Command Reference Guide
3Com Router 3000 Ethernet Family
Command Reference Guide
Chapter 4 Integrated IS-IS Configuration Commands
3Com Corporation
4-36
Description
Use the timer lsp-max-age command to configure the maximum lifetime of an LSP
generated by the current router.
Use the undo timer lsp-max-age command to restore the default value.
When a router generates the LSP of the system, it will fill in the maximum lifetime of this
LSP. When other routers receive this LSP, its lifetime will be reduced continuously as
the time goes by. If updated LSP has not been received before the old one times out,
this LSP will be deleted from the LSDB.
Related command: timer lsp-refresh.
Example
# Set the lifetime of an LSP generated by the current system to 25 minutes, i.e., 1500
seconds.
[3Com -isis] timer lsp-max-age 1500
4.1.44 timer lsp-refresh
Syntax
timer lsp-refresh seconds
undo timer lsp-refresh
View
IS-IS view
Parameter
seconds: Specifies the LSP refresh interval, measured in seconds. The range is 1 to
65535. The default value is 900 seconds.
Description
Use the timer lsp-refresh command to configure the refresh interval of LSP.
Use the undo timer lsp-refresh command to restore the default value.
By this mechanism, synchronization of the LSPs within the entire area can be
maintained.
Related command: timer lsp-max-age.
Example
# Set the LSP refresh interval of the current system to 1500 seconds.
[3Com -isis] timer lsp-refresh 1500