Instruction Manual

d. Press the Right Arrow key. Fabric is displayed.
e. Press the Down Arrow key. Direct Connect is displayed.
f. Press the Right Arrow key. Port 1 is displayed.
g. Press the Down Arrow key until the port that you want to change to Direct Connect
Mode is displayed.
h. Press Enter.
i. Repeat the process for the other controller.
8. Continue with Connect the mpx100/100b to an IP switch on page 47.
Field fabric attachHP StorageWorks EVA or EVA4400 iSCSI connectivity
option with fabric attach mode
Figure 8 on page 28 illustrates the fabric iSCSIFibre Channel attachment mode configuration.
To install the iSCSI connectivity option with fabric attachment mode:
1. Rack mount the mpx100/100b. (See Rack mount the mpx100/100b on page 46.)
2. Install SFPs in the mpx100/100b ports ( FC1, FC2) and the top and bottom controller FP ports.
3. Connect one end of the orange Fibre Channel cable to the FC1 SFP port of the mpx100/100b.
Connect the other end of the orange Fibre Channel cable to any available SFP port on the Fibre
Channel switch.
4. Connect one end of the orange Fibre Channel cable to the FC2 SFP port of the mpx100/100b.
Connect the other end of the orange Fibre Channel cable to any available SFP port on the Fibre
Channel switch.
5. Connect one end of the orange Fibre Channel cable to any available SFP port on the Fibre
Channel switch. Connect the other end of the orange Fibre Channel cable to an available FP
port on the top HSV controller.
6. Connect one end of the orange Fibre Channel cable to any available SFP port on the Fibre
Channel switch. Connect the other end of the orange Fibre Channel cable to an available FP
port on the bottom HSV controller.
7. Continue with Connect the mpx100/100b to an IP switch on page 47.
Multipath direct connectHP StorageWorks EVA or EVA4400 iSCSI upgrade
option for multipathing capability and direct connect attachment mode
Figure 8 on page 28 illustrates the EVA iSCSI direct connect mode for multipathing option.
To install the upgrade option with direct connect attachment mode:
1. Insert the new mpx100/100b into the rack shelf next to the existing mpx100/100b.
2. Remove the black Fibre Channel cable from the existing mpx100 FC2 port and connect it to the
new mpx100 FC1 port.
3. Continue with Connect the mpx100/100b to an IP switch on page 47.
Multipath fabric attachHP StorageWorks EVA or EVA4400 iSCSI upgrade
option with multipathing capability and fabric attach mode
Figure 9 on page 29 illustrates the EVA iSCSI fabric attach mode for multipathing option.
To install the upgrade option with multipath direct connect attachment mode:
1. Insert the new mpx100/100b into the rack shelf next to the existing mpx100/100b.
EVA iSCSI Connectivity User Guide 45