Instruction Manual

iSNS
Multipath
OpenVMS V8.3-1H1 or later
Not supported:
CHAP
Header and Data Digests
iSCSI boot
iSCSI Initiator software
The EVA iSCSI option supports the OpenVMS native iSCSI software Initiator. See OpenVMS software
requirements, page 36 for information on version support.
EVA storage system rules and guidelines
Table 7 identifies the EVA storage system rules and guidelines.
Table 7 EVA configuration table (mpx100/100b)
Direct con-
nect mpx100
Fabric attach
mpx100
Second
mpx100
1
One mpx100
Software ver-
sion
Operating
system
EVA storage
system
For the latest
information
on operating
system ver-
sion support,
see the
product re-
lease notes
or SPOCK at
http://
www.hp.com/
storage/
spock. You
must sign up
for an HP
Passport to
enable ac-
cess.
Microsoft
Windows
EVA4x00/
6x00/8x00
Not suppor-
ted
Apple Mac
OS X
Not suppor-
ted
HP Open-
VMS
Not suppor-
ted
Microsoft
Windows
EVA3000/
5000
Not suppor-
ted
Apple Mac
OS X
Not suppor-
ted
OpenVMS
Sun Solaris
EVA4x00/
6x00/8x00
VMware ESX
1
For configurations that include both single-path and multipath operating systems, single-path operating systems are supported
for single-path attachment on either (but not both) multipath mpx100s.
An EVA storage system configuration is considered to have two redundant HSV controllers. The
following list details the limitations of an EVA storage system by failover mode configuration:
In a fabric connect configuration, a maximum of two mpx100's/100b's can be zoned with one
EVA storage system.
In a fabric connect configuration, a maximum of one EVA storage system can be zoned with a
maximum of two mpx100's/100b's.
In a direct connect configuration, a maximum of two mpx100's/100b's are supported to one EVA
storage system.
EVA iSCSI Connectivity User Guide 37