Command Reference Guide

3Com Router 3000 Ethernet Family
Command Reference Guide Chapter 2 Auto Detect Configuration Commands
3Com Corporation
2-3
ping wait time(s): 2
detect retry times: 2
detect ip option: and
group state: not detecting
register module num: 0
detect ip number: 1
detect-list ip address next-hop
1 1.1.1.1 1.1.1.5
Table 2-1 Description on the fields of the display detect-group command
Field Description
detect-group 1
The following configuration information
is about detect group 1
detect loop time(s): 15 The auto detect interval is 15 seconds
ping wait time(s): 2
The timeout period of a probing attempt
is 2 seconds
detect retry times: 2 The number of probing retries is 2
detect ip option: and
The logical relationship between the
addresses in the detect group is and
group state: not detecting
Current state of the detect group is that
no probing is going on
register module num: 0
Count of times the detect group has
been referenced
detect ip number: 1
Number of IP addresses in the detect
group
detect-list
Sequence number of an IP address in
the detect group
ip address IP address to be probed
next-hop
Next hop IP address for reaching the IP
address to be probed
2.1.4 option
Syntax
option [ and | or ]
undo option [ and | or ]
View