Operating System Software Owner manual

Local Setup
(not connected to the FC
SAN)
SystemASystemBTarget system
RCFC links
Node WWN:
2FF70002AC0000C3
Node WWN:
2FF70002AC000060
Node 0 WWN:
20110002AC000060
Node 0 WWN:
20210002AC0000C3
Node 1 WWN:
21210002AC0000C3
Node 1 WWN:
21320002AC000060
SynchronousMode
Backup system 2 (SystemC) is located far from the primary system and backup system 1, and
therefore must use an IP network.
An IP network connects all systems. (The two backup systems use the IP network to share a
standby link for failover and recovery purposes.)
Replication between SystemA and SystemC is in asynchronous periodic mode.
Local + Remote Setup
Example backup system 2Example backup system 1Example primary system
SystemCSystemBSystemASystem name
SystemASystemASystemBTarget system 1
RCIP links for target system
1
Node 2 IP address
10.100.33.96
Node 2 IP address
10.100.33.96
Node 2 IP address:
10.100.33.195
Node 3 IP address:
10.101.33.195
Node 3 IP address
10.101.33.96
Node 3 IP address
10.101.33.96
SystemBSystemCSystemCTarget system 2
RCIP links for target system
2
Node 2 IP address:
10.100.33.195
Node 2 IP address:
10.100.33.63
Node 2 IP address:
10.100.33.63
Node 3 IP address:
10.101.33.63
Node 3 IP address:
10.101.33.195
Node 3 IP address:
10.101.33.63
Asynchronous periodic —>
SystemA
Asynchronous periodic —>
SystemC
Mode
Verifying Connectivity between Systems
Verify the connectivity for each Remote Copy pair you are configuring.
RCIP Remote Copy pairs:
# controlport rcip ping <IP_address> <N:S:P>
RCFC Remote Copy pairs:
# showrctransport -rcfc
For more information, see “Verifying the Servers Are Connected” (page 35).
58 Setting Up Synchronous Long Distance Remote Copy