QuickSpecs HP ProLiant BL25p Server Blade Overview 42U Rack with HP ProLiant BL25p System Installed 1. BL p-Class interconnects (2) in HP BladeSystem p-Class server blade enclosure (interconnect switch shown) 2. HP ProLiant BL25p server blades (8) in HP BladeSystem p-Class server blade enclosure 3. HP BladeSystem p-Class 3U power enclosure with hot-plug power supplies (6) What's New Support for AMD Opteron 200 series Dual-Core processors Models 275 (2.2GHz), 270 (2.0GHz) and 265 (1.
QuickSpecs HP ProLiant BL25p Server Blade Overview At A Glance Performance dual processor server blade designed with enterprise availability HP ProLiant BL25p server blade includes: AMD Opteron 200 series single and dual-core processors (dual capability) Models 275 (2.2GHz), 270 (2.0GHz), 265 (1.8GHz), 252 (2.6GHz) and 250 (2.
QuickSpecs HP ProLiant BL25p Server Blade Overview HP ProLiant BL25p Server Blade + HP BladeSystem p-Class Server Blade Enclosure + DA - 12160 North America — Version 7 — June 27, 2005 Page 3
QuickSpecs HP ProLiant BL25p Server Blade Overview OR Patch Panel (shown) or Patch Panel 2 GbE Interconnect Switch (shown) or GbE2 Interconnect Switch or CGESM Interconnect Switch (fiber or copper-based) BL p-Class Interconnects + BL p-Class power enclosures and power supplies OR HP BladeSystem p-Class 1U power enclosure and power supplies OR Facility DC DA - 12160 North America — Version 7 — June 27, 2005 Page 4
QuickSpecs HP ProLiant BL25p Server Blade Overview OR OR Mini bus bar Bus boxes Scalable bus bar Dual power input kit for mini bus bar HP BladeSystem p-Class power distribution (only required with the 3U power enclosure) Configuration Steps For a complete configuration of the HP ProLiant BL25p server blade, do the following: 1. Select desired model, configuration and quantity of HP ProLiant BL25p server blades. PLUS 2.
QuickSpecs HP ProLiant BL25p Server Blade Overview HP BladeSystem p-Class Server Blade Enclosure Upgrade Kit (option)(354100-B21) NOTE: Server Blade Enclosure Upgrade Kit (354100-B21) contains enhanced backplane components and enables a field upgrade of a blade enclosure to support BL p-class blades and provide a single, physical iLO port for the enclosure. PLUS 3. Select an Interconnect Kit.
QuickSpecs HP ProLiant BL25p Server Blade Overview 1U power enclosure with two power supplies (380314-B21) NOTE: Additional power supplies can also be purchased separately - see options list below. PLUS 5.
QuickSpecs HP ProLiant BL25p Server Blade Standard Features (Server Blade) Processors AMD Opteron Model 252 processor 2.6 GHz/1 GHz - 1MB (single-core) AMD Opteron Model 250 processor 2.4 GHz/800 MHz - 1MB (single-core) AMD Opteron Model 265 processor 1.8GHz/1 GHz (dual-core) AMD Opteron Model 270 processor 2.0GHz/1 GHz (dual-core) AMD Opteron Model 275 processor 2.2GHz/1 GHz (dual-core) Upgradeability Upgradeable to dual processing.
QuickSpecs HP ProLiant BL25p Server Blade Standard Features (Server Blade) Fiber Channel on the The following items are needed to connect the HP ProLiant BL25p server blade to the SAN: HP ProLiant BL25p server 1.
QuickSpecs HP ProLiant BL25p Server Blade Standard Features (Server Blade Enclosure and Interconnects) HP BladeSystem p-Class Server Blade Enclosures and ProLiant BL p-Class Interconnects HP BladeSystem p-Class Server Blade Enclosures 6U (10.
QuickSpecs HP ProLiant BL25p Server Blade Standard Features (Server Blade Enclosure and Interconnects) The GbE2 Interconnect Kits (C-GbE2 and F-GbE2) are for applications that require network adapter consolidation to 1000 Mbps (Gigabit Ethernet) and HP ProLiant BL25p Fibre Channel pass-through.
