Software Manual

B.15
controlport
InForm OS Version 2.3.1 Remote Copy User’s Guide
slot
Specifies the PCI bus slot in the specified node using a number from 0 to 6.
port
Specifies the Fibre Channel adaptor port number of the PCI card in the specified PCI
bus slot using
1 to 4.
<IP_address>
Specifies the IP address for a Remote Copy interface.
<gateway_address>
Specifies the gateway address for a Remote Copy interface.
<netmask>
Specifies the netmask for a Remote Copy interface.
<MTU_size>
Specifies the MTU size for a Remote Copy interface using an integer from 100 through
9000. If no integer is specified, the value defaults to 1500.
<speed> half|full
Use only with the rcip speed subcommand. Specifies the speed setting (10, 100, or 1000)
and duplex setting (half or full) for a Remote Copy interface. In addition to this specifier,
you must also specify an interface using <node:slot:port>. If no speed or duplex settings are
specified, or if you specify auto with the
rcip speed subcommand, the system auto-
negotiates the speed and duplex.
<connmode>
Specifies whether the port is used for a disk, host, or RCFC connection. This specifier must
be used when issuing the
config command.
RESTRICTIONS
See the InForm OS Command Line Interface Reference for a complete list of restrictions.
The controlport rcip addr command is only allowed for node/slot/port combinations
where there is an interface installed.