HP Z440, Z640, and Z840 Workstation Series - Maintenance and Service Guide

Ensuring proper ventilation
Proper ventilation for the system is important for workstation operation. Follow these guidelines:
Operate the workstation on a sturdy, level surface.
Provide at least 15.24 cm (6 inches) of clearance at the front and back of the workstation. (Workstation
models vary.)
Ensure that the ambient air temperature falls within the environmental specications listed in this
document.
NOTE: The ambient upper limit of 35°C (95°F) is only good up to 1524 m (5000 ft) elevation. There is a
1°C (33.8°F) per 304.8 m (1000 ft) derating above 1524 m (5000 ft). So, at 3,048 m (10,000 ft), the
upper ambient air temperature limit is 30°C (86°F).
For cabinet installation, ensure adequate cabinet ventilation and ensure that the ambient temperature
within the cabinet does not exceed specied limits.
Never restrict the incoming or outgoing airow of the workstation by blocking any vents or air intakes,
as shown in the following gure.
22 Chapter 1 Hardware overview