HP Engage Go 10 Integrated Scanner Programming Reference Guide
© Copyright 2021 HP Development Company, L.P. Microsoft and Windows are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty.
Table of Contents Preface .......................................................................................................................................................................................... 1 Introduction ...................................................................................................................................................................... 1 Chapter Description ...............................................................................................
Decode Session Timeout ............................................................................................................................................... 18 Image Stabilization Timeout (Sense Mode) .................................................................................................................... 19 Reread Timeout..............................................................................................................................................................
Query OEM Serial Number ..................................................................................................................................... 39 Query Data Formatter Version ................................................................................................................................ 39 Chapter 4 USB Interface ............................................................................................................................................................
Enable/Disable Postal Symbologies ....................................................................................................................... 68 1D Twin Code ......................................................................................................................................................... 69 Surround GS1 Application Identifiers (AI’s) with Parentheses ................................................................................. 70 Code 128 ..............................
Transmit Preamble Character ................................................................................................................................. 87 Convert UPC-E to UPC-A ....................................................................................................................................... 87 UPC-A ............................................................................................................................................................................
Transmit Start/Stop Character............................................................................................................................... 105 Enable/Disable Code 39 Full ASCII ...................................................................................................................... 105 Enable/Disable Code 32 (Italian Pharma Code) ................................................................................................... 106 Code 32 Prefix ..............................
Code 11 ........................................................................................................................................................................ 122 Restore Factory Defaults ...................................................................................................................................... 122 Enable/Disable Code 11........................................................................................................................................
AIM 128 ........................................................................................................................................................................ 141 Restore Factory Defaults ...................................................................................................................................... 141 Enable/Disable AIM 128 ........................................................................................................................................
Enable/Disable QR Code ...................................................................................................................................... 158 Set Length Range for QR Code ............................................................................................................................ 159 QR Twin Code ....................................................................................................................................................... 160 QR Inverse ............
Chinese Sensible Twin Code ................................................................................................................................ 179 Chinese Sensible Code Inverse ............................................................................................................................ 180 GM Code ......................................................................................................................................................................
Japan Post ................................................................................................................................................................... 192 Restore Factory Defaults ...................................................................................................................................... 192 Enable/Disable Japan Post ...................................................................................................................................
Introduction .................................................................................................................................................................. 221 Global Settings ............................................................................................................................................................. 222 Enable/Disable All Prefixes/Suffixes......................................................................................................................
Code ID Table .............................................................................................................................................................. 259 Symbology ID Number ................................................................................................................................................. 261 ASCII Table .........................................................................................................................................................
Preface Introduction This manual provides detailed instructions for setting up and using the HP Engage Go 10 Integrated Scanner (hereinafter referred to as “the scanner”). Chapter Description Chapter 1, Getting Started : Gives a general description of the HP Engage Go 10 Integrated Scanner. Chapter 2, HP Barcode : Introduces a useful tool you can use to set up the HP Engage Go 10 Scanner N-Series Integrated Scanner.
Explanation of Icons This icon indicates something relevant to this manual. This icon indicates this information requires extra attention from the reader. This icon indicates handy tips that can help you use or configure the scanner with ease. This icon indicates practical examples that can help you to acquaint yourself with operations.
Chapter 1 Getting Started Introduction The HP Engage Go 10 Integrated Scanners are armed with CMOS image capturer, a computerized image recognition system-on-chip, featuring fast scanning and accurate decoding on barcodes on virtually any medium - paper, magnetic card, mobile phones and LCD displays.
Chapter 2 HP Barcode Scanner N-Series Configuration Utility HP Barcode Scanner N-Series Configuration Utility is a Windows-based configuration tool, which allows users to gain access to decoded data and captured images and to configure scanners.
Enter Setup Chapter 3 System Settings Introduction There are three ways to configure the HP Engage Go 10 Integrated Scanner: Barcode programming, command programming and Configuration Utility programming. Barcode Programming The HP Engage Go 10 Integrated Scanner can be configured by scanning programming barcodes. All user programmable features/options are described along with their programming barcodes/commands in the following sections. This programming method is most straightforward.
Enter Setup Programming Barcode/ Programming Command/Function The figure above is an example that shows you the programming barcode and command for the Enter Setup function: 1. The No Case Conversion barcode. 2. The No Case Conversion command. 3. The description of feature/option. 4. ** indicates factory default settings.
Enter Setup Use of Programming Command Besides the barcode programming method, the scanner can also be configured by serial commands (HEX) sent from the host device. All commands must be entered in uppercase letters. Command Syntax Prefix StorageType Tag SubTag {Data} [,SubTag {Data}] [;Tag SubTag {Data}] […] Suffix Prefix: “~0000” (HEX: 7E 01 30 30 30 30), 6 characters. StorageType: “@” (HEX: 40) or “#” (HEX: 23), 1 character.
Enter Setup The value of the StoreType field in a query command can be either “@” (HEX: 40) or “#” (HEX: 23). A query command with the SubTag field omitted means to query all the settings concerning a tag. For example, to query all the current settings about Code 11, you should enter 7E 01 30 30 30 30 40 43 31 31 2A 3B 03 (i.e. ~0000@C11*;). Responses Different from command sequence, the prefix of a response consists of the six characters of “0000” (HEX: 02 01 30 30 30 30).
Enter Setup Use of Programming Barcodes Scanning the Enter Setup barcode can enable the scanner to enter the setup mode. Then you can scan a number of programming barcodes to configure your scanner. To exit the setup mode, scan the Exit Setup barcode or a nonprograming barcode, or reboot the scanner. ** Exit Setup Enter Setup Programming barcode data (i.e. the characters under programming barcode) can be transmitted to the host device.
Enter Setup Illumination Mode A couple of illumination options are provided to improve the lighting conditions during every image capture: Normal: Illumination LEDs on the scanner are turned on during image capture. Always On: Illumination LEDs on the scanner keep on after the scanner is powered on. Off: Illumination LEDs on the scanner are off all the time.
Enter Setup Aiming When scanning/capturing image, the scanner projects an aiming pattern which allows positioning the target barcode within its field of view and thus makes decoding easier. Normal: The scanner projects an aiming pattern only during barcode scanning/capture. Always On: Aiming pattern is constantly on after the scanner is powered on. Off: Aiming pattern is off all the time. ** Normal Off Always On Good Read LED The LED can be programmed to be On or Off to indicate good read.
Enter Setup Good Read LED Duration This parameter sets the amount of time that the Good Read LED to remain on following a good read. It is programmable in 1ms increments from 1ms to 2,500ms. ** Short (20ms) Medium (120ms) Long (220ms) Prolonged (320ms) Custom (1 - 2,500ms) Set the Good Read LED duration to 800ms: 1. Scan the Enter Setup barcode. 2. Scan the Custom barcode. 3. Scan the numeric barcodes “8”, “0” and “0” from the “Digit Barcodes” section in Appendix. 4.
Enter Setup Power On Beep The scanner can be programmed to beep when it is powered on. Scan the Off barcode if you do not want a power on beep. ** On Off Good Read Beep Scanning the Off barcode can turn off the beep that indicates successful decode; scanning the On barcode can turn it back on.
Enter Setup Good Read Beep Duration This parameter sets the length of the beep the scanner emits on a good read. It is programmable in 1ms increments from 20ms to 300ms. Short (40ms) ** Medium (80ms) Long (120ms) Custom (20 – 300ms) Set the Good Read Beep duration to 200ms: 1. Scan the Enter Setup barcode. 2. Scan the Custom barcode. 3. Scan the numeric barcodes “2”, “0” and “0” from the “Digit Barcodes” section in Appendix. 4. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.
Enter Setup Good Read Beep Frequency This parameter is programmable in 1Hz increments from 20Hz to 20,000Hz. Extra Low (800Hz) Low (1600Hz) ** Medium (2730Hz) High (4200Hz) Custom (20 - 20,000Hz) Set the Good Read Beep frequency to 2,000Hz: 1. Scan the Enter Setup barcode. 2. Scan the Custom barcode. 3. Scan the numeric barcodes “2”, “0”, “0” and “0” from the “Digit Barcodes” section in Appendix. 4. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix. 5.
Enter Setup Good Read Beep Volume There are 20 volume levels to choose from. The bigger the value, the louder the Good Read Beep. ** Loud Medium Low Custom Volume (Level 1-50) Set the Good Read Beep volume to Level 8: 1. Scan the Enter Setup barcode. 2. Scan the Custom Volume barcode. 3. Scan the numeric barcode “8” from the “Digit Barcodes” section in Appendix. 4. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix. 5. Scan the Exit Setup barcode.
Enter Setup Scan Mode Level Mode: A trigger pull activates a decode session. The decode session continues until a barcode is decoded or you release the trigger. Sense Mode: The scanner activates a decode session every time it detects a barcode presented to it. The decode session continues until a barcode is decoded or the decode session timeout expires. Reread Timeout can avoid undesired rereading of same barcode in a given period of time.
Enter Setup Decode Session Timeout This parameter sets the maximum time decode session continues during a scan attempt. It is programmable in 1ms increments from 1ms to 3,600,000ms. When it is set to 0, the timeout is infinite. The default setting is 3,000ms. Decode Session Timeout Set the decode session timeout to 1,500ms: 1. Scan the Enter Setup barcode. 2. Scan the Decode Session Timeout barcode. 3. Scan the numeric barcodes “1”, “5”, “0” and “0” from the “Digit Barcodes” section in Appendix. 4.
Enter Setup Image Stabilization Timeout (Sense Mode) This parameter defines the amount of time the scanner will spend adapting to ambient environment after it decodes a barcode and “looks” for another. It is programmable in 1ms increments from 0ms to 3,000ms. The default setting is 500ms. Image Stabilization Timeout Set the image stabilization timeout to 800ms: 1. Scan the Enter Setup barcode. 2. Scan the Image Stabilization Timeout barcode. 3.
Enter Setup Reread Timeout Reread Timeout can avoid undesired rereading of same barcode in a given period of time. This feature is only applicable to the Sense and Continuous modes. Enable Reread Timeout: Do not allow the scanner to reread same barcode before the reread timeout expires. Disable Reread Timeout: Allow the scanner to reread same barcode. Enable Reread Timeout ** Disable Reread Timeout The following parameter sets the time interval between two successive reads on same barcode.