QuickSpecs HP ProLiant BL25p Server Blade Standard Features (Server Blade Enclosure and Interconnects) ProLiant BL p-Class Storage Connectivity Kit Option (Supports two CGESM or GbE2 switches per kit) The Storage Connectivity Kit is used if HP ProLiant BL25p Fibre Channel signal pass-through is desired when using the CGESM or GbE2 Interconnect Switch. Therefore, both LAN cable consolidation and SAN connectivity is possible using a single interconnect option.
QuickSpecs HP ProLiant BL25p Server Blade Standard Features (Power System and Rack Information) HP BladeSystem p-Class Power System and Rack Information NOTE: To determine power configuration please refer to the HP BladeSystem p-Class Overview and Planning Whitepaper and sizing tool at http://h18000.www1.hp.com/products/servers/proliant-bl/pclass/20p/index.html. HP BladeSystem p-Class 3U Power Enclosure 3U (5.25-inch), 19-inch wide, 29-inch deep (0.48-meter wide, 0.
QuickSpecs HP ProLiant BL25p Server Blade Standard Features (Power System and Rack Information) Power Enclosures Supported Scalable Bus Bar Mini Bus Bar Power Bus Box 1 or 2 1 or 2 1 Server Blade Enclosures Supported up to 5 up to 3 1 Max. Rack Space Occupied 36U 21U 9U Dual power input kit for mini bus bar option (364565-B21) required to support two power enclosures. NOTE: To support a full 42U rack of BL p-Class server blades, use two stacked pairs of mini bus bars.
QuickSpecs HP ProLiant BL25p Server Blade Standard Features ProLiant Essentials ProLiant Essentials Rapid Foundation Pack Deployment Pack Software for the ProLiant BL Server Blades Rapid Deployment Pack (RDP) is an automated deployment and provisioning solution for all ProLiant servers. RDP includes the Altiris Deployment Solution and ProLiant Integration Module featuring ProLiant server pre-configured events for OS installation, and optimized software drivers, firmware and management agents.
QuickSpecs HP ProLiant BL25p Server Blade Standard Features Optional ProLiant Essentials Value Packs Optional software offerings that selectively extend the functionality of an Adaptive Infrastructure to address specific business problems and needs: Workload Management Pack - provides easier management of complex environments, improving overall server utilization and enabling Windows® 2000 customers for the first time to confidently deploy multiple applications on a single multiprocessor ProLiant Server.
QuickSpecs HP ProLiant BL25p Server Blade Standard Features OS Support: Dual-Core 1.8 GHz, 2.0 GHz and 2.
QuickSpecs HP ProLiant BL25p Server Blade Standard Features Availability Power redundancy: Redundant AC feeds into power enclosures, redundant DC feeds from power enclosure to server blade enclosures, N + N redundant power supplies Dual-Port Fibre Channel Mezzanine Card for redundant SAN connection Two hot-plug SCSI hard drive bays and integrated RAID (Smart Array 6i Plus) on every server blade (Battery-backed write cache is optional.
QuickSpecs HP ProLiant BL25p Server Blade Standard Features Minimum Rack Requirements Mounts in ProLiant, and Telco racks and Third Party racks that meet the following criteria: Compatible with 19-inch Standard EIA rail sets EIA rail-to-rail depth is 29 - 30" Cabinet depth must be at least 36-inch deep overall (Additional min. 3.
QuickSpecs HP ProLiant BL25p Server Blade Standard Features Service and Support Three-year limited warranty, including hardware diagnostic support, pre-failure warranty (coverage of hard drives, memory and processors). The warranty is fully supported by HP Services and a worldwide network of resellers and service providers. In addition 90-day's getting started software telephone support may be covered under the warranty or available for an additional fee.
QuickSpecs HP ProLiant BL25p Server Blade Models ProLiant BL25p 1.8GHz- Processor(s) 1MB,DC 1GB (1P) 392443-B21 Cache Memory Memory Network Adapter Storage Controller Hard Drives Internal Storage Optical Drive Form Factor ProLiant BL25p 2.0GHz- Processor(s) 1MB, DC 2GB (2P) 392441-B21 Cache Memory Memory Network Adapter Storage Controller Hard Drives Internal Storage Optical Drive Form Factor ProLiant BL25p 2.
