HP ProDesk 400 G4 Small Form Factor (SFF) - Maintenance and Service Guide

Grounding the work area
To prevent static damage at the work area, observe the following precautions:
Cover the work surface with approved static-dissipative material. Provide a wrist strap connected to
the work surface and use properly grounded tools and equipment.
Use static-dissipative mats, foot straps, or air ionizers to give added protection.
Handle electrostatic-sensitive components, parts, and assemblies by the case or PCB laminate. Handle
them only at static-free work areas.
Turn o power and input signals before inserting and removing connectors or test equipment.
Use xtures made of static-safe materials when xtures must directly contact dissipative surfaces.
Keep work area free of nonconductive materials such as ordinary plastic assembly aids and Styrofoam.
Use eld service tools, such as cutters, screwdrivers, and vacuums, that are conductive.
Recommended materials and equipment
The following grounding equipment is recommended to prevent electrostatic damage:
Antistatic tape
Antistatic smocks, aprons, or sleeve protectors
Conductive bins and other assembly or soldering aids
Conductive foam
Conductive tabletop workstations with ground cords of one-megohm +/- 10% resistance
Static-dissipative table or oor mats with hard ties to ground
Field service kits
Static awareness labels
Wrist straps and footwear straps providing one-megohm +/- 10% resistance
Material handling packages
Conductive plastic bags
Conductive plastic tubes
Conductive tote boxes
Opaque shielding bags
Transparent metallized shielding bags
Transparent shielding tubes
16 Chapter 3 Routine care, SATA drive guidelines, and disassembly preparation