Command Reference Guide

3Com Router 3000 Ethernet Family
Command Reference Guide Chapter 3 HWPing Commands
3Com Corporation
3-19
Note:
After you execute the test-enable command, the system does not display the test
result. You may view the test result information by executing the display hwping
command.
Related command: display hwping.
Example
# Execute the HWPing test defined by the test group wgw-testicmp.
[Router-hwping-wgw-testicmp] test-enable
3.1.27 test-failtimes
Syntax
test-failtimes times
undo test-failtimes
View
HWPing test group view
Parameter
times: Number of consecutive test failures. It is in the range 1 to 15 and defaults to 1.
Description
Use the test-failtimes command to configure the number of consecutive test failures
allowed before a trap is sent to the NMS.
Use the undo test-failtimes command to restore the default.
Note:
A test may include multiple probes.
Example
# Send a trap to the NMS after three consecutive test failures.
[Router] test-failtimes 3