Command Reference Guide

3Com Router 3000 Ethernet Family
Command Reference Guide Chapter 3 HWPing Commands
3Com Corporation
3-1
Chapter 3 HWPing Commands
3.1 HWPing Client Commands
3.1.1 count
Syntax
count times
undo count
View
HWPing test group view
Parameter
times: Number of the test packets to be transmitted. It is in the range 1 to 15 and
defaults to 1.
Description
Use the count command to configure the number of packets to be sent for each test.
Use the undo count command to restore the default.
A test timer starts when the system sends the first test packet. In the event that the
times argument is set greater than one, the system continues to send the second one
upon receipt of the reply to the first one. If receiving no reply upon expiry of the timer,
the system sends the second and all the remaining packets likewise.
Related command: frequency.
Example
# Send ten packets for each test.
[Router-administrator-icmp] count 10
3.1.2 datafill
Syntax
datafill string
undo datafill
View
HWPing test group view