Enter Setup You may wish to restart the reread timeout when the scanner encounters the same barcode that was decoded in the last scan session before the reread timeout expires. To enable this feature, scan the Reread Timeout Reset On barcode. This feature is only effective when Reread Timeout is enabled. Reread Timeout Reset On ** Reread Timeout Reset Off Image Decoding Timeout Image Decoding Timeout specifies the maximum time the scanner will spend decoding an image.
Enter Setup Good Read Delay Good Read Delay sets the minimum amount of time before the scanner can read another barcode. This parameter is programmable in 1ms increments from 1ms to 3,600,000ms. The default setting is 500ms. Scan the appropriate barcode below to enable or disable the delay.
Enter Setup Sensitivity (Sense Mode) Sensitivity specifies the degree of acuteness of the scanner’s response to changes in images captured. There are 20 levels to choose from. The smaller the value, the higher the sensitivity and the lower requirement in image change to trigger the scanner. You can select an appropriate degree of sensitivity that fits the application environment. This feature is only applicable to the Sense mode.
Enter Setup Illumination Brightness Control Level 1 Level 2 ** Level 3 Level 4 Level 5 ** Exit Setup 24
Enter Setup Trigger Commands When Enable Trigger Commands is selected, you can activate and deactivate the scanner in the Level mode with serial trigger commands. Sending the Start Scanning command (default: T , user-programmable) to the scanner in the Level mode activates a decode session. The decode session continues until a barcode is decoded or the decode session timeout expires or the scanner receives the Stop Scanning command (default: P , userprogrammable).
Enter Setup Modify Stop Scanning Command The Stop Scanning command can consist of 1-10 characters (HEX values from 0x01 to 0xFF). In this command, the character “?” (HEX: 0x3F) cannot be the first character. The default Stop Scanning command is P . Modify Stop Scanning Command Set the Stop Scanning command to “*P”: 1. Scan the Enter Setup barcode. 2. Scan the Modify Stop Scanning Command barcode. 3. Scan the numeric barcodes “2”, “A”, “5” and “0” from the “Digit Barcodes” section in Appendix.
Enter Setup Turn On Good Read LED You may turn on the external Good Read LED of the scanner for a certain period of time with a command sent from the host. When using this feature, you should first query the range of possible values for the setting. Note that the scanner cannot scan barcodes when it is executing this command.
Enter Setup Turn On Aimer You may turn on the aimer on the scanner for a certain period of time with a command sent from the host. When using this feature, you should first query the range of possible values for the setting. Note that the scanner cannot scan barcodes when it is executing this command.
Enter Setup Decode Area Whole Area Decoding: The scanner attempts to decode barcode(s) within its field of view, from the center to the periphery, and transmits the barcode that has been first decoded. Specific Area Decoding: The scanner attempts to read barcode(s) within a specified decoding area and transmits the barcode that has been first decoded. This option allows the scanner to narrow its field of view to make sure it reads only those barcodes intended by the user.
Enter Setup If Specific Area Decoding is enabled, the scanner only reads barcodes that intersect the predefined decoding area. The default decoding area is an area of 40% top, 60% bottom, 40% left and 60% right of the scanner’s field of view You can define the decoding area using the Top of Decoding Area, Bottom of Decoding Area, Left of Decoding Area and Right of Decoding Area barcodes as well as numeric barcode(s) that represent(s) a desired percentage (0-100).
Enter Setup Barcode 1 Barcode 2 Program the scanner to only read Barcode 1 in the figure above by setting the decoding area to 10% top, 45% bottom, 15% left and 30% right: 1. Scan the Enter Setup barcode. 2. Scan the Top of Decoding Area barcode. 3. Scan the numeric barcode “0” from the “Digit Barcodes” section in Appendix. 4. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix. 5. Scan the Bottom of Decoding Area barcode. 6.
Enter Setup Image Flipping ** Do Not Flip Flip Horizontally Flip Vertically Flip Horizontally & Vertically ** Exit Setup 32
Enter Setup Example of image not flipped Example of image flipped horizontally Example of image flipped vertically Example of image flipped horizontally & vertically Bad Read Message Scan the appropriate barcode below to select whether or not to send a bad read message (user-programmable) when a good read does not occur before trigger release, or the decode session timeout expires, or the scanner receives the Stop Scanning command (For more information, see the “Serial Trigger Command” section in this
Enter Setup Set Bad Read Message A bad read message can contain up to 7 characters (HEX values from 0x00 to 0xFF). To set a bad read message, scan the Set Bad Read Message barcode, the numeric barcodes representing the hexadecimal values of desired character(s) and the Save barcode. The default setting is “NG”. Set Bad Read Message Set the bad read message to “F” (HEX: 0x46): 1. Scan the Enter Setup barcode. 2. Scan the Set Bad Read Message barcode. 3.
Enter Setup Operating Modes Auto Sleep Auto Sleep allows the engine to automatically enter the sleep mode if no operation or communication is performed for a time period (user programmable). Sending trigger signal or serial commands (it is recommended to send 0x3f) can awake the engine when connected to the host device via serial port.; sending trigger signal when connected to the host device via USB port.
Enter Setup Default Settings Factory Defaults Scanning the following barcode can restore the scanner to the factory defaults. You may need to reset all parameters to the factory defaults when: scanner is not properly configured so that it fails to decode barcodes. you forget previous configuration and want to avoid its impact. Restore All Factory Defaults Custom Defaults Scanning the Restore All Custom Defaults barcode can reset all parameters to the custom defaults.
Enter Setup Query Product Information After scanning the barcode below, the product information (including product name, firmware version, decoder version, hardware version, serial number, OEM serial number and manufacturing date) will be sent to the host device.
Enter Setup Query Decoder Version Query Decoder Version Query Hardware Version Query Hardware Version Query Product Serial Number Query Product Serial Number ** Exit Setup 38
Enter Setup Query Manufacturing Date Query Manufacturing Date Query OEM Serial Number Query OEM Serial Number Query Data Formatter Version Query Data Formatter Version 39 ** Exit Setup
Enter Setup Chapter 4 USB Interface Introduction There are three options for USB connection: USB HID Keyboard: The scanner’s transmission is simulated as USB keyboard input with no need for command configuration or a driver. Barcode data could be entered by the virtual keyboard directly and it is also convenient for the host device to receive data.
Enter Setup USB HID Keyboard When the scanner is connected to the USB port on a host device, you can enable the USB HID Keyboard feature by scanning the barcode below. The scanner’s transmission will be simulated as USB keyboard input. The Host receives keystrokes onthe virtual keyboard. It works on a Plug and Play basis and no driver is required. ** USB HID Keyboard If the host device allows keyboard input, then no extra software is needed for HID Keyboard input.
Enter Setup USB Country Keyboard Types Keyboard layouts vary from country to country. The default setting is U.S. keyboard. ** U.S.
Enter Setup France Germany/ Austria Greece Hungary Israel (Hebrew) Italy Latin America/ South America Netherlands (Dutch) 43 ** Exit Setup
Enter Setup Norway Poland Portugal Romania Russia Slovakia Spain Sweden ** Exit Setup 44
Enter Setup Switzerland (German) Turkey_F Turkey_Q UK Japan 45 ** Exit Setup
Enter Setup Beep on Unknown Character Due to the differences in keyboard layouts, some characters contained in barcode data may be unavailable on the selected keyboard. As a result, the scanner fails to transmit the unknown characters. Scan the appropriate barcode below to enable or disable the emission of beep when an unknown character is detected.
Enter Setup Emulate ALT+Keypad When Emulate ALT+Keypad is turned on, ASCII characters (0x20 - 0xFF) are sent over the numeric keypad no matter which keyboard type is selected. 1. ALT Make 2. Enter the number corresponding to a desired character on the keypad. 3. ALT Break After Emulate ALT+Keypad ON is selected, you need to choose the code page with which the barcodes were created and to turn Unicode Encoding On or Off depending on the encoding used by the application software.
Enter Setup Code Page Code pages define the mapping of character codes to characters. If the data received does not display with the proper characters, it may be because the barcode being scanned was created using a code page that is different from the one the host program is expecting. If this is the case, select the code page with which the barcodes were created by scanning the appropriate barcode below.
Enter Setup Code Page 1256 (Arabic) Code Page 1257 (Baltic) Code Page 1258 (Vietnamese) Code Page 936 (Simplified Chinese, GB2312,GBK) Code Page 950 (Traditional Chinese, Big5) Code Page 874 (Thai) Code Page 932 (Japanese, Shift-JIS) 49 ** Exit Setup
Enter Setup Unicode Encoding Different host program may use different character encodings for handling incoming barcode data. For instance, Microsoft Office Word uses Unicode encoding and therefore you should turn Unicode Encoding on, whereas Microsoft Office Excel or Notepad uses Code Page encoding and therefore you should turn Unicode Encoding off. This feature is only effective when Emulate ALT+Keypad is turned on.
Enter Setup Function Key Mapping When Ctrl+ASCII Mode is selected, function characters (0x00 - 0x1F) are sent as ASCII sequences. ** Disable Ctrl+ASCII Mode Alt+Keypad Mode If Ctrl+ASCII Mode is selected and other parameters of USB HID Keyboard adopt factory defaults, barcode data “A(i.e. Horizontal Tab)F” (0x41/0x09/0x46) is sent as below: “A” - Keystroke “A”. - “Ctrl Make” + Keystroke “I” + “Ctrl Break” “F” - Keystroke “F” For some text editors, “Ctrl I” means italic convert.
Enter Setup ASCII Function Key Mapping Table ASCII Function ASCII Value (HEX) Function Key Mapping Disabled Ctrl+ASCII NUL 00 Null Ctrl+@ SOH 01 Keypad Enter Ctrl+A STX 02 Caps Lock Ctrl+B ETX 03 ALT Ctrl+C EOT 04 Null Ctrl+D ENQ 05 CTRL Ctrl+E ACK 06 Null Ctrl+F BEL 07 Enter Ctrl+G BS 08 Left Arrow Ctrl+H HT 09 Horizontal Tab Ctrl+I LF 0A Down Arrow Ctrl+J VT 0B Vertical Tab Ctrl+K FF 0C Delete Ctrl+L CR 0D Enter Ctrl+M SO 0E Insert Ctrl+N SI
Enter Setup ASCII Function Key Mapping Table (Continued) The last five characters (0x1B~0x1F) in the table above apply to US keyboard layout only. The following chart provides the equivalents of these five characters for other countries. Country 53 Ctrl+ASCII United States Ctrl+[ Ctrl+\ Ctrl+] Ctrl+6 Ctrl+- Belgium Ctrl+[ Ctrl+< Ctrl+] Ctrl+6 Ctrl+- Scandinavia Ctrl+8 Ctrl+< Ctrl+9 Ctrl+6 Ctrl+- France Ctrl+^ Ctrl+8 Ctrl+$ Ctrl+6 Ctrl+= Germany Ctrl+Ã Ctrl++ Ctrl+6 Ctrl+- I
Enter Setup Inter-Keystroke Delay This parameter specifies the delay between emulated keystrokes.
