HP StorageWorks Modular Smart Array 50 Storage Enclosure User Guide May 2005 (Second Edition) Part Number 379396-002
© Copyright 2005 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. Microsoft, Windows, and Windows NT are U.S.
Contents Component identification 7 Front panel LEDs and buttons.............................................................................................................. 7 Rear panel components ........................................................................................................................ 8 Rear panel LEDs and buttons............................................................................................................... 9 SAS and SATA drive numbers .................
HP StorageWorks Modular Smart Array 50 Storage Enclosure User Guide Configuration and utilities 31 Configuration tools ............................................................................................................................ 31 Array Configuration Utility .................................................................................................... 31 Option ROM Configuration for Arrays ..................................................................................
Contents Electrostatic discharge 5 51 Preventing electrostatic discharge...................................................................................................... 51 Grounding methods to prevent electrostatic discharge ...................................................................... 52 Specifications 53 Environmental specifications ............................................................................................................. 53 Storage enclosure specifications .......
Component identification In this section Front panel LEDs and buttons ........................................................................................................7 Rear panel components...................................................................................................................8 Rear panel LEDs and buttons .........................................................................................................9 SAS and SATA drive numbers..................................
HP StorageWorks Modular Smart Array 50 Storage Enclosure User Guide Item Description Status 2 Fault LED Off = No fault condition Amber = Fault condition 3 Heartbeat LED Green = System activity Off = No system activity 4 Power On/Standby button/LED Green = On Amber = Standby (auxiliary power present) Off = Off Rear panel components Item Description 1 SAS In connector 2 SAS Out connector 3 Power supply 1 4 Power supply 2 5 System fan
Component identification Rear panel LEDs and buttons Item Description Status 1 I/O module fault LED Green = No fault condition Power supply 1 LED Green = Power available 2 Amber = Fault condition Amber = Fault condition Off = Power supply unseated from connector or failed 3 Power supply 2 LED Green = Power available Amber = Fault condition Off = Power supply unseated from connector or failed 4 System fan LED Green = Normal operation Amber = Fault condition Off = Fan unseated from connector
HP StorageWorks Modular Smart Array 50 Storage Enclosure User Guide Item Description Status 6 Fault LED Off = No fault condition Amber = Fault condition 7 Heartbeat LED Green = System activity Off = No system activity SAS and SATA drive numbers
Component identification SAS and SATA hard drive LEDs Item Description 1 Fault/ID LED (amber/blue) 2 Online LED (green) SAS and SATA hard drive LED combinations NOTE: Predictive failure alerts can occur only when the storage enclosure is connected to a Smart Array controller.
HP StorageWorks Modular Smart Array 50 Storage Enclosure User Guide Online/Activity LED (green) Fault/UID LED (amber/blue) Interpretation Flashing regularly (1 Hz) Amber, flashing regularly (1 Hz) Do not remove the drive. Removing a drive may terminate the current operation and cause data loss. The drive is part of an array that is undergoing capacity expansion or stripe migration, but a predictive failure alert has been received for this drive.
Operations In this section Power up the storage enclosure ....................................................................................................13 Power down the storage enclosure ...............................................................................................14 Important Safety Information Before installing this product, read the Important Safety Information document provided.
HP StorageWorks Modular Smart Array 50 Storage Enclosure User Guide Power down the storage enclosure CAUTION: In systems that use external data storage, be sure that the server is the first unit to be powered down and the last to be powered back up. Taking this precaution ensures that the system does not erroneously mark the drives as failed when the server is powered up. IMPORTANT: If installing a hot-plug device, it is not necessary to power down the storage enclosure. 1.
Setup In this section Rack planning resources...............................................................................................................15 Optimum environment..................................................................................................................16 Rack warnings ..............................................................................................................................19 Shipping contents ....................................................
HP StorageWorks Modular Smart Array 50 Storage Enclosure User Guide – Coupling multiple racks • The Rack Products Documentation CD enables you to view, search, and print documentation for HP and Compaq branded racks and rack options. It also helps you set up and optimize a rack in a manner that best fits your environment. If you intend to deploy and configure multiple servers in a single rack, refer to the white paper on high-density deployment on the HP website (http://www.hp.
Setup 17 CAUTION: Always use blanking panels to fill empty vertical spaces in the rack. This arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling that can lead to thermal damage. The 9000 and 10000 Series racks provide proper server cooling from flowthrough perforations in the front and rear doors that provide 64 percent open area for ventilation.
