Command Reference Guide

3Com Router 3000 Ethernet Family
Command Reference Guide Chapter 1 Interface Management Commands
3Com Corporation
1-8
[router-Ethernet0/0/0] undo enable snmp trap updown
1.1.7 flow-interval
Syntax
flow-interval seconds
undo flow-interval
View
System view
Parameter
seconds: Statistic interval in the range 1 to 1500 seconds. It defaults to 300 seconds.
Description
Use the flow-interval command to configure the interval for measuring the average
rate of the interfaces.
Use the undo flow-interval command to restore the default.
Related command: display interface.
Example
# Set the interval for measuring the average interface rate to 10 seconds.
[3Com ] flow-interval 10
# Display information on Ethernet0/0/0.
[3Com ] display interface Ethernet 0/0/0
Ethernet0/0/0 current state :UP
Line protocol current state :UP
Description : Ethernet0/0/0 Interface
The Maximum Transmit Unit is 1500, Hold timer is 10(sec)
Internet Address is 202.82.28.28/28
Internet Address is 10.0.103.254/24 Sub
Internet Address is 10.0.102.254/24 Sub
IP Sending Frames' Format is PKTFMT_ETHNT_2, Hardware address is
00e0-fc12-384f
Media type is twisted pair, loopback not set, promiscuous mode not set
100Mb/s, Full-duplex, link type is force link
Output flow-control is disabled, input flow-control is disabled
Output queue : (Urgent queue : Size/Length/Discards) 0/50/0
Output queue : (Protocol queue : Size/Length/Discards) 0/500/0
Output queue : (FIFO queuing : Size/Length/Discards) 0/75/0
Last 30 seconds input rate 138.36 bytes/sec, 1.63 packets/sec