Enter Setup Caps Lock The Caps Lock On options can invert upper and lower case characters contained in barcode data. This inversion occurs regardless of the state of Caps Lock key on the host device’s keyboard. To disable this feature, scan the appropriate Caps Lock OFF barcode below based on your keyboard.
Enter Setup Convert Case Scan the appropriate barcode below to convert all bar code data to your desired case. ** No Case Conversion Convert All to Upper Case Convert All to Lower Case When the Convert All to Lower Case feature is enabled, barcode data “AbC” is transmitted as “abc”. If Emulate ALT+Keypad ON is selected, Convert All to Lower Case and Convert All to Upper Case do not function.
Enter Setup Emulate Numeric Keypad Do Not Emulate Numeric Keypad 1: Sending a number (0-9) is emulated as keystroke(s) on main keyboard. Emulate Numeric Keypad 1: Sending a number (0-9) is emulated as keystroke(s) on numeric keypad. The state of Num Lock on the simulated numeric keypad is determined by its equivalent on the host device. If Num Lock on the host device is turned off, the output of simulated numeric keypad is function key instead of number.
Enter Setup ** Do Not Emulate Numeric Keypad 2 Emulate Numeric Keypad 2 Emulate ALT+Keypad ON prevails over Emulate Numeric Keypad. Supposing the Emulate Numeric Keypad 1 feature is enabled: if Num Lock on the host device is ON, “A4.5” is transmitted as “A4.5”; if Num Lock on the host device is OFF, “A4.5” is transmitted as “.A”: 1. “A” is sent on main keyboard; 2. “4” is sent as the function key “Cursor Move to Left”; 3. “.” is sent on main keyboard; 4.
Enter Setup Fast Mode When Fast Mode On is selected, the scanner sends characters to the Host faster. If the Host drops characters, turn the Fast Mode off or change the polling rate to a bigger value.
Enter Setup Polling Rate This parameter specifies the polling rate for a USB keyboard. If the Host drops characters, change the polling rate to a bigger value.
Enter Setup 8ms 9ms 10ms 61 ** Exit Setup
Enter Setup USB CDC (COM) If your scanner is connected to the USB port on a host device, the USB CDC (COM) feature allows the host device to receive data in the way as a serial port does. A driver is needed when using this feature.
Enter Setup HID POS (POS HID Barcode Scanner) Introduction The HID-POS interface is recommended for new application programs. It can send up to 56 characters in a single USB report and appears more efficient than keyboard emulation. Features: HID based, no custom driver required. Way more efficient in communication than keyboard emulation.
Enter Setup Acquire Scanned Data After a barcode is decoded, the scanner sends an input report as below: Bit Byte 7 6 5 4 3 2 0 Report ID = 0x02 1 Barcode Length 2-57 Decoded Data (1-56) 58-61 Reserved 62 HP Symbology Identifier or N/C: 0x00 63 - - - - - - 1 0 - Decoded data continued Send Command to the Scanner This output report is used to send commands to the scanner. All programming commands can be used.
Enter Setup VID/PID USB uses VID (Vendor ID) and PID (Product ID) to identify and locate a device. The VID is assigned by USB Implementers Forum. HP’s vendor ID is 03F0 (Hex). A range of PIDs are used for each HP Inc product family. Every PID contains a base number and interface type (keyboard, COM port, etc.).
Enter Setup Adaptive Wired Communication When this feature is on, the scanner can automatically adapt its communication configuration to the way it is connected to the host device: Automatically enable USB/serial communication when connected to the host device via USB/serial port, respectively. Note: You must restart the scanner before this setting will take effect.
Enter Setup Chapter 5 Symbologies Introduction Every symbology (barcode type) has its own unique attributes. This chapter provides programming barcodes for configuring the scanner so that it can identify various symbologies. It is recommended to disable those that are rarely used to increase the efficiency of the scanner.
Enter Setup Enable/Disable 2D Symbologies Enable 2D Symbologies Disable 2D Symbologies Enable/Disable Postal Symbologies Enable All Postal Symbologies Disable All Postal Symbologies ** Exit Setup 68
Enter Setup 1D Twin Code 1D twin code is two 1D barcodes of a symbology or of different symbologies paralleled vertically. Both barcodes must have similar specifications and be placed closely together. There are 3 options for reading 1D twin code: Single 1D Code Only: Read either 1D code. Twin 1D Code Only: Read both 1D codes. Transmission sequence: upper 1D code followed by lower 1D code. Both Single & Twin: Read both 1D codes. If successful, transmit as twin 1D code only.
Enter Setup Surround GS1 Application Identifiers (AI’s) with Parentheses When Surround GS1 AI’s with Parentheses is selected, each application identifier (AI) contained in scanned data will be enclosed in parentheses in the output message. ** Do Not Surround GS1 AI’s with Parentheses Surround GS1 AI’s with Parentheses If Surround GS1 AI’s with Parentheses is selected, the barcode above is output as (01)00614141999996(10)10ABCEDF123456.
Enter Setup Code 128 Restore Factory Defaults Restore the Factory Defaults of Code 128 Enable/Disable Code 128 ** Enable Code 128 Disable Code 128 If the scanner fails to identify Code 128 barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable Code 128 barcode.
Enter Setup Set Length Range for Code 128 The scanner can be configured to only decode Code 128 barcodes with lengths that fall between (inclusive) the minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths. Set the Minimum Length (Default: 1) Set the Maximum Length (Default: 48) If minimum length is set to be greater than maximum length, the scanner only decodes Code 128 barcodes with either the minimum or maximum length.
Enter Setup EAN-8 Restore Factory Defaults Restore the Factory Defaults of EAN-8 Enable/Disable EAN-8 ** Enable EAN-8 Disable EAN-8 If the scanner fails to identify EAN-8 barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable EAN-8 barcode. Transmit Check Character EAN-8 is 8 digits in length with the last one as its check character used to verify the integrity of the data.
Enter Setup 2-Digit Add-On Code An EAN-8 barcode can be augmented with a two-digit add-on code to form a new one. In the example below, the part surrounded by blue dotted line is an EAN-8 barcode while the part circled by red dotted line is a two-digit add-on code. ** Disable 2-Digit Add-On Code Enable 2-Digit Add-On Code Disable 2-Digit Add-On Code: The scanner decodes EAN-8 and ignores the add-on code when presented with an EAN-8 plus 2-digit add-on barcode.
Enter Setup 5-Digit Add-On Code An EAN-8 barcode can be augmented with a five-digit add-on code to form a new one. In the example below, the part surrounded by blue dotted line is an EAN-8 barcode while the part circled by red dotted line is a five-digit add-on code. ** Disable 5-Digit Add-On Code Enable 5-Digit Add-On Code Disable 5-Digit Add-On Code: The scanner decodes EAN-8 and ignores the add-on code when presented with an EAN-8 plus 5-digit add-on barcode.
Enter Setup Add-On Code Required When EAN-8 Add-On Code Required is selected, the scanner will only read EAN-8 barcodes that contain add-on codes. ** EAN-8 Add-On Code Not Required EAN-8 Add-On Code Required Convert EAN-8 to EAN-13 Convert EAN-8 to EAN-13: Convert EAN-8 decoded data to EAN-13 format before transmission. After conversion, the data follows EAN-13 format and is affected by EAN-13 programming selections (e.g., Check Character).
Enter Setup EAN-13 Restore Factory Defaults Restore the Factory Defaults of EAN-13 Enable/Disable EAN-13 ** Enable EAN-13 Disable EAN-13 If the scanner fails to identify EAN-13 barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable EAN-13 barcode.
Enter Setup Transmit Check Character ** Transmit EAN-13 Check Character Do Not Transmit EAN-13 Check Character 2-Digit Add-On Code An EAN-13 barcode can be augmented with a two-digit add-on code to form a new one. In the example below, the part surrounded by blue dotted line is an EAN-13 barcode while the part circled by red dotted line is a two-digit add-on code.
Enter Setup 5-Digit Add-On Code An EAN-13 barcode can be augmented with a five-digit add-on code to form a new one. In the example below, the part surrounded by blue dotted line is an EAN-13 barcode while the part circled by red dotted line is a five-digit add-on code. ** Disable 5-Digit Add-On Code Enable 5-Digit Add-On Code Disable 5-Digit Add-On Code: The scanner decodes EAN-13 and ignores the add-on code when presented with an EAN-13 plus 5-digit add-on barcode.
Enter Setup EAN-13 Beginning with 290 Add-On Code Required This setting programs the scanner to require an add-on code (2-digit or 5-digit) on EAN-13 barcodes that begin with “290”. The following settings can be programmed: Require Add-On Code: All EAN-13 barcodes that begin with “290” must have a 2-digit or 5-digit add-on code. The EAN-13 barcode with the add-on code is then transmitted. If the required add-on code is not found, the EAN-13 barcode is discarded.
Enter Setup EAN-13 Beginning with 414/419 Add-On Code Required This setting programs the scanner to require an add-on code (2-digit or 5-digit) on EAN-13 barcodes that begin with a “414” or “419”. The following settings can be programmed: Require Add-On Code: All EAN-13 barcodes that begin with a “414” or “419” must have a 2-digit or 5-digit add-on code. The EAN-13 barcode with the add-on code is then transmitted. If the required add-on code is not found, the EAN-13 barcode is discarded.
Enter Setup EAN-13 Beginning with 977 Add-On Code Required This setting programs the scanner to require an add-on code (2-digit or 5-digit) on EAN-13 barcodes that begin with “977”. The following settings can be programmed: Require Add-On Code: All EAN-13 barcodes that begin with “977” must have a 2-digit or 5-digit add-on code. The EAN-13 barcode with the add-on code is then transmitted. If the required add-on code is not found, the EAN-13 barcode is discarded.
