Datasheet

HP 400W Power Supply Factory Integrated Kit
HP 400W Power Supply Factory Integrated KitHP 400W Power Supply Factory Integrated Kit
HP 400W Power Supply Factory Integrated Kit
515739-B21
Input Voltage Range (Vrms)
100 to 240
Frequency Range (Nominal) (Hz)
50/60
Nominal Input Voltage (Vrms)
100
100100
100 120
120120
120 200
200200
200 208
208208
208 220
220220
220 230
230230
230 240
240240
240
Maximum Rated Output Wattage
400 400 400 400 400 400 400
Nominal Input Current (A rms)
5.5 5.0 2.5 2.4 2.3 2.2 2.1
Max Rated Input Wattage Rating (Watts)
510 500 480 480 480 480 480
Max. Rated VA (Volt-Amp)
520 520 500 500 500 500 500
Efficiency (%) at Max. Rated Output Wattage
83.0 84.0 86.0 86.0 87.0 87.0 87.0
Power Factor
0.97
Leakage Current (mA)
0.75 0.75 0.85 0.90 0.95 0.95 1.00
Max. Inrush Current (A peak)
35
Max. Inrush Current duration (mS)
20
Maximum British Thermal Unit Rating (BTU-Hr)
1739 1705 1636 1636 1636 1636 1636
HP 500W Power Supply Kit
HP 500W Power Supply KitHP 500W Power Supply Kit
HP 500W Power Supply Kit
583437-B21
Input Voltage Range (Vrms)
100 to 240
Frequency Range (Nominal) (Hz)
47/63
Nominal Input Voltage (Vrms)
100
100100
100 120
120120
120 200
200200
200 220
220220
220 230
230230
230 240
240240
240
Maximum Rated Output Wattage
500 500 500 500 500 500
Nominal Input Current (A rms)
5.74 4.99 2.86 2.58 2.46 2.36
Max Rated Input Wattage Rating (Watts)
568 568 562 556 556 556
Max. Rated VA (Volt-Amp)
574 574 573 567 567 567
Efficiency (%) at Max. Rated Output Wattage
88 88 89 90 90 90
Power Factor
0.99 0.99 0.98 0.98 0.98 0.98
Leakage Current (mA)
0.42 0.50 0.81 0.91 0.95 1.00
Maximum Inrush Current (A peak)
30 30 30 30 30 30
Maximum Inrush Current duration (mS)
20 20 20 20 20 20
Maximum British Thermal Unit Rating (BTU-Hr)
QuickSpecs
HP ProLiant DL120 Generation 6 (G6)
HP ProLiant DL120 Generation 6 (G6)HP ProLiant DL120 Generation 6 (G6)
HP ProLiant DL120 Generation 6 (G6)
Power Specifications
DA - 13504 Worldwide — Version 18 — November 14, 2011
Page 34