Instruction Manual

2 Configuration rules and guidelines
This chapter discusses the rules and guidelines for the HP StorageWorks EVA and EVA4400 iSCSI
connectivity option. This chapter contains the following topics:
Operating system rules and guidelines, page 32
EVA storage system rules and guidelines, page 37
Fibre Channel switch/fabric rules and guidelines, page 39
Command View EVA management rules and guidelines, page 39
IP network rules and guidelines, page 39
EVA and EVA4400 iSCSI Connectivity option
This section contains information about limits, rules, and guidelines for the EVA and EVA4400 iSCSI
Connectivity option, including:
EVA and EVA4400 iSCSI connectivity option architectural design limits
EVA and EVA4400 iSCSI connectivity option supported maximums
General EVA and EVA4400 iSCSI connectivity rules
Operating system rules and guidelines
EVA and EVA4400 iSCSI connectivity option architectural design limits
Maximum of 256 connections per iSCSI port
Maximum of 16 Fibre Channel targets (a target connected to both Fibre Channel (FC) ports is only
counted once)
NOTE:
The architectural design limits listed do not constitute supported configurations.
EVA and EVA4400 iSCSI connectivity option supported maximums
Table 5 shows the supported mpx100 maximums.
Table 5 Supported mpx100 maximums
Maximum per EVA or EVA4400 iSCSI connectivity solutionDescription
Hardware
1EVA storage system
2mpx100/100b
EVA iSCSI Connectivity User Guide 31