Installation Manual

14
Step3 Use a screwdriver to fasten the captive screws on the 2GE interface module.
Figure 12 Install a 2GE interface module
Installing an NSQ1GT2UA0 or NSQ1GP4U0 interface
module
The A-U200-A supports NSQ1GT2UA0 and NSQ1GP4U0 interface modules. The installation
procedure of the two interface modules are the same. This section takes an NSQ1GP4U0 interface
module for example. Follow these steps to install an NSQ1GP4U0 interface module:
Step1 Select the slot where you want to install the NSQ1GP4U0 interface module. Use a Philips screwdriver to
loosen the fastening screws on the filler panel, and remove the filler panel. The interface module can be
installed only in the lower slot.
Step2 Push the interface module slowly along the guide rails into the slot until it touches the slot bottom, as
shown in Figure 13.
Step3 Use a screwdriver to fasten the captive screws on the NSQ1GP4U0 interface module.
Figure 13 Install an NSQ1GP4U0 interface module