QuickSpecs HP ProLiant BL25p Server Blade Models ProLiant BL25p 2.4GHz- Processor(s) 1MB, 1GB (1P) 374797-B21 Cache Memory Memory Network Adapter Storage Controller Hard Drives Internal Storage Optical Drive Form Factor ProLiant BL25p 2.6GHz- Processor(s) 1MB, 1GB (1P) 374798-B21 Cache Memory Memory Network Adapter Storage Controller Hard Drives Internal Storage Optical Drive Form Factor ProLiant BL25p 2.
QuickSpecs HP ProLiant BL25p Server Blade Configuration Information Factory Integrated Models NOTE: HP does not allow factory integration of options into standard models listed above. Configure-to-order servers must start with a CTO Chassis. NOTE: This product offering does not support HP Factory Express Server Configuration Level 1.
QuickSpecs HP ProLiant BL25p Server Blade Options ProLiant Essentials Value Pack Software ProLiant Essentials Vulnerability and Patch Management Pack, 1 Server + 10Desktop Bundle License ProLiant Essentials Vulnerability and Patch Management Pack, Single-Server License ProLiant Essentials Vulnerability and Patch Management Pack, 10-Server License ProLiant Essentials Vulnerability and Patch Management Pack, Flexible-Quantity License ProLiant Essentials Vulnerability and Patch Management Pack, Tracking Lic
QuickSpecs HP ProLiant BL25p Server Blade Options ProLiant Essentials Performance Management Pack, 10-Server License NOTE: For use with up to 10 servers. Contains 10 licenses with one unique license activation key and documentation. ProLiant Essentials Performance Management Pack, Flexible-Quantity License NOTE: For use with multiple servers. This part number can be used to purchase multiple licenses with a single activation key.
QuickSpecs HP ProLiant BL25p Server Blade Options Processor HP BL25p Opteron 2.2GHz-1M DC Processor Option Kit HP BL25p Opteron 2.0GHz-1M DC Processor Option Kit HP BL25p Opteron 1.8GHz-1M DC Processor Option Kit HP BL25p Opteron 2.6GHz-1M SC Processor Option Kit HP BL25p Opteron 2.
QuickSpecs HP ProLiant BL25p Server Blade Options HP BladeSystem p-Class Server Blade Enclosures HP BladeSystem p-Class Interconnects HP BladeSystem p-Class Server Blade Enclosure with enhanced backplane components and the HP BladeSystem Management Suite NOTE: Includes a HP BladeSystem p-Class Server Blade Enclosure with enhanced backplane components, a single copy of Systems Insight Manager (SIM) and 8 licenses for each of the following products: Rapid Deployment Pack (RDP), Performance Management Pack
QuickSpecs HP ProLiant BL25p Server Blade Options NOTE: Required for BL20P G3 Fibre Channel signal pass through when using the CGESM or GbE2 Interconnect Switch. NOTE: Only one Storage Connectivity Kit required per each GbE2 Interconnect Kit. NOTE: Only one Storage Connectivity Kit required for (2) CGESM Interconnect Kit.
QuickSpecs HP ProLiant BL25p Server Blade Options Power Distribution (only required with 3U power enclosures) HP BladeSystem p-Class Scalable Bus Bar HP BladeSystem p-Class Mini Bus Bar HP BladeSystem p-Class Bus Power Box Dual Power Input Kit for Mini Bus Bar HP Modular Distribution Unit 40 Amp HP Modular Distribution Unit 24 Amp NOTE: The Modular Distribution Unit Kits excludes the extension bars as they are not required with the HP BladeSystem p-class 1U power enclosure.
QuickSpecs HP ProLiant BL25p Server Blade Options MSL6030, 1 drive, 30 slots, Ultrium 460 MSL6030, 2 drive, 30 slots, Ultrium 460 MSL6030, 1 drive, 30 slots, Ultrium 460, with embedded FC router MSL6030, 2 drive, 30 slots, Ultrium 460, with embedded FC router MSL6060, 2 drive, 60 slot Ultrium 460, with embedded FC router NOTE: Please reference the MSL6000 Tape Library QuickSpecs at http://www.hp.