Enter Setup EAN-13 Beginning with 979 Add-On Code Required This setting programs the scanner to require an add-on code (2-digit or 5-digit) on EAN-13 barcodes that begin with “979”. The following settings can be programmed: Require Add-On Code: All EAN-13 barcodes that begin with “979” must have a 2-digit or 5-digit add-on code. The EAN-13 barcode with the add-on code is then transmitted. If the required add-on code is not found, the EAN-13 barcode is discarded.
Enter Setup UPC-E Restore Factory Defaults Restore the Factory Defaults of UPC-E Enable/Disable UPC-E ** Enable UPC-E0 Disable UPC-E0 Enable UPC-E1 ** Disable UPC-E1 If the scanner fails to identify UPC-E0/UPC-E1 barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable UPC-E0/UPC-E1 barcode.
Enter Setup Transmit Check Character UPC-E is 8 digits in length with the last one as its check character used to verify the integrity of the data. ** Transmit UPC-E Check Character Do Not Transmit UPC-E Check Character 2-Digit Add-On Code A UPC-E barcode can be augmented with a two-digit add-on code to form a new one. In the example below, the part surrounded by blue dotted line is a UPC-E barcode while the part circled by red dotted line is a two-digit add-on code.
Enter Setup 5-Digit Add-On Code A UPC-E barcode can be augmented with a five-digit add-on code to form a new one. In the example below, the part surrounded by blue dotted line is a UPC-E barcode while the part circled by red dotted line is a five-digit add-on code. ** Disable 5-Digit Add-On Code Enable 5-Digit Add-On Code Disable 5-Digit Add-On Code: The scanner decodes UPC-E and ignores the add-on code when presented with a UPC-E plus 5-digit add-on barcode.
Enter Setup Transmit Preamble Character Preamble characters (Country Code and System Character) can be transmitted as part of a UPC-E barcode. Select one of the following options for transmitting UPC-E preamble to the host device: transmit system character only, transmit system character and country code (“0” for USA), or transmit no preamble.
Enter Setup UPC-A Restore Factory Defaults Restore the Factory Defaults of UPC-A Enable/Disable UPC-A ** Enable UPC-A Disable UPC-A If the scanner fails to identify UPC-A barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable UPC-A barcode. Transmit Check Character UPC-A is 13 digits in length with the last one as its check character used to verify the integrity of the data.
Enter Setup 2-Digit Add-On Code A UPC-A barcode can be augmented with a two-digit add-on code to form a new one. In the example below, the part surrounded by blue dotted line is a UPC-A barcode while the part circled by red dotted line is a two-digit add-on code. ** Disable 2-Digit Add-On Code Enable 2-Digit Add-On Code Disable 2-Digit Add-On Code: The scanner decodes UPC-A and ignores the add-on code when presented with a UPC-A plus 2-digit add-on barcode.
Enter Setup 5-Digit Add-On Code A UPC-A barcode can be augmented with a five-digit add-on code to form a new one. In the example below, the part surrounded by blue dotted line is a UPC-A barcode while the part circled by red dotted line is a five-digit add-on code. ** Disable 5-Digit Add-On Code Enable 5-Digit Add-On Code Disable 5-Digit Add-On Code: The scanner decodes UPC-A and ignores the add-on code when presented with a UPC-A plus 5-digit add-on barcode.
Enter Setup Add-On Code Required When UPC-A Add-On Code Required is selected, the scanner will only read UPC-A barcodes that contain add-on codes. ** UPC-A Add-On Code Not Required UPC-A Add-On Code Required Transmit Preamble Character Preamble characters (Country Code and System Character) can be transmitted as part of a UPC-A barcode.
Enter Setup Coupon UPC-A/EAN-13 with Extended Coupon Code The following three types of coupon code + extended coupon code are supported: UPC-A (starting with “5”) + GS1-128 UPC-A (starting with “5”) + GS1 Databar EAN-13 (starting with “99”) + GS1-128 Use the appropriate barcode below to enable or disable UPC-A/EAN-13 with Extended Coupon Code. When left on the default setting (Off), the scanner treats Coupon Codes and Extended Coupon Codes as single bar codes.
Enter Setup Coupon GS1 Databar Output If you scan coupons that have both UPC and GS1 Databar codes, you may wish to scan and output only the data from the GS1 Databar code. Scan the GS1 Output On barcode below to scan and output only the GS1 Databar code data. When GS1 Output Off is selected, coupons that have both UPC and GS1 Databar codes are transmitted depending on your selection for the “UPC-A/EAN-13 with Extended Coupon Code” feature.
Enter Setup Interleaved 2 of 5 Restore Factory Defaults Restore the Factory Defaults of Interleaved 2 of 5 Enable/Disable Interleaved 2 of 5 ** Enable Interleaved 2 of 5 Disable Interleaved 2 of 5 If the scanner fails to identify Interleaved 2 of 5 barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable Interleaved 2 of 5 barcode.
Enter Setup Set Length Range for Interleaved 2 of 5 The scanner can be configured to only decode Interleaved 2 of 5 barcodes with lengths that fall between (inclusive) the minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths. Set the Minimum Length (Default: 6) Set the Maximum Length (Default: 80) If minimum length is set to be greater than maximum length, the scanner only decodes Interleaved 2 of 5 barcodes with either the minimum or maximum length.
Enter Setup Check Character Verification A check character is optional for Interleaved 2 of 5 and can be added as the last character. It is a calculated value used to verify the integrity of the data. Disable: The scanner transmits Interleaved 2 of 5 barcodes as is. Do Not Transmit Check Character After Verification: The scanner checks the integrity of all Interleaved 2 of 5 barcodes to verify that the data complies with the check character algorithm.
Enter Setup ITF-14 ITF-14 is a special kind of Interleaved 2 of 5 with a length of 14 characters and the last character as the check character. ITF-14 priority principle: Forthe Interleaved 2 of 5 barcodes with a length of 14 characters and the last character as the check character, the ITF-14 configurations shall take precedence over the Interleaved 2 of 5 settings.
Enter Setup ITF-6 ITF-6 is a special kind of Interleaved 2 of 5 with a length of 6 characters and the last character as the check character. ITF-6 priority principle: For the Interleaved 2 of 5 barcodes with a length of 6 characters and the last character as the check character, the ITF-6 configurations shall take precedence over the Interleaved 2 of 5 settings.
Enter Setup Matrix 2 of 5 Restore Factory Defaults Restore the Factory Defaults of Matrix 2 of 5 Enable/Disable Matrix 2 of 5 ** Enable Matrix 2 of 5 Disable Matrix 2 of 5 If the scanner fails to identify Matrix 2 of 5 barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable Matrix 2 of 5 barcode.
Enter Setup Set Length Range for Matrix 2 of 5 The scanner can be configured to only decode Matrix 2 of 5 barcodes with lengths that fall between (inclusive) the minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths. Set the Minimum Length (Default: 4) Set the Maximum Length (Default: 80) If minimum length is set to be greater than maximum length, the scanner only decodes Matrix 2 of 5 barcodes with either the minimum or maximum length.
Enter Setup Check Character Verification A check character is optional for Matrix 2 of 5 and can be added as the last character. It is a calculated value used to verify the integrity of the data. Disable: The scanner transmitsMatrix 2 of 5 barcodes as is. Do Not Transmit Check Character After Verification: The scanner checks the integrity of all Matrix 2 of 5 barcodes to verify that the data complies with the check character algorithm.
Enter Setup Code 39 Restore Factory Defaults Restore the Factory Defaults of Code 39 Enable/Disable Code 39 ** Enable Code 39 Disable Code 39 If the scanner fails to identify Code 39 barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable Code 39 barcode.
Enter Setup Set Length Range for Code 39 The scanner can be configured to only decode Code 39 barcodes with lengths that fall between (inclusive) the minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths. Set the Minimum Length (Default: 1) Set the Maximum Length (Default: 48) If minimum length is set to be greater than maximum length, the scanner only decodes Code 39 barcodes with either the minimum or maximum length.
Enter Setup Check Character Verification A check character is optional for Code 39 and can be added as the last character. It is a calculated value used to verify the integrity of the data. Disable: The scanner transmits Code 39 barcodes as is. Do Not Transmit Check Character After Verification: The scanner checks the integrity of all Code 39 barcodes to verify that the data complies with the check character algorithm.
Enter Setup Transmit Start/Stop Character Code 39 uses an asterisk (*) for both the start and the stop characters. You can choose whether or not to transmit the start/stop characters by scanning the appropriate barcode below. ** Do Not Transmit Start/Stop Character Transmit Start/Stop Character Enable/Disable Code 39 Full ASCII The scanner can be configured to identify all ASCII characters by scanning the appropriate barcode below.
Enter Setup Enable/Disable Code 32 (Italian Pharma Code) Code 32 is a variant of Code 39 used by the Italian pharmaceutical industry. Scan the appropriate bar code below to enable or disable Code 32. Code 39 must be enabled and Code 39 check character verification must be disabled for this parameter to function. ** Disable Code 32 Enable Code 32 Code 32 Prefix Scan the appropriate barcode below to enable or disable adding the prefix character “A” to all Code 32 barcodes.
Enter Setup Transmit Code 32 Start/Stop Character Code 32 must be enabled for this parameter to function. ** Do Not Transmit Code 32 Start/Stop Character Transmit Code 32 Start/Stop Character Transmit Code 32 Check Character Code 32 must be enabled for this parameter to function.
Enter Setup Codabar Restore Factory Defaults Restore the Factory Defaults of Codabar Enable/Disable Codabar ** Enable Codabar Disable Codabar If the scanner fails to identify Codabar barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable Codabar barcode.
Enter Setup Set Length Range for Codabar The scanner can be configured to only decode Codabar barcodes with lengths that fall between (inclusive) the minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths. Set the Minimum Length (Default: 2) Set the Maximum Length (Default: 60) If minimum length is set to be greater than maximum length, the scanner only decodes Codabar barcodes with either the minimum or maximum length.
Enter Setup Check Character Verification A check character is optional for Codabar and can be added as the last character. It is a calculated value used to verify the integrity of the data. Disable: The scanner transmits Codabar barcodes as is. Do Not Transmit Check Character After Verification: The scanner checks the integrity of all Codabar barcodes to verify that the data complies with the check character algorithm.
Enter Setup Start/Stop Character You can set the start/stop characters and choose whether or not to transmit the start/stop characters by scanning the appropriate barcode below.