HP StorageWorks Modular Smart Array 50 Storage Enclosure User Guide Power requirements Installation of this equipment must comply with local and regional electrical regulations governing the installation of IT equipment by licensed electricians. This equipment is designed to operate in installations covered by NFPA 70, 1999 Edition (National Electric Code) and NFPA-75, 1992 (code for Protection of Electronic Computer/Data Processing Equipment).
Setup 19 Electrical grounding requirements The storage enclosure must be grounded properly for proper operation and safety. In the United States, you must install the equipment in accordance with NFPA 70, 1999 Edition (National Electric Code), Article 250, as well as any local and regional building codes. In Canada, you must install the equipment in accordance with Canadian Standards Association, CSA C22.1, Canadian Electrical Code.
HP StorageWorks Modular Smart Array 50 Storage Enclosure User Guide • At least two people are needed to safely unload the rack from the pallet. An empty 42U rack can weigh as much as 115 kg (253 lb), can stand more than 2.1 m (7 ft) tall, and may become unstable when being moved on its casters. • Never stand in front of the rack when it is rolling down the ramp from the pallet. Always handle the rack from both sides.
Setup 21 Use the following information when connecting peripheral cables and power cords to the storage enclosure. Item Description 1 SAS In connector 2 SAS Out connector 3 Power supply 1 4 Power supply 2 Installing hardware options Install any hardware options before initializing the storage enclosure. For options installation information, refer to the option documentation. For storage enclosure-specific information, refer to "Hardware Options Installation (on page 27).
HP StorageWorks Modular Smart Array 50 Storage Enclosure User Guide NOTE: When installing servers, HP recommends installing all storage enclosures at the bottom of the rack. To optimize cabling access, avoid interleaving the storage enclosure and server products. Choosing a configuration Cable procedures vary, depending on the configuration. Choose one of the following configurations.
Setup 23 Cascading (1+1) configuration Item Description 1 MSA50 storage enclosure 1 2 MSA50 storage enclosure 2 3 SAS cable 4 SAS cable 5 Server Cabling the storage enclosure After installing the storage enclosure in a rack, connect the SAS cables and power cords to the rear panel. Supported cables A 2-m (6.56-ft) SAS cable ships standard with the storage enclosure. To acquire different lengths, contact the nearest authorized HP reseller ("HP contact information" on page 55).
HP StorageWorks Modular Smart Array 50 Storage Enclosure User Guide SAS cabling guidelines Observe the following guidelines: • Only use supported SAS cables with 3-GB connectors • Always be sure that the servers attached to the storage enclosure are powered down and power cords are disconnected before connecting SAS cables. Power cords The power cord should be approved for use in your country.
Setup Updating firmware To update storage enclosure firmware, refer to the HP website (http://www.hp.com/msa50). After installing hardware and powering up the storage enclosure for the first time, be sure to verify that the host controllers and drives have the latest firmware. For firmware and software updates, refer to the HP website (http://h18004.www1.hp.com/support/files/storage/us/index.html).
Hardware options installation In this section Hard drive options ........................................................................................................................27 Hard drive options The storage enclosure supports up to 10 SFF SAS drives. Always populate hard drive bays starting with the lowest drive number ("SAS and SATA drive numbers" on page 10).
HP StorageWorks Modular Smart Array 50 Storage Enclosure User Guide 2. Remove the hard drive blank. 3. Prepare the hard drive.
Hardware options installation 4. Install the hard drive. IMPORTANT: When the drive is inserted, the drive LEDs flash for 2 seconds to indicate that the drive is seated properly and receiving power. 5. Determine the status of the hard drive from the SAS and SATA hard drive LED combinations (on page 11).
Configuration and utilities In this section Configuration tools .......................................................................................................................31 Management tools ........................................................................................................................32 Diagnostic tools ............................................................................................................................33 Remote support and analysis tools ....
HP StorageWorks Modular Smart Array 50 Storage Enclosure User Guide For optimum performance, the minimum display settings are 800 × 600 resolution and 256 colors. Servers running Microsoft® operating systems require Internet Explorer 5.5 (with Service Pack 1) or later. For Linux servers, refer to the README.TXT file for additional browser and support information. For more information, refer to the HP Array Configuration Utility User Guide on the Documentation CD or the HP website (http://www.hp.com).
