User Manual

EMU Generated Condition Reports
163Enterprise Virtual Array 3000 User Guide
Correcting Errors
Correcting an error may require you to perform a specific set of actions. In some
cases, the only available corrective action is to replace the element.
Table 43 lists the element type codes assigned to the drive enclosure elements.
Elements that do not have an active condition report are shaded.
Drive Conditions
The format of a disk drive condition report is 0.1.en.ec, where:
0.1. is the disk drive element type number
en. is the two-character disk drive element
Table 43: Assigned Element Type Codes
Code Element
0.1. Disk Drives (see ““Drive Conditions” on page 163)
0.2. Power Supplies (see Figure 65 on page 167)
0.3. Blowers (see Figure 66 on page 169)
0.4. Temperature Sensors (see Table 44 on page 172)
0.6. Audible Alarm
1
1. A shaded element does not generate a condition report. However, for any
error, you should record the error code. Then, implement the recommended
corrective action.
0.7. EMU
0.C. Controller OCP LCD
1
0.F. Transceivers (see Figure 68 on page 181)
1.0. Language
1
1.1. Communication Port
1
1.2. Voltage Sensors (see Table 45 on page 182)
1.3. Current Sensors (see Table 45 on page 182)
8.0. Drive Enclosure
1
8.2. Drive Enclosure Backplane
8.7. I/O Modules (see Figure 69 on page 185)
F.F. Host