Instruction Manual

CXO7359B
˚
1
2
Figure 70 Installing and removing a drive blank
NOTE:
When installing drives, start at slot one, and do not leave blank slots between drives. If mixing online
and near-online drives, a minimum of 8 online and 8 near-online drives are required. When loading
drives into racks, align drives vertically by capacity.
Howtoremoveadriveblank
Complete the following procedure to remove a drive blank:
1. Grasp the drive blank by the two tabs (1 and 2, Figure 70).
2. Lift up on the bottom tab 1 and pull the blank out of the enclosure.
Protecting ber optic connections
This section provides protection and cleaning methods for ber optic connectors.
Contamination of the beropticconnectorsoneitheratransceiveroracableconnectorcanimpede
the transmission of data. Therefore, p rotecting the connector tips against contamination or damage
is imperative. The tips can be contaminated by touching them, by dust, or by debris. They can be
damaged when dropped. To protect the connectors against contamination or damage, use the dust
covers or dust caps provided by the manufacturer. These covers are removed during installation, and
are installed whenever the transceivers or cables are disconnected. Cleaning the connectors should
remove contamination.
The transceiver dust caps protect the transceivers from contamination.
CAUTION:
To avoid damage to the connectors, always install the dust covers or dust caps whenever a transceiver or
a ber cable is disconnected. Remove, but do not discard, the dust covers or dust caps from transceivers
or ber cable connectors on ly when they are connected.
To mini
mize the risk of contamination or damage, do the following:
Dust Covers—Remove and retain the dust covers and dust caps when installing an I/O module, a
transceiver or a cable. Install the dust covers when disconnecting a transceiver or cable.
Enterprise Virtual Array 3000/5000 user guide (VCS 3.110)
163