Configuration and utilities 33 HP Systems Insight Manager HP SIM is a web-based application that allows system administrators to accomplish normal administrative tasks from any remote location, using a web browser. HP SIM provides device management capabilities that consolidate and integrate management data from HP and third-party devices. IMPORTANT: You must install and use HP SIM to benefit from the Pre-Failure Warranty for processors, hard drives, and memory modules.
HP StorageWorks Modular Smart Array 50 Storage Enclosure User Guide You can view recorded events in the IML in several ways, including the following: • From within HP SIM ("HP Systems Insight Manager" on page 33) • From within Survey Utility • From within operating system-specific IML viewers – For NetWare: IML Viewer – For Windows®: IML Viewer – For Linux: IML Viewer Application • From within HP Insight Diagnostics For more information, refer to the Management CD in the HP ProLiant Essentials
Configuration and utilities 35 Keeping the system current List of tools: Change control and proactive notification....................................................................................35 Natural language search assistant .................................................................................................35 Care Pack......................................................................................................................................
Removal and replacement procedures In this section Safety considerations....................................................................................................................37 Hard drive blank ...........................................................................................................................37 Hot-plug SAS or SATA hard drive ..............................................................................................38 Hot-plug power supply .......................
HP StorageWorks Modular Smart Array 50 Storage Enclosure User Guide To replace the blank, slide the blank into the bay until it locks into place. Hot-plug SAS or SATA hard drive You can replace hard drives without powering down the system. However, before replacing a degraded drive: • Open HP SIM and inspect the Error Counter window for each physical drive in the same array to confirm that no other drives have any errors. (For details, refer to the HP SIM documentation on the Management CD.
Removal and replacement procedures 39 – In RAID 1+0 configurations, any drives that are not mirrored to other removed or failed drives can be simultaneously replaced offline without data loss. To remove the component: CAUTION: To prevent improper cooling and thermal damage, do not operate the storage enclosure unless all bays are populated with either a component or a blank. 1. Determine the status of the hard drive from the hot-plug hard drive LEDs. 2. Back up all data on the hard drive. 3.
HP StorageWorks Modular Smart Array 50 Storage Enclosure User Guide In fault-tolerant configurations, allow the replacement drive to be reconstructed automatically with data from the other drives. While reconstruction is in progress, the online LED flashes. Hot-plug power supply CAUTION: To prevent improper cooling and thermal damage, do not operate the storage enclosure unless all bays are populated with either a component or a blank. To remove the component: 1.
Removal and replacement procedures To remove the component: To replace the component, reverse the removal procedure.
Regulatory compliance notices In this section Regulatory compliance identification numbers ............................................................................43 Federal Communications Commission notice ..............................................................................44 Declaration of conformity for products marked with the FCC logo, United States only .............45 Cables .............................................................................................................
HP StorageWorks Modular Smart Array 50 Storage Enclosure User Guide Federal Communications Commission notice Part 15 of the Federal Communications Commission (FCC) Rules and Regulations has established Radio Frequency (RF) emission limits to provide an interference-free radio frequency spectrum. Many electronic devices, including computers, generate RF energy incidental to their intended function and are, therefore, covered by these rules.
Regulatory compliance notices 45 Class B equipment This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
HP StorageWorks Modular Smart Array 50 Storage Enclosure User Guide • Hewlett-Packard Company P. O. Box 692000, Mail Stop 510101 Houston, Texas 77269-2000 • 1-281-514-3333 To identify this product, refer to the part, series, or model number found on the product. Cables Connections to this device must be made with shielded cables with metallic RFI/EMI connector hoods in order to maintain compliance with FCC Rules and Regulations.
Regulatory compliance notices 47 This marking is valid for non-Telecom products and EU harmonized Telecom products (e.g. Bluetooth). This marking is valid for EU non-harmonized Telecom products. *Notified body number (used only if applicable—refer to the product label) Canadian notice (Avis Canadien) Class A equipment This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
HP StorageWorks Modular Smart Array 50 Storage Enclosure User Guide Japanese notice BSMI notice
Regulatory compliance notices Korean notice A&B Class A equipment Class B equipment Battery replacement notice WARNING: The computer contains an internal lithium manganese dioxide, a vanadium pentoxide, or an alkaline battery pack. A risk of fire and burns exists if the battery pack is not properly handled.
