Mode.
4. Scan the barcode: SELECT FLASH OFF TIME SETTING.
5. Scan the appropriate two digits from the keypad in Appendix D, Keypad, that represent the duration
which was determined in the steps above. You will hear a two-beep indication after the last character.
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode.
This completes the procedure. See Table 38 for some examples of how to set this feature.
Table 38. Flash Off Time Setting Examples
If you make a mistake before the last character, scan the CANCEL barcode to abort and not save
the entry string. You can then start again at the beginning.
STEP ACTION EXAMPLES
1 Desired Setting
500ms 1,000ms (1 sec.) 5200ms (5.2 sec.) 9,900ms (9.9 sec.)
2
Divide by 100 (and pad with
leading zeroes to yield two
digits)
05 10 52 99
3 Scan ENTER/EXIT PROGRAMMING MODE
4 Scan SELECT FLASH OFF TIME SETTING
5
Scan Two Characters From
Appendix D, Keypad
‘0’ and ‘5’ ‘1’ and ‘0’ 5’ and ‘2’ ‘9’ and ‘9’
6 Scan ENTER/EXIT PROGRAMMING MODE