Enter Setup Code 93 Restore Factory Defaults Restore the Factory Defaults of Code 93 Enable/Disable Code 93 Enable Code 93 ** Disable Code 93 If the scanner fails to identify Code 93 barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable Code 93 barcode.
Enter Setup Set Length Range for Code 93 The scanner can be configured to only decode Code 93 barcodes with lengths that fall between (inclusive) the minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths. Set the Minimum Length (Default: 1) Set the Maximum Length (Default: 48) If minimum length is set to be greater than maximum length, the scanner only decodes Code 93 barcodes with either the minimum or maximum length.
Enter Setup Check Character Verification Check characters are optional for Code 93 and can be added as the last two characters, which are calculated values used to verify the integrity of the data. Disable: The scanner transmits Code 93 barcodes as is. Do Not Transmit Check Character After Verification: The scanner checks the integrity of all Code 93 barcodes to verify that the data complies with the check character algorithm.
Enter Setup China Post 25 Restore Factory Defaults Restore the Factory Defaults of China Post 25 Enable/Disable China Post 25 Enable China Post 25 ** Disable China Post 25 If the scanner fails to identify China Post 25 barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable China Post 25 barcode.
Enter Setup Set Length Range for China Post 25 The scanner can be configured to only decode China Post 25 barcodes with lengths that fall between (inclusive) the minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths. Set the Minimum Length (Default: 1) Set the Maximum Length (Default: 48) If minimum length is set to be greater than maximum length, the scanner only decodes China Post 25 barcodes with either the minimum or maximum length.
Enter Setup Check Character Verification A check character is optional for China Post 25 and can be added as the last character. It is a calculated value used to verify the integrity of the data. Disable: The scanner transmits China Post 25 barcodes as is. Do Not Transmit Check Character After Verification: The scanner checks the integrity of all China Post 25 barcodes to verify that the data complies with the check character algorithm.
Enter Setup GS1-128 (UCC/EAN-128) Restore Factory Defaults Restore the Factory Defaults of GS1-128 Enable/Disable GS1-128 ** Enable GS1-128 Disable GS1-128 If the scanner fails to identify GS1-128 barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable GS1-128 barcode.
Enter Setup Set Length Range for GS1-128 The scanner can be configured to only decode GS1-128 barcodes with lengths that fall between (inclusive) the minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths. Set the Minimum Length (Default: 1) Set the Maximum Length (Default: 48) If minimum length is set to be greater than maximum length, the scanner only decodes GS1-128 barcodes with either the minimum or maximum length.
Enter Setup GS1 Databar (RSS) Restore Factory Defaults Restore the Factory Defaults of GS1 Databar Enable/Disable GS1 Databar ** Enable GS1 Databar Disable GS1 Databar If the scanner fails to identify GS1 Databar barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable GS1 Databar barcode.
Enter Setup GS1 Composite (EAN·UCC Composite) Restore Factory Defaults Restore the Factory Defaults of GS1 Composite Enable/Disable GS1 Composite Enable GS1 Composite ** Disable GS1 Composite If the scanner fails to identify GS1 Composite barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable GS1 Composite barcode.
Enter Setup Code 11 Restore Factory Defaults Restore the Factory Defaults of Code 11 Enable/Disable Code 11 Enable Code 11 ** Disable Code 11 If the scanner fails to identify Code 11 barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable Code 11 barcode.
Enter Setup Set Length Range for Code 11 The scanner can be configured to only decode Code 11 barcodes with lengths that fall between (inclusive) the minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths. Set the Minimum Length (Default: 4) Set the Maximum Length (Default: 48) If minimum length is set to be greater than maximum length, the scanner only decodes Code 11 barcodes with either the minimum or maximum length.
Enter Setup Check Character Verification Check characters are optional for Code 11 and can be added as the last one or two characters, which are calculated values used to verify the integrity of the data. If the Disable option is enabled, the scanner transmits Code 11 barcodes as is.
Enter Setup Transmit Check Character Do Not Transmit Code 11 Check Character ** Transmit Code 11 Check Character If you select a check character algorithm and the Do Not Transmit Check Character option, Code 11 barcodes with a length that is less than the configured minimum length after having the check character(s) excluded will not be decoded.
Enter Setup ISBN Restore Factory Defaults Restore the Factory Defaults of ISBN Enable/Disable ISBN Enable ISBN ** Disable ISBN If the scanner fails to identify ISBN barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable ISBN barcode.
Enter Setup ISSN Restore Factory Defaults Restore the Factory Defaults of ISSN Enable/Disable ISSN Enable ISSN ** Disable ISSN If the scanner fails to identify ISSN barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable ISSN barcode.
Enter Setup Industrial 25 Restore Factory Defaults Restore the Factory Defaults of Industrial 25 Enable/Disable Industrial 25 Enable Industrial 25 ** Disable Industrial 25 If the scanner fails to identify Industrial 25 barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable Industrial 25 barcode.
Enter Setup Set Length Range for Industrial 25 The scanner can be configured to only decode Industrial 25 barcodes with lengths that fall between (inclusive) the minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths. Set the Minimum Length (Default: 6) Set the Maximum Length (Default: 48) If minimum length is set to be greater than maximum length, the scanner only decodes Industrial 25 barcodes with either the minimum or maximum length.
Enter Setup Check Character Verification A check character is optional for Industrial 25 and can be added as the last character. It is a calculated value used to verify the integrity of the data. Disable: The scanner transmits Industrial 25 barcodes as is. Do Not Transmit Check Character After Verification: The scanner checks the integrity of all Industrial 25 barcodes to verify that the data complies with the check character algorithm.
Enter Setup Standard 25 Restore Factory Defaults Restore the Factory Defaults of Standard 25 Enable/Disable Standard 25 Enable Standard 25 ** Disable Standard 25 If the scanner fails to identify Standard 25 barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable Standard 25 barcode.
Enter Setup Set Length Range for Standard 25 The scanner can be configured to only decode Standard 25 barcodes with lengths that fall between (inclusive) the minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths. Set the Minimum Length (Default: 6) Set the Maximum Length (Default: 48) If minimum length is set to be greater than maximum length, the scanner only decodes Standard 25 barcodes with either the minimum or maximum length.
Enter Setup Check Character Verification A check character is optional for Standard 25 and can be added as the last character. It is a calculated value used to verify the integrity of the data. Disable: The scanner transmits Standard 25 barcodes as is. Do Not Transmit Check Character After Verification: The scanner checks the integrity of all Standard 25 barcodes to verify that the data complies with the check character algorithm.
Enter Setup Plessey Restore Factory Defaults Restore the Factory Defaults of Plessey Enable/Disable Plessey Enable Plessey ** Disable Plessey If the scanner fails to identify Plessey barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable Plessey barcode.
Enter Setup Set Length Range for Plessey The scanner can be configured to only decode Plessey barcodes with lengths that fall between (inclusive) the minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths. Set the Minimum Length (Default: 4) Set the Maximum Length (Default: 48) If minimum length is set to be greater than maximum length, the scanner only decodes Plessey barcodes with either the minimum or maximum length.
Enter Setup Check Character Verification Check characters are optional for Plessey and can be added as the last two characters, which are calculated values used to verify the integrity of the data. Disable: The scanner transmits Plessey barcodes as is. Do Not Transmit Check Character After Verification: The scanner checks the integrity of all Plessey barcodes to verify that the data complies with the check character algorithm.
Enter Setup MSI-Plessey Restore Factory Defaults Restore the Factory Defaults of MSI-Plessey Enable/Disable MSI-Plessey Enable MSI-Plessey ** Disable MSI-Plessey If the scanner fails to identify MSI-Plessey barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable MSI-Plessey barcode.
Enter Setup Set Length Range for MSI-Plessey The scanner can be configured to only decode MSI-Plessey barcodes with lengths that fall between (inclusive) the minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths. Set the Minimum Length (Default: 4) Set the Maximum Length (Default: 48) If minimum length is set to be greater than maximum length, the scanner only decodes MSI-Plessey barcodes with either the minimum or maximum length.
Enter Setup Check Character Verification Check characters are optional for MSI-Plessey and can be added as the last one or two characters, which are calculated values used to verify the integrity of the data. If the Disable option is enabled, the scanner transmits MSI-Plessey barcodes as is.
Enter Setup Transmit Check Character ** Transmit MSI-Plessey Check Character Do Not Transmit MSI-Plessey Check Character If you select a check character algorithm and the Do Not Transmit Check Character option, MSI-Plessey barcodes with a length that is less than the configured minimum length after having the check character(s) excluded will not be decoded.
Enter Setup AIM 128 Restore Factory Defaults Restore the Factory Defaults of AIM 128 Enable/Disable AIM 128 Enable AIM 128 ** Disable AIM 128 If the scanner fails to identify AIM 128 barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable AIM 128 barcode.
Enter Setup Set Length Range for AIM 128 The scanner can be configured to only decode AIM 128 barcodes with lengths that fall between (inclusive) the minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths. Set the Minimum Length (Default: 1) Set the Maximum Length (Default: 48) If minimum length is set to be greater than maximum length, the scanner only decodes AIM 128 barcodes with either the minimum or maximum length.
Enter Setup ISBT 128 Restore Factory Defaults Restore the Factory Defaults of ISBT 128 Enable/Disable ISBT 128 Enable ISBT 128 ** Disable ISBT 128 If the scanner fails to identify ISBT 128 barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable ISBT 128 barcode.
Enter Setup Code 49 Restore Factory Defaults Restore the Factory Defaults of Code 49 Enable/Disable Code 49 Enable Code 49 ** Disable Code 49 If the scanner fails to identify Code 49 barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable Code 49 barcode.
Enter Setup Set Length Range for Code 49 The scanner can be configured to only decode Code 49 barcodes with lengths that fall between (inclusive) the minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths. Set the Minimum Length (Default: 1) Set the Maximum Length (Default: 80) If minimum length is set to be greater than maximum length, the scanner only decodes Code 49 barcodes with either the minimum or maximum length.
Enter Setup Code 16K Restore Factory Defaults Restore the Factory Defaults of Code 16K Enable/Disable Code 16K Enable Code 16K ** Disable Code 16K If the scanner fails to identify Code 16K barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable Code 16K barcode.
