Operating System Software Owner manual

RESTRICTIONS
See the HP 3PAR InForm OS CLI Reference for a complete list of restrictions.
The controlport rcip addr command is only allowed for node/slot/port combinations
where there is an interface installed.
EXAMPLES
The following example shows how to increase MTU to 9000 on Gigabit Ethernet port 1 in node
6, slot 3:
# controlport rcip mtu 9000 6:3:1
Remote Copy change successful.
The following example shows how to set Remote Copy interface 172.16.1.11 on a GigE port
1 in node 6, slot 3 using a netmask of 255.255.255.0:
# controlport rcip addr 172.16.1.11 255.255.255.0 6:3:1
Are you sure you want to change the address for 6:3:1?
select q=quit y=yes n=no: y
Remote Copy interface change successful.
The following example shows how to set the gateway for Gigabit Ethernet port 1 in node 6, slot
3 using a gateway address of 172.16.1.1:
# controlport rcip gw 172.16.1.1 6:3:1
Are you sure you want to change the gateway for 6:3:1?
select q=quit y=yes n=no: y
Remote Copy interface change successful.
NOTES
The -f option forces the operation. Without the option, the command will prompt for
confirmation. In some cases the command will ask for confirmation even if the -f option is
specified because the operation might disrupt system operation.
The -m <mode> option for the rst subcommand cannot be specified if there are active
connections already using the port (port online) except as noted in the following section under
port pair protection. Port pair protection:
For dual-port LSI Fibre Channel adapters, both ports in the pair must use the same mode
(initiator or target).
For quad-port LSI Fibre Channel adapters, each port pair (ports 1 and 2, ports 3 and 4)
must use the same mode.
Changing the mode of one port in a pair (for example, from initiator to target) causes
the other port in the pair to undergo a mode change as well.
If there are active hosts or physical disks when issuing the controlport rst or offline
commands, a warning is returned and you are prompted for confirmation to complete the
execution of the commands.
When issuing the controlport ct, cl2, rate, or rscn commands, if there are active
disks on the port, an error is returned. If there are active hosts on the port, the -f option is
overridden (if specified), a warning is returned, and you are prompted for confirmation to
complete the execution of the commands.
The controlport rcip addr command is only allowed for node/slot/port combinations
where there is an interface installed.
controlport config mode changes are not allowed when ports are online.
236 The Remote Copy Commands