Instruction Manual

Starting the mpx100/100b
To start the mpx100/100b:
1. Attach the AC power cord to the mpx100/100b and the power distribution unit (PDU). Verify
that the mpx100s/100b's System Power LED is illuminated.
The mpx100/100b runs a self-test and begins normal operation.
2. Verify that the Heartbeat LED is blinking (once per second) and that the Input Fault LED is not illu-
minated. Figure 11 shows the location of the ports and LEDs on the mpx100/100b.
Figure 11 The mpx100 port and LED locations
.
2. Heartbeat LED1. Management port (10/100 Ethernet)
4. System Fault LED3. Input Power LED
6. iSCSI ports5. FC ports
8. AC power7. RS232 port
Setting the mpx100/100b management port to use HP
StorageWorks Command View EVA
Communication between the mpx100/100b and HP Command View EVA is established through the
IP management port of the mpx100/100b and the IP connection of the HP Command View EVA
application server. This link is necessary for iSCSI device discovery and subsequent iSCSI settings of
the mpx100/100b through HP Command View EVA.
To set the mpx100/100b management port:
1. Use Telnet to connect to the mpx100/100b management port, or connect to the mpx100/100b
serial port using the HP-supplied connector.
NOTE:
The mpx100/100b management ports default IP address is 10.0.0.1/255.0.0.0. The
mpx100/100b serial port's default setting is 115200/8/n/1.
2. Log in with the user name guest and the password password.
Installing and upgrading EVA iSCSI connectivity48