User Manual

EMU Generated Condition Reports
185Enterprise Virtual Array 3000 User Guide
8.2.01.12 NONCRITICAL ConditionBackplane NVRAM Read Failure
The system is unable to read data from the NVRAM. This problem prevents
communication between elements in the enclosure. This condition report is active
for 15 seconds.
To correct this problem, record all six characters of the condition report, then
contact your HP authorized service representative.
8.2.01.13 NONCRITICAL ConditionBackplane WWN Is Blank
The system is unable to read valid data from the NVRAM. This report is active
until corrected. This condition can result in incorrect device location data being
displayed.
To correct this problem, record all six characters of the condition report, then
contact your HP authorized service representative.
I/O Module Conditions
The format of an I/O module condition report is 8.7.en.ec, where:
8.7. is the I/O module element type number
en. is the two-character I/O module element number. See Figure 69.
ec is the error code
Correction of an I/O module problem normally requires replacing the module.
The following sections define the I/O module problem by I/O module location.
1 I/O Module A (01)
2 I/O Module B (02)
Figure 69: I/O module element numbering
CXO7951A
12