Enter Setup Set Length Range for Code 16K The scanner can be configured to only decode Code 16K barcodes with lengths that fall between (inclusive) the minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths. Set the Minimum Length (Default: 1) Set the Maximum Length (Default: 80) If minimum length is set to be greater than maximum length, the scanner only decodes Code 16K barcodes with either the minimum or maximum length.
Enter Setup COOP 25 Restore Factory Defaults Restore the Factory Defaults of COOP 25 Enable/Disable COOP 25 Enable COOP 25 ** Disable COOP 25 If the scanner fails to identify COOP 25 barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable COOP 25 barcode.
Enter Setup Set Length Range for Code 16K The scanner can be configured to only decode COOP 25 barcodes with lengths that fall between (inclusive) the minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths. Set the Minimum Length (Default: 4) Set the Maximum Length (Default: 80) If minimum length is set to be greater than maximum length, the scanner only decodes COOP 25 barcodes with either the minimum or maximum length.
Enter Setup Check Character Verification ** Disable Do Not Transmit Check Character After Verification Transmit Check Character After Verification ** Exit Setup 150
Enter Setup PDF417 Restore Factory Defaults Restore the Factory Defaults of PDF417 Enable/Disable PDF417 ** Enable PDF417 Disable PDF417 If the scanner fails to identify PDF417 barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable PDF417 barcode.
Enter Setup Set Length Range for PDF417 The scanner can be configured to only decode PDF417 barcodes with lengths that fall between (inclusive) the minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths. Set the Minimum Length (Default: 1) Set the Maximum Length (Default: 2710) Minimum length is not allowed to be greater than maximum length.
Enter Setup PDF417 Twin Code PDF417 twin code is 2 PDF417 barcodes paralleled vertically or horizontally. They must both be either regular or inverse barcodes. They must have similar specifications and be placed closely together. There are 3 options for reading PDF417 twin codes: Single PDF417 Only: Read either PDF417 code. Twin PDF417 Only: Read both PDF417 codes. Both Single & Twin: Read both PDF417 codes. If successful, transmit as twin PDF417 only. Otherwise, try single PDF417 only.
Enter Setup PDF417 Inverse Regular barcode: Dark bars on a bright background. Inverse barcode: Bright bars on a dark background.
Enter Setup PDF417 ECI Output Disable PDF417 ECI Output ** Enable PDF417 ECI Output 155 ** Exit Setup
Enter Setup Micro PDF417 Restore Factory Defaults Restore the Factory Defaults of Micro PDF417 Enable/Disable Micro PDF417 Enable Micro PDF417 ** Disable Micro PDF417 If the scanner fails to identify Micro PDF417 barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable Micro PDF417 barcode.
Enter Setup Set Length Range for Micro PDF417 The scanner can be configured to only decode Micro PDF417 barcodes with lengths that fall between (inclusive) the minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths. Set the Minimum Length (Default: 1) Set the Maximum Length (Default: 366) Minimum length is not allowed to be greater than maximum length.
Enter Setup QR Code Restore Factory Defaults Restore the Factory Defaults of QR Code Enable/Disable QR Code ** Enable QR Code Disable QR Code If the scanner fails to identify QR Code barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable QR Code barcode.
Enter Setup Set Length Range for QR Code The scanner can be configured to only decode QR Code barcodes with lengths that fall between (inclusive) the minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths. Set the Minimum Length (Default: 1) Set the Maximum Length (Default: 7089) Minimum length is not allowed to be greater than maximum length.
Enter Setup QR Twin Code QR twin code is 2 QR barcodes paralleled vertically or horizontally. They must both be either regular or inverse barcodes. They must have similar specifications and be placed closely together. There are 3 options for reading QR twin codes: Single QR Only: Read either QR code. Twin QR Only: Read both QR codes. Transmission sequence: left (upper) QR code followed by right (lower) QR code. Both Single & Twin: Read both QR codes. If successful, transmit as twin QR only.
Enter Setup QR Inverse Regular barcode: Dark bars on a bright background. Inverse barcode: Bright bars on a dark background.
Enter Setup QR ECI Output Disable QR ECI Output ** Enable QR ECI Output ** Exit Setup 162
Enter Setup Micro QR Code Restore Factory Defaults Restore the Factory Defaults of Micro QR Enable/Disable Micro QR ** Enable Micro QR Disable Micro QR If the scanner fails to identify Micro QR barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable Micro QR barcode.
Enter Setup Set Length Range for Micro QR The scanner can be configured to only decode Micro QR barcodes with lengths that fall between (inclusive) the minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths. Set the Minimum Length (Default: 1) Set the Maximum Length (Default: 35) Minimum length is not allowed to be greater than maximum length.
Enter Setup Aztec Restore Factory Defaults Restore the Factory Defaults of Aztec Code Enable/Disable Aztec Code Enable Aztec Code ** Disable Aztec Code If the scanner fails to identify Aztec Code barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable Aztec Code barcode.
Enter Setup Set Length Range for Aztec Code The scanner can be configured to only decode Aztec barcodes with lengths that fall between (inclusive) the minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths. Set the Minimum Length (Default: 1) Set the Maximum Length (Default: 3832) Minimum length is not allowed to be greater than maximum length.
Enter Setup Read Multi-barcodes on an Image There are three options: Mode 1: Read one barcode only. Mode 2: Read fixed number of barcodes only. Mode 3: Composite Reading. Read fixed number of barcodes first. If unsuccessful, read one barcode only.
Enter Setup Set the Number of Barcodes ** 1 2 3 4 5 6 7 8 ** Exit Setup 168
Enter Setup Character Encoding ** Default Character Encoding UTF-8 Aztec ECI Output Disable Aztec ECI Output ** Enable Aztec ECI Output 169 ** Exit Setup
Enter Setup Data Matrix Restore Factory Defaults Restore the Factory Defaults of Data Matrix Enable/Disable Data Matrix ** Enable Data Matrix Disable Data Matrix If the scanner fails to identify Data Matrix barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable Data Matrix barcode.
Enter Setup Set Length Range for Data Matrix The scanner can be configured to only decode Data Matrix barcodes with lengths that fall between (inclusive) the minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths. Set the Minimum Length (Default: 1) Set the Maximum Length (Default: 3116) Minimum length is not allowed to be greater than maximum length.
Enter Setup Data Matrix Twin Code Data Matrix twin code is 2 Data Matrix barcodes paralleled vertically or horizontally. They must both be either regular or inverse barcodes. They must have similar specifications and be placed closely together. There are 3 options for reading Data Matrix twin codes: Single Data Matrix Only: Read either Data Matrix code. Twin Data Matrix Only: Read both Data Matrix codes. Transmission sequence: left (upper) Data Matrix code followed by right (lower) Data Matrix code.
Enter Setup Rectangular Barcode Data Matrix has two formats: Square barcodes having the same amount of modules in length and width: 10*10, 12*12.... 144*144. Rectangular barcodes having different amounts of models in length and width: 6*16, 6*14...14*22. ** Enable Rectangular Barcode Disable Rectangular Barcode Data Matrix Inverse Regular barcode: Dark bars on a bright background. Inverse barcode: Bright bars on a dark background.
Enter Setup Character Encoding ** Default Character Encoding UTF-8 Data Matrix ECI Output Disable Data Matrix ECI Output ** Enable Data Matrix ECI Output ** Exit Setup 174
Enter Setup Maxicode Restore Factory Defaults Restore the Factory Defaults of Maxicode Enable/Disable Maxicode Enable Maxicode ** Disable Maxicode If the scanner fails to identify Maxicode barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable Maxicode barcode.
Enter Setup Set Length Range for Maxicode The scanner can be configured to only decode Maxicode barcodes with lengths that fall between (inclusive) the minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths. Set the Minimum Length (Default: 1) Set the Maximum Length (Default:150) Minimum length is not allowed to be greater than maximum length.
Enter Setup Chinese Sensible Code Restore Factory Defaults Restore the Factory Defaults of Chinese Sensible Code Enable/Disable Chinese Sensible Code Enable Chinese Sensible Code ** Disable Chinese Sensible Code If the scanner fails to identify Chinese Sensible Code barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable Chinese Sensible Code barcode.
Enter Setup Set Length Range for Chinese Sensible Code The scanner can be configured to only decode Chinese Sensible Code barcodes with lengths that fall between (inclusive) the minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths. Set the Minimum Length (Default: 1) Set the Maximum Length (Default: 7827) Minimum length is not allowed to be greater than maximum length.
Enter Setup Chinese Sensible Twin Code Chinese Sensible twin code is 2 Chinese Sensible barcodes paralleled vertically or horizontally. They must both be either regular or inverse barcodes. They must have similar specifications and be placed closely together. There are 3 options for reading Chinese Sensible twin codes: Single Chinese Sensible Code Only: Read either Chinese Sensible code. Twin Chinese Sensible Code Only: Read both Chinese Sensible codes.
Enter Setup Chinese Sensible Code Inverse Regular barcode: Dark bars on a bright background. Inverse barcode: Bright bars on a dark background.
Enter Setup GM Code Restore Factory Defaults Restore the Factory Defaults of GM Enable/Disable GM Enable GM ** Disable GM If the scanner fails to identify GM barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable GM barcode.
Enter Setup Set Length Range for GM The scanner can be configured to only decode GM barcodes with lengths that fall between (inclusive) the minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths. Set the Minimum Length (Default: 1) Set the Maximum Length (Default: 2751) Minimum length is not allowed to be greater than maximum length. If you only want to read GM barcodes with a specific length, set both minimum and maximum lengths to be that desired length.
Enter Setup Code One Restore Factory Defaults Restore the Factory Defaults of Code One Enable/Disable Code One Enable Code One ** Disable Code One If the scanner fails to identify Code One barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable Code One barcode.
Enter Setup Set Length Range for Code One The scanner can be configured to only decode Code One barcodes with lengths that fall between (inclusive) the minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths. Set the Minimum Length (Default: 1) Set the Maximum Length (Default: 3550) Minimum length is not allowed to be greater than maximum length.
Enter Setup DotCode Restore Factory Defaults Restore the Factory Defaults of DotCode Enable/Disable DotCode Enable DotCode ** Disable DotCode If the scanner fails to identify DotCode barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable DotCode barcode.
Enter Setup USPS Postnet Restore Factory Defaults Restore the Factory Defaults of USPS Postnet Enable/Disable USPS Postnet Enable USPS Postnet ** Disable USPS Postnet If the scanner fails to identify USPS Postnet barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable USPS Postnet barcode.
