3. O bserve the EMU to ensure the error is corrected.
4. If resetting the EMU did not c orrect the problem, replace the EMU.
5. If unable to correct the problem, contact your HP authorized service representative.
0.7.01.03 UNRECOVERABLE Condition—Power supply shutdown
This message only appears on the Command View EVA GUI to report a power supply has already
shut down. This message can b e the result of the controller shutdown c om mand or an EMU or power
supply initi
ated power shutdown.
This message cannot be displayed until a fter restoration of power. Therefore, there is no corrective
action required.
0.7.01.04 INFORMATION condition—EMU internal data
The EMU is unable to collect data for the SCSI-3 Engineering Ser vices (SES) page. This condition report
remains active for 15 seconds. The condition report affects only internal EMU operations. There is no
degradation of enclosure op erations.
The EMU initiates automatic recovery procedures.
If the problem is not automatically corrected after one minute, contact your HP authorized service
representative.
0.7.01.05 U
NRECOVERABLE condition—Backplane NVRAM
NOTE:
IMPORTANT
Backplane NVR AM errors usually occur during manufacture. At this time they are identied and
corrected. They rarely occur d uring normal operation.
When a backplane NVRAM is not programmed or c annot be read by the EMU, there is no
communication with the disk drives. This condition repor t remains active until the problem is corrected.
Complete the following procedure to correct this problem:
1. Record all six characters of the condition report.
2. Reset the EMU.
3. O bserve the EMU to ensure the error is corrected.
4. If resetting the EMU did not correct the problem, contact your HP authorized service representative.
0.7.01.10 NONCRITICAL condition—NVRAM invalid read data
The da ta read from the EMU NVRAM is invalid. This error i nitiates an automatic recovery process. This
condition report remains active until the problem is corrected.
If the automatic recovery process does not correct the problem, complete the following procedure:
1. Record all six characters of the condition report.
2. Reset the EMU.
3. O bserve the EMU to ensure the error is corrected.
4. If resetting the enclosure did not correct the problem, contact your HP authorized service
representative.
Enterprise Virtual Array 3000/5000 user guide (VCS 3.110)