QuickSpecs HP ProLiant BL25p Server Blade Options Ultra Density Optical Jukeboxes 1000ux, 2 drive, 32 slot jukebox 1900ux, 4 drive, 64 slot jukebox 1900ux, 4 mixed drive, 64 slot jukebox 2300ux, 2 drive, 76 slot jukebox 3800ux, 4 drive, 128 slot jukebox 3800ux, 6 drive, 128 slot jukebox 7100ux, 4 drive, 238 slot jukebox 7100ux, 6 drive, 238 slot jukebox 7100ux, 10 drive, 238 slot jukebox 7100ux, 6 mixed drive, 238 slot jukebox NOTE: Please reference the Ultra Density Optical Jukebox QuickSpecs at http://
QuickSpecs HP ProLiant BL25p Server Blade Options HP StorageWorks Modular Smart Array 1000 HP StorageWorks Modular Smart Array 1000 Modular Smart Array 1000 Controller Modular Smart Array Fibre Channel I/O Module Modular Smart Array hub 2/3 HP StorageWorks Modular Smart Array 1000 NOTE: Please see the StorageWorks Modular Smart Array 1000 QuickSpecs for additional options and configuration information at: http://h18000.www1.hp.com/products/quickspecs/11033_na/11033_na.
QuickSpecs HP ProLiant BL25p Server Blade Options Rack 10000 Series (Graphite Metallic) Rack Options for HP Rack 10000 Series Rack, HP Infrastructure 42U (HV) Rack, HP Infrastructure 42U (LV) HP Rack 10842 (42U) - Pallet HP Rack 10842 (42U) - Shock Pallet HP S10614 (14U) Rack Cabinet - Shock Pallet HP Rack 10647 (47U) Cabinet - Pallet HP Rack 10647 (47U) Cabinet - Crated HP Rack 10642 (42U) Cabinet - Pallet HP Rack 10642 (42U) Cabinet - Shock Pallet HP Rack 10642 (42U) Cabinet - Crated HP Rack 10636 (36
QuickSpecs HP ProLiant BL25p Server Blade Options HP KVM Switch Options IP Console Switch Box (KVM/IP), 1 x 1 x 16 IP Console Switch Box (KVM/IP) , 3 x 1 x 16 Serial Interface adapter - 1 Pack with power supply Interface adapter - USB 1.0 (single pack) CAT5e Cable 3', 4 pack CAT5e Cable 6', 8 pack CAT5e Cable 12', 8 pack CAT5e Cable 20', 4 pack CAT5e Cable 40', 1 pack NOTE: For additional information regarding HP KVM Switches and options, please see the following URL: http://h18004.www1.hp.
QuickSpecs HP ProLiant BL25p Server Blade Options Installation & Start-up Services ProLiant BL p-Class Blade Server Hardware Installation ProLiant BL p-Class Blade Server Hardware Installation, Electronic ProLiant BL p-Class Enclosure and Server Blade Hardware Installation ProLiant BL p-Class Enclosure and Server Blade Hardware Installation, Electronic Provides for the Installation and Start-up of ProLiant Essentials Rapid Deployment Pack on a Customer supplied server designated as a Deployment Server.
QuickSpecs HP ProLiant BL25p Server Blade Memory HP ProLiant BL25p Server Blade (2P Models) Standard Memory 2048-MB PC3200 Registered DDR SDRAM DIMM installed (4 x 512MB SDRAM DIMM) Standard Memory Plus Optional Memory Up to 10240-MB of DDR SDRAM DIMM memory is available with the installation of optional DDR SDRAM DIMM memory expansion kits.
QuickSpecs HP ProLiant BL25p Server Blade Technical Specifications HP BladeSystem p-Class Server Blade Enclosure Dimensions Height 10.5 in (26.67 cm) Width 17.60 in (44.70 cm) Depth 28.86 in (73.30 cm) Input Specifications Rated input voltage -43 VDC to -53 VDC Nominal -48 VDC Rated input current 62.5 A at -48 VDC Rated input Power 3000 W Individual Server Blade Rated input voltage -43 VDC to -53 VDC Nominal -48 VDC Bay Ratings Rated input current 6.
