Reference Guide

2.9
3PAR InServ E-Class/F-Class Storage Server Physical Planning Manual
RAID 5 data to
parity ratios
2:1, 8:1 2:1, 8:1 2:1, 8:1
RAID 6 data to
parity ratios
6:2, 14:2 6:2, 14:2 6:2, 14:2
Drive capacities
(GB’s approx.)
146 15K FC, 300
15K FC, 400 FC, 450
15K FC, 1TB NL
50 SSD, 146 15K
FC, 300 15K FC,
400 FC, 450 15K
FC, 600 FC, 1TB
NL
50 SSD, 146 15K
FC, 300 15K FC,
400 FC, 450 15K
FC, 600 FC, 1TB
NL
Number of drive
chassis
2-8 2-12 4-24
Energy
consumption
efficiency
**
0.146 for a host-
maximized E200
configuration
using 750 GB
drives.
0.182 for either a
host or storage
maximized F200
using 300 15K GB
drives.
0.365 for a
storage
maximized F400
using 146 15K GB
drives.
* The F400 can also be configured with 2 controller nodes, in which case, the cache, host ports, number of
drives and raw capacity would be like those described for the F200.
Levels, ratios, and capacities all mixable within the same storage server. 1 GB=1,000,000,000 bytes.
A single drive chassis holds up to 16 drives in 3U of space within an EIA-standard rack.
**Japan Green Law statement of compliance: The energy consumption efficiency value has been
calculated per requirements for Category-G Magnetic Disk Drive Units by dividing the power
consumption, measured according to the definition in the Law Concerning the Rational Use of Energy,
by the storage capacity defined in the Energy Conservation Law.
Table 2-2. System Capacity for E-Class/F-Class Storage Servers (continued)
Feature E200 F200 F400 (4 Node)
*