Table 33 Environmental specifications (continued)
10% to 90% non-condensingHumidity
5% to 90% non-condensingShipping Humidity
Up to 8,000 ft. (2,400 m)Altitude
Not to exceed 500,000 particles per cubic foot of air at a size of 0.5 micron or largerAir Quality
Power specifications
The input voltage is a function of the country-specific input voltage to Enterprise storage system
rack power distribution units (PDUs). Table 34 (page 113) defines the AC input power available to
the drive enclosure power supplies.
CAUTION: The AC power distribution within a rack ensures balance to each PDA and reduces
the possibility of an overload condition. Changing the cabling to or from a PDM could cause an
overload condition.
Table 34 Enterprise storage system AC input line voltages
MaximumNominalMinimalSpecification
60 Hz service
63 Hz60 Hz57 HzAC Line Voltage
220 VAC202 VAC180 VACAC Line Voltage—Japan
220 VAC208 VAC180 VACAC Line Voltage–North America
254 VAC240 VAC208 VACAC Line Voltage–Europe
50 Hz service
53 Hz50 Hz47 HzAC Line Frequency
220 VAC202 VAC180 VACAC Line Voltage–Japan
235 VAC220 VAC190 VACAC Line Voltage–North America
244 VAC230 VAC200 VACAC Line Voltage–North America
254 VAC240 VAC208 VACAC Line Voltage–Europe
Table 35 Power Data (North America/Europe/Japan) maximum configuration
North America – 3 wire NEMA No. L6-30P, 30 amp (208 to 240V 50–60Hz 30A)
Europe – 3 wire, 2 pole IEC 309, 30 amp, (220 to 240V 50Hz 32A)
AC plug type (quantity 2)
SingleNumber of phases
17A @ 200V-240V AC, 60Hz total, 4.25 A per power cordRated current
North America – 208 or 230V
Europe – 230V
Nominal Line Voltage
Japan – 206V
187 to 256VRange Line Voltage
North America 60Hz, Europe 50Hz, Japan 50 or 60 HzLine Frequency
Storage system specifications 113