HP StorageWorks Modular Smart Array 50 Storage Enclosure User Guide • Do not attempt to recharge the battery. • Do not expose the battery to temperatures higher than 60°C (140°F). • Do not disassemble, crush, puncture, short external contacts, or dispose of in fire or water. Batteries, battery packs, and accumulators should not be disposed of together with the general household waste.
Electrostatic discharge In this section Preventing electrostatic discharge ................................................................................................51 Grounding methods to prevent electrostatic discharge.................................................................52 Preventing electrostatic discharge To prevent damaging the system, be aware of the precautions you need to follow when setting up the system or handling parts.
HP StorageWorks Modular Smart Array 50 Storage Enclosure User Guide Grounding methods to prevent electrostatic discharge Several methods are used for grounding. Use one or more of the following methods when handling or installing electrostatic-sensitive parts: • Use a wrist strap connected by a ground cord to a grounded workstation or computer chassis. Wrist straps are flexible straps with a minimum of 1 megohm ±10 percent resistance in the ground cords.
Specifications In this section Environmental specifications .......................................................................................................53 Storage enclosure specifications...................................................................................................
HP StorageWorks Modular Smart Array 50 Storage Enclosure User Guide Specification Value Width 42.62 cm (16.78 in) Weight (maximum) 16.78 kg (37 lb) Weight (no drives installed) 12.7 kg (27.
Technical support In this section Before you contact HP..................................................................................................................55 HP contact information.................................................................................................................
HP StorageWorks Modular Smart Array 50 Storage Enclosure User Guide – Call 1-800-HP-INVENT (1-800-474-6836). This service is available 24 hours a day, 7 days a week. For continuous quality improvement, calls may be recorded or monitored. – If you have purchased a Care Pack (service upgrade), call 1-800-6333600. For more information about Care Packs, refer to the HP website (http://www.hp.com). • Outside North America, call the nearest HP Technical Support Phone Center.
Acronyms and abbreviations ACU Array Configuration Utility ADG Advanced Data Guarding (also known as RAID 6) ADU Array Diagnostics Utility CSA Canadian Standards Association HBA host bus adapter IEC International Electrotechnical Commission IEEE Institute of Electrical and Electronics Engineers IML Integrated Management Log
HP StorageWorks Modular Smart Array 50 Storage Enclosure User Guide MSA Modular Smart Array MSA50 Modular Smart Array 50 NEC National Electrical Code NEMA National Electrical Manufacturers Association NFPA National Fire Protection Association ORCA Option ROM Configuration for Arrays OSEM Open Services Event Manager PSP ProLiant Support Pack RAID redundant array of inexpensive (or independent) disks RBSU ROM-Based Setup Utility
Acronyms and abbreviations SAS serial attached SCSI SATA serial ATA SCSI small computer system interface SFF small form-factor SIM Systems Insight Manager TMRA recommended ambient operating temperature UID unit identification 59
Index A AC power supply 8 ACU (Array Configuration Utility) 31 additional information 55 ADU (Array Diagnostic Utility) 34 airflow requirements 16 Array Configuration Utility (ACU) 31 array, configuring 27 authorized reseller 55 B basic configuration 22 battery 49 blanks 37 BSMI notice 48 buttons 7, 9 E electrical grounding requirements 19 electrostatic discharge 51 enclosure LEDs 7, 9 environmental requirements 16 environmental specifications 53 F fans 8 fault LED 7, 9 Federal Communications Commiss
HP StorageWorks Modular Smart Array 50 Storage Enclosure User Guide J Japanese notice 48 power requirements 18 power supplies 8 powering down 14 powering up 13 K kit contents 20 L LED, power button 7 LEDs 7, 9, 11 LEDs, troubleshooting 11 LEDs, unit identification 7, 9 M maintenance 35 Management Agents 33 management tools 32 mounting rails 20 N Natural Language Search Assistant 35 O Open Services Event Manager 34 optimum environment 16 Option ROM Configuration for Arrays (ORCA) 32 options instal
Index T Taiwan battery recycling notice 50 technical support 55 telephone numbers 55 temperature ranges (environmental) 53 temperature requirements 17 troubleshooting 11 U updating the firmware 25 utilities 31, 32, 33, 34 W warnings 19 website, HP 55 63