QuickSpecs HP ProLiant BL25p Server Blade Technical Specifications Operating and Performance Specifications for RJ-45 Patch Panel 2 with Fiber Channel pass through Dimensions Height 10.405 in (26.43 cm) Width 1.535 in (3.899 cm) Depth 27.697 in (70.35 cm) Capability IEEE 802.2, 802.3, 802.
QuickSpecs HP ProLiant BL25p Server Blade Technical Specifications Relative Humidity (non-condensing) Operating 20% to 80% Non-operating 5% to 95% Wet Bulb Temperature Operating 82.4° F (28° C) Non-operating 101.7° F (38.7° C) NOTE: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia.
QuickSpecs HP ProLiant BL25p Server Blade Technical Specifications Cable Support Safety Power Requirements Temperature Range Relative Humidity (non-condensing) Wet Bulb Temperature FCC Class A ICES-003 Class A AS/NZS 3548 Class A VCCI Class A UL/CUL Listed Accessory CE -48VDC: 1050 mA, 50 W maximum (per interconnect switch) Operating 50° to 95° F (10° to 35° C) Non-operating -22° to 140° F (-30° to 60° C) Operating 20% to 80% Non-operating 5% to 95% Operating 82.4° F (28° C) Non-operating 101.7° F (38.
QuickSpecs HP ProLiant BL25p Server Blade Technical Specifications Network Transfer Rate Connector EMI 10 Base-T (half-duplex) 10 Mbps 10 Base-T (full-duplex) 20 Mbps 100 Base-TX (half-duplex) 100 Mbps 100 Base-TX (full-duplex) 200 Mbps 1000 Base-TX (half and 2000 Mbps full-duplex) 1000 Base-SX (full-duplex) 2000 Mbps 12 RJ-45, 2 DB-9 (C-GbE2 Interconnect Kit) 8 LC fiber, 4 RJ-45, 2 DB-9 (F-GbE2 Interconnect Kit) FCC Class A ICES-003 Class A AS/NZS 3548 Class A VCCI Class A Safety UL/CUL Listed Accesso
QuickSpecs HP ProLiant BL25p Server Blade Technical Specifications Compliance Network Transfer Rate Connector EMI Safety Power Requirements Temperature Range DA - 12160 IEEE 802.1s, IEEE 802.1w, IEEE 802.1x, IEEE 802.3ad, IEEE 802.3x full duplex on 10BASE-T, 100BASE-TX, and, IEEE 802.1D Spanning-Tree Protocol, IEEE 802.1p CoS Prioritization, IEEE 802.1Q VLAN, IEEE 802.3 10BASE-T specification, IEEE 802.3u 100BASE-TX specification, IEEE 802.3ab 1000BASE-T specification, IEEE 802.
QuickSpecs HP ProLiant BL25p Server Blade Technical Specifications Relative Humidity (non-condensing) Operating 20% to 80% Non-operating 5% to 95% Wet Bulb Operating 82.4° F (28° C) Temperature Non-operating 101.7° F (38.7° C) NOTE: Operating temperature has an altitude derating of 34° F/1° C per 1,000 ft/304.8 m. No direct sunlight. Upper operating limit is 10,000 ft/3,048 m or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft/9,144 m or 30.3 KPa/4.4 psia.
QuickSpecs HP ProLiant BL25p Server Blade Technical Specifications Operating and Performance Specifications for Power Distribution Devices Power Enclosures or facility DC feeds Supported (3U each) Server blade enclosures supported (6U each) Total rack height of supported enclosures Dimensions Height Width Depth Weight Rated Operating Voltage Max Total Power Supported Total Max Input Current At Minimum Voltage Total Max Input Current At Nominal Voltage Power Bus Box 1 Mini Bus Bar 1 Scalable Bus Bar 2
QuickSpecs HP ProLiant BL25p Server Blade Technical Specifications Current In-rush current Input over-current Max steady state input 62.5A per server blade enclosure installed at current 48VDC Max steady state current per feed/total Power bus boxes 70 A/70A Mini bus bars 210 A/210A Scalable bus bars 210 A/350A or equivalent of 175A per feed* Must support up to 2X the maximum operating current per server blade enclosure (125 A) for up to 1.