Enter Setup USPS Intelligent Mail Restore Factory Defaults Restore the Factory Defaults of USPS Intelligent Mail Enable/Disable USPS Intelligent Mail Enable USPS Intelligent Mail ** Disable USPS Intelligent Mail If the scanner fails to identify USPS Intelligent Mail barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable USPS Intelligent Mail barcode.
Enter Setup Royal Mail Restore Factory Defaults Restore the Factory Defaults of Royal Mail Enable/Disable Royal Mail Enable Royal Mail ** Disable Royal Mail If the scanner fails to identify Royal Mail barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable Royal Mail barcode.
Enter Setup USPS Planet Restore Factory Defaults Restore the Factory Defaults of USPS Planet Enable/Disable USPS Planet Enable USPS Planet ** Disable USPS Planet If the scanner fails to identify USPS Planet barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable USPS Planet barcode.
Enter Setup KIX Post Restore Factory Defaults Restore the Factory Defaults of KIX Post Enable/Disable KIX Post Enable KIX Post ** Disable KIX Post If the scanner fails to identify KIX Post barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable KIX Post barcode.
Enter Setup Australian Postal Restore Factory Defaults Restore the Factory Defaults of Australian Postal Enable/Disable Australian Postal Enable Australian Postal ** Disable Australian Postal If the scanner fails to identify Australian Postal barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable Australian Postal barcode.
Enter Setup Japan Post Restore Factory Defaults Restore the Factory Defaults of Japan Post Enable/Disable Japan Post Enable Japan Post ** Disable Japan Post ** Exit Setup 192
Enter Setup Specific OCR-B Restore Factory Defaults Restore the Factory Defaults of Specific OCR-B Enable/Disable Specific OCR-B Enable Specific OCR-B ** Disable Specific OCR-B If the scanner fails to identify Specific OCR-B barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable Specific OCR-B barcode.
Enter Setup Chinese ID Card OCR Restore Factory Defaults Restore the Factory Defaults of Chinese ID Card OCR Enable/Disable Chinese ID Card OCR Enable Chinese ID Card OCR ** Disable Chinese ID Card OCR If the scanner fails to identify Chinese ID Card OCR barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable Chinese ID Card OCR barcode.
Enter Setup Passport OCR Restore Factory Defaults Restore the Factory Defaults of Passport OCR Enable/Disable Passport OCR Enable Passport OCR ** Disable Passport OCR If the scanner fails to identify Passport OCR barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable Passport OCR barcode.
Enter Setup China Travel Permit OCR Restore Factory Defaults Restore the Factory Defaults of China Travel Permit OCR Enable/Disable China Travel Permit OCR Enable China Travel Permit OCR ** Disable China Travel Permit OCR If the scanner fails to identify China Travel Permit OCR barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable China Travel Permit OCR barcode.
Enter Setup Chapter 6 Data Formatter Introduction You may use the Data Formatter to modify the scanner’s output. For example, you can use the Data Formatter to insert characters at certain points in barcode data or to suppress/ replace/ send certain characters in barcode data as it is scanned.
Enter Setup Step 2: Scan the Add Data Format barcode. Add Data Format Step 3: Select a label (Format_0 or Format_1 or Format_2 or Format_3). Scan a numeric barcode 0 or 1 or 2 or 3 to label this data format Format_0 or Format_1 or Format_2 or Format_3. Step 4: Select formatter command type. Specify what type of formatter commands will be used. Scan a numeric barcode “6” to select formatter command type 6.
Enter Setup Example: Program a Format_0 data format using formatter command type 6, Code 128 containing 10 characters applicable, send all characters followed by “A”. 1. Scan the Enter Setup barcode Enter the Setup mode 2. Scan the Add Data Format barcode Add a data format 3. Scan the 0 barcode Select Format_0 as the label 4. Scan the 6 barcode Select formatter command type 6 5. Scan the 9 barcode three times All interface types applicable 6. Scan the barcodes 002 Only Code 128 applicable 7.
Enter Setup Programming with Serial Commands A data format can also be created by serial commands (HEX) sent from the host device. All commands must be entered in uppercase letters. The syntax consists of the following elements: Prefix: “~0000” (HEX: 7E 01 30 30 30 30), 6 characters. Storage type: “@” (HEX: 40) or “#” (HEX: 23), 1 character.
Enter Setup Enable/Disable Data Formatter When Data Formatter is disabled, the data format you have enabled becomes invalid. ** Disable Data Formatter You may wish to require the data to conform to a data format you have created. The following settings can be applied to your data format: Enable Data Formatter, Required, Keep Prefix/Suffix: Scanned data that meets your data format requirements is modified accordingly and gets outputted along with prefixes and suffixes (if prefix and suffix are enabled).
Enter Setup Enable Data Formatter, Required, Keep Prefix/Suffix Enable Data Formatter, Required, Drop Prefix/Suffix Enable Data Formatter, Not Required, Keep Prefix/Suffix Enable Data Formatter, Not Required, Drop Prefix/Suffix Non-Match Error Beep If Non-Match Error Beep is turned ON, the scanner generates an error beep when a barcode is encountered that does not match your required data format.
Enter Setup Data Format Selection After enabling the Data Formatter, you can select a data format you want to use by scanning the appropriate barcode below.
Enter Setup Change Data Format for a Single Scan You can switch between data formats for a single scan. The next barcode is scanned using the data format selected here, then reverts to the format you have selected above. For example, you may have set your scanner to use the data format you saved as Format_3. You can switch to Format_1 for a single trigger pull by scanning the Single Scan – Format_1 barcode below. The next barcode that is scanned uses Format_1, then reverts back to Format_3.
Enter Setup Clear Data Format There are two methods to remove data format created from your scanner: Delete one data format: Scan the Clear One barcode, a numeric barcode (0-3) and the Save barcode. For example, to delete Format_2, you should scan the Clear One barcode, the 2 barcode and the Save barcode Delete all data formats: Scan the Clear All barcode.
Enter Setup Formatter Command Type 6 When working with the Data Formatter, a virtual cursor is moved along your input data string. The following commands are used to both move this cursor to different positions, and to select, replace, and insert data into the final output. For the hex value of ASCII characters involved in the commands, refer to the “ASCII Table” in Appendix.
Enter Setup F3 Send all characters up to a particular character Syntax=F3ssxx (ss: The particular character’s hex value; xx: The insert character’s hex value) Include in the output message all characters from the input message, starting with the character at the current cursor position and continuing to, but not including, the particular character “ss,” followed by character “xx.” The cursor is moved forward to the “ss” character.
Enter Setup B9 Send all characters up to a particular string Syntax=B9nnnns...s (nnnn: The length of the particular string; s...s: The hex value of each character in the particular string) Include in the output message all characters from the input message, starting with the character at the current cursor position and continuing to, but not including, the particular string “s...s.” The cursor is moved forward to the beginning of the “s...s” string.
Enter Setup E9 and F4 Example: Send all but the last characters, followed by 2 tabs Send all characters except for the last 8 from the barcode above, followed by 2 tabs.
Enter Setup B3 and B4 Example: Insert the symbology name and length Send the symbology name and length before the barcode data from the barcode above. Break up these insertions with spaces. End with a carriage return.
Enter Setup F5 Example: Move the cursor forward and send the data Move the cursor forward 3 characters, then send the rest of the barcode data from the barcode above. End with a carriage return.
Enter Setup Search Commands F8 Search forward for a character Syntax=F8xx (xx: The search character’s hex value) Search the input message forward for “xx” character from the current cursor position, leaving the cursor pointing to the “xx” character. F8 Example: Send barcode data that starts after a particular character Search for the letter “D” in barcodes and send all the data that follows, including the “D”.
Enter Setup B0 Search forward for a string Syntax=B0nnnnS (nnnn: The string length (up to 9999); S: The ASCII hex value of each character in the string) Search forward for “S” string from the current cursor position, leaving cursor pointing to “S” string. For example, B0000454657374 will search forward for the first occurrence of the 4-character string “Test.
Enter Setup E6 Search forward for a non-matching character Syntax=E6xx (xx: The search character’s hex value) Search the input message forward for the first non-“xx” character from the current cursor position, leaving the cursor pointing to the non-“xx” character. E6 Example: Remove zeros at the beginning of barcode data This example shows a barcode that has been zero filled. You may want to ignore the zeros and send all the data that follows.
Enter Setup Miscellaneous Commands FB Suppress characters Syntax=FBnnxxyy..zz (nn: The numeric value (00-15) for the number of suppressed characters; xxyy..zz: The hex value of the characters to be suppressed) Suppress all occurrences of up to 15 different characters, starting at the current cursor position, as the cursor is advanced by other commands. FB Example: Remove spaces in barcode data This example shows a barcode that has spaces in the data.
Enter Setup E4 Example: Replace zeros with CRs in barcode data If the barcode has characters that the host application does not want included, you can use the E4 command to replace those characters with something else. In this example, you will replace the zeros in the barcode above with carriage returns.
Enter Setup BA Replace a string with another Syntax=BAnnNN1SS1NN2SS2 nn: The count of replacements to be made, if nn=00 or nn>=the number of occurrences of a string to be replaced, then replace all occurrences of that string. NN1: The length of the string to be replaced, NN1>0. SS1: The ASCII hex value of each character in the string to be replaced. NN2: The length of replacement string, NN2>=0. To replace string “SS1” with NUL (i.e. deIete string “SS1”), you should set NN2 to 00 and leave out SS2.
Enter Setup 41 is the hex value for A (character in the replacement string) 42 is the hex value for B (character in the replacement string) 43 is the hex value for C (character in the replacement string) F1 is the “Send all characters” command 00 is the hex value for a NUL The data is output as: 1ABC4AbcABCR01ABCU BA Example: Remove only the first occurrence of “23”s in barcode data If the barcode has a string of characters that the host application wants removed, you can use the BA command to replace the
Enter Setup EF Insert a delay Syntax=EFnnnn (nnnn: The delay in 5ms increments, up to 9999) Inserts a delay of up to 49,995 milliseconds (in multiples of 5), starting from the current cursor position. This command can only be used with USB HID Keyboard. EF Example: Insert a delay of 1s between the 5th and 6th character Send the first 5 characters in a barcode, wait for 1s, then send the rest of the barcode data.
