Instruction Manual
• Move the rack.
• Stabiliz e the rack.
• Inspectthestoragesystem.
• Install the controller cache batteries.
• Apply power.
• Attach the controllers to the fabric.
Entering data using the OCP
Two pieces of data critical to initial setup must be entered into the OCP:
• WWN —Mandatory to complete setup.
• Storage syst
em password—Optional. A passwor d is a security interlock that allows only specific
instances o
f Command View EVA to access the storage system.
Setting up a controller pair using the OCP
Fibre Channel protocol requires that each controller pair has a unique Nod e WWN. This 16-character
alphanumeric name identifies the controller pair on the storage system. The Enterprise Virtual Array
World Wide Name Label identifies the W WN for each storage system. The Node WWN labels, similar
to the one shown in Figure 11, identify the storage system WW N and checksum. During the installation of
the storage system, t wo W WN labels are attached to the rack on both sides of the controller enclosures.
CXO7545
A
Figure 11 Sample node WWN label
NOTE:
ThecontrollerpairWWNisuniquetoacontrollerpairandcannotbeusedforanyothercontrollerpair
or device an ywhere on the network. Figure 12 shows the location of the WWN label on a controller pair.
This is the only WWN applicable to any controller installed in a specificphysicallocation,evena
replacement controller.
Once a WWN is assigned to a controller, you cannot change the WWN while the controller is part
ofthesamestoragesystem.
Enterprise Virtual Array 3000/5000 user guide (VCS 3.110)