Instruction Manual

Figure 16 Chassis controls
.
Maintenance button
The Maintenance button is a multifunction momentary switch on the front panel. It provides the following
functions:
Reset
Select boot image
Reset IP address
Enable DHCP
Factory defaults
Resetting the mpx100/100b
To reset the mpx100/100b, use a pointed nonmetallic tool to briefly press and release (less than two
seconds) the Maintenance button. The mpx100/100b responds as follows:
1. All the chassis LEDs are illuminated.
2. After approximately two seconds, the power-on self-test (POST) begins, extinguishing the Heartbeat
and System Fault LEDs.
3. When the POST is complete, the Power LED illuminates and the Heartbeat LED flashes once per
second.
Resetting the IP address
To reset the mpx100/100b and restore the maintenance port IP address to the default of 10.0.0.1,
briefly press the Maintenance button with a pointed non-metallic tool, releasing the button after six
seconds (six flashes of the Heartbeat LED). The mpx100/100b boots and sets the maintenance port
to IP address 10.0.0.1. The boot time is less than one minute.
NOTE:
Setting the IP address by this method is not persistent; to make the change persistent, use the command
line interface (CLI) or GUI.
Enabling DHCP
Reset the mpx100/100b and configure the maintenance port to use DHCP to access its IP address.
However, enabling DHCP by this method is not persistent. To make the change persistent, use the CLI
or GUI.
EVA iSCSI Connectivity User Guide 53