Enter Setup B5 Insert key strokes Syntax=B5nnssxx (nn: The number of keys pressed (without key modifiers); ss: the key modifier from the table below; xx: the key number from the “Unicode Key Maps” in Appendix.) Insert a key stroke or combination of key strokes. Key strokes are dependent on your keyboard (see the “Unicode Key Maps” in Appendix). This command can only be used with USB HID Keyboard.
Enter Setup Chapter 7 Prefix & Suffix Introduction A 1D barcode could contain digits, letters, symbols, etc. A 2D barcode could contain more data, such as Chinese characters and other multi-byte characters. However, in real applications, they do not and should not have all information we need, such as barcode type, data acquisition time and delimiter, in order to keep the barcodes short and flexible. Preffix and suffix are how to fulfill the needs mentioned above.
Enter Setup Global Settings Enable/Disable All Prefixes/Suffixes Disable All Prefixes/Suffixes: Transmit barcode data with no prefix/suffix. Enable All Prefixes/Suffixes: Allow to append Code ID prefix, AIM ID prefix, custom prefix/suffix and terminating character to the barcode data before the transmission.
Enter Setup Custom Prefix Enable/Disable Custom Prefix If custom prefix is enabled, you are allowed to append to the data a user-defined prefix that cannot exceed 10 characters. For example, if the custom prefix is “AB” and the barcode data is “123”, the Host will receive “AB123”.
Enter Setup AIM ID Prefix AIM (Automatic Identification Manufacturers) ID defines symbology identifier (For the details, see the “AIM ID Table” section in Appendix). If AIM ID prefix is enabled, the scanner will add the symbology identifier before the scanned data after decoding. ** Disable AIM ID Prefix Enable AIM ID Prefix AIM ID is not user programmable.
Enter Setup Code ID Prefix Code ID can also be used to identify barcode type. Unlike AIM ID, Code ID is user programmable. Code ID can only consist of one or two English letters. ** Disable Code ID Prefix Enable Code ID Prefix Restore All Default Code IDs For the information of default Code IDs, see the “Code ID Table” section in Appendix. Restore All Default Code IDs Modify Code ID See the examples below to learn how to modify a Code ID and restore the default Code IDs of all symbologies.
Enter Setup Modify PDF417 Code ID to be “p” (HEX: 0x70): 1. Scan the Enter Setup barcode. 2. Scan the Modify PDF417 Code ID barcode. 3. Scan the numeric barcodes “7” and “0” from the “Digit Barcodes” section in Appendix. 4. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix. 5. Scan the Exit Setup barcode. Restore the default Code IDs of all symbologies: 1. Scan the Enter Setup barcode. 2. Scan the Restore All Default Code IDs barcode. 3. Scan the Exit Setup barcode.
Enter Setup 1D symbologies: Modify Code 128 Code ID Modify GS1-128 Code ID Modify EAN-8 Code ID Modify EAN-13 Code ID Modify UPC-E Code ID Modify UPC-A Code ID Modify Interleaved 2 of 5 Code ID 227 ** Exit Setup
Enter Setup Modify ITF-14 Code ID Modify ITF-6 Code ID Modify Matrix 2 of 5 Code ID Modify Code 39 Code ID Modify Codabar Code ID Modify Code 93 Code ID Modify China Post 25 Code ID Modify AIM 128 Code ID ** Exit Setup 228
Enter Setup Modify ISBT 128 Code ID Modify COOP 25 Code ID Modify ISSN Code ID Modify ISBN Code ID Modify Industrial 25 Code ID Modify Standard 25 Code ID Modify Plessey Code ID Modify Code 11 Code ID 229 ** Exit Setup
Enter Setup Modify MSI-Plessy Code ID Modify GS1 Composite Code ID Modify GS1 Databar Code ID Modify Code 49 Code ID Modify Code 16K Code ID ** Exit Setup 230
Enter Setup 2D symbologies: Modify PDF417 Code ID Modify QR Code ID Modify Aztec Code ID Modify Data Matrix Code ID Modify Maxicode Code ID Modify Chinese Sensible Code ID Modify GM Code ID 231 ** Exit Setup
Enter Setup Modify Micro PDF417 Code ID Modify Micro QR Code ID Modify Code One Code ID ** Exit Setup 232
Enter Setup Postal symbologies: Modify USPS Postnet Code ID Modify USPS Inteligent Mail Code ID Modify Royal Mail Code ID Modify USPS Planet Code ID Modify KIX Post Code ID Modify Australian Postal Code ID Modify Japan Post Code ID 233 ** Exit Setup
Enter Setup OCR: Modify Specific OCR-B Code ID Modify Chinese ID Card OCR Code ID Modify Passport OCR Code ID Modify China Travel Permit OCR Code ID ** Exit Setup 234
Enter Setup Custom Suffix Enable/Disable Custom Suffix If custom suffix is enabled, you are allowed to append to the data a user-defined suffix that cannot exceed 10 characters. For example, if the custom suffix is “AB” and the barcode data is “123”, the Host will receive “123AB”.
Enter Setup Data Packing Introduction Data packing is designed for a specific group of users who want to have the data packed before transmission. Data packing influences data format, so it is advised to disable this feature when it is not required. Data Packing Options Disable Data Packing: Transmit decoded data in raw format (unpacketed). Enable Data Packing, Format 1: Transmit decoded data with the packet format 1 defined below.
Enter Setup ** Disable Data Packing Enable Data Packing, Format 1 Enable Data Packing, Format 2 237 ** Exit Setup
Enter Setup Terminating Character Suffix Enable/Disable Terminating Character Suffix A terminating character such as carriage return (CR) or carriage return/line feed pair (CRLF) can only be used to mark the end of data, which means nothing can be added after it.
Enter Setup Set the terminating character suffix to 0x0A: 1. Scan the Enter Setup barcode. 2. Scan the Set Terminating Character Suffix barcode. 3. Scan the numeric barcodes “0” and “A” from the “Digit Barcodes” section in Appendix. 4. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix. 5. Scan the Enable Terminating Character Suffix barcode. 6. Scan the Exit Setup barcode.
Enter Setup Chapter 8 USA Driver License Parsing The HP Barcode Scanner N-Series Configuration Utility can be used to configure settings for the USA Driver License Parsing function. In the HP Barcode Scanner N-Series Configuration Utility, select the 3. DATA FORMATTING tab, and then select the USA Driver License Parsing tab to see the available settings. To enable the editing of barcode data, select Advanced Formatting/Label Edit Script Enable.
Enter Setup Chapter 9 Batch Programming Introduction Batch programming enables users to integrate a batch of commands into a single batch barcode. Listed below are batch programming rules: 1. Command format: Command + Parameter Value. 2. Each command is terminated by a semicolon (;). Note that there is no space between a command and its terminator semicolon. 3. Use the barcode generator software to generate a 2D batch barcode.
Enter Setup Create a Batch Command A batch command may contain a number of individual commands each of which is terminated by a semicolon (;). For more information, refer to the “Use of Programming Command” section in Chapter 3. Create a Batch Barcode Batch barcodes can be produced in the format of PDF417, QR Code or Data Matrix. Example: Create a batch barcode for inernal lllumination Always On, Sense Mode, Decode Session Timeout = 2s: 1. Input the following commands: @ILLSCN2;SCNMOD2;ORTSET2000; 2.
Enter Setup Use Batch Barcode To put a batch barcode into use, scan the following barcodes. (Use the example above.
Appendix Digit Barcodes 0~9 0 1 2 3 4 5
6 7 8 9
A~F A B C D E F
Save/Cancel Barcodes After reading numeric barcode(s), you need to scan the Save barcode to save the data. If you scan the wrong digit(s), you can either scan the Cancel barcode and then start the configuration all over again, or scan the Delete the Last Digit barcode and then the correct digit, or scan the Delete All Digits barcode and then the digits you want.
Factory Defaults Table Parameter Factory Default Remark System Settings Barcode Programming Disabled (Exit Setup) Programming Barcode Data Do not transmit Internal Illumination Normal External Illumination Off Aiming Normal Good Read LED On Good Read LED Duration Short (20ms) Power On Beep On Good Read Beep On Good Read Beep Duration Medium (80ms) Good Read Beep Frequency Medium (2730Hz) Good Read Beep Volume Loud Scan Mode Sense Mode Decode Session Timeout 3,000ms.
Auto Sleep Disabled Time Period from Idle to Sleep 15ms Default Interface USB HID Keyboard USB Interface USB Country Keyboard US keyboard USB HID Keyboard Beep on Unknown Character Off USB HID Keyboard Emulate ALT+Keypad Off USB HID Keyboard Code Page Code Page 1252 (West European Latin) USB HID Keyboard Unicode Encoding Off USB HID Keyboard Emulate Keypad with Leading Zero On USB HID Keyboard Function Key Mapping Disable USB HID Keyboard Inter-Keystroke Delay No Delay USB HID K
Check Character Transmit 2-Digit Add-On Code Disabled 5-Digit Add-On Code Disabled Add-On Code Not Required EAN-13 Beginning with 290 Add-On Code Required EAN-13 Beginning with 378/379 Add-On Code Required EAN-13 Beginning with 414/419 Add-On Code Required EAN-13 Beginning with 434/439 Add-On Code Required EAN-13 Beginning with 977 Add-On Code Required EAN-13 Beginning with 978 Add-On Code Required EAN-13 Beginning with 979 Add-On Code Required EAN-13 Beginning with 290 Add-On Code Required Do Not
UPC-A/EAN-13 with Extended Coupon Off Code Coupon GS1 DataBar Output Off Interleaved 2 of 5 Interleaved 2 of 5 Enabled Maximum Length 80 Minimum Length 6 Check Character Verification Disabled No less than 4 ITF-14 ITF-14 Disabled ITF-6 ITF-6 Disabled Matrix 2 of 5 Matrix 2 of 5 Enabled Maximum Length 80 Minimum Length 4 Check Character Verification Disabled Code 39 Code 39 Enabled Maximum Length 48 Minimum Length 1 Check Character Verification Disabled Start/Stop Character
Code 93 Disabled Maximum Length 48 Minimum Length 1 Check Character Verification Do Not Transmit Check Character After Verification China Post 25 China Post 25 Disabled Maximum Length 48 Minimum Length 1 Check Character Verification Disabled GS1-128 (UCC/EAN-128) GS1-128 Enabled Maximum Length 48 