HP Z440, Z640, and Z840 Workstation Series - Maintenance and Service Guide

Memory
Supported DIMM congurations
NOTE: Mirroring and DIMM sparing are not supported.
Platform Conguration
HP Z440
Eight DIMM slots
Registered ECC DIMMS only
Maximum capacity: 128 GB
HP Z640
Four DIMM slots (single processor) or eight DIMM slots (dual processor)
Registered ECC DIMMS and ECC Load Reducing DIMMs
Maximum capacity:
RDIMMs: 64 GB for single processor and 128 GB for dual processor
LRDIMMs: 128 GB for single processor and 256 GB for dual processor.
The workstation can be congured for NUMA
HP Z840
16 DIMM slots (8 per processor)
ECC Registered DIMMs and ECC Load Reducing DIMMs
Maximum capacity:
RDIMMs: 128 GB for single processor and 256 GB for dual processor
LRDIMMs: 1024 GB for single processor and and 2048 GB for dual processor
The workstation can be congured for NUMA
BIOS errors and warnings
The BIOS generates warnings/errors on invalid memory congurations:
If the BIOS can nd a valid memory conguration by disabling plugged-in memory, it does so and
reports a warning during POST. the workstation can still be started. The warning will indicate the
location of the failed DIMM on the system board.
If there is no way for the BIOS to obtain a valid memory conguration by disabling plugged-in memory,
the BIOS halts with a diagnostics 2006 code for memory error (ve beeps and blinks).
DIMM installation guidelines
Install only HP-approved DDR4 DIMMs
CAUTION: HP ships only DIMMs that are electrically and thermally compatible with this workstation.
Because third-party DIMMs might not be electrically or thermally compatible, they are not supported by
HP.
Install only HP-approved DDR4 DIMMs. See http://www.hp.com/go/quickspecs to nd DIMMs that are
compatible with the workstation.
UDIMM (Unbuered), RDIMM (Registered) and LR DIMM (Load Reduction) memory cannot be mixed. All
memory installed in the system must be either UDIMM or RDIMM or LR DIMMs.Supported DIMM
congurations on page 65species which technologies are supported on each platform.
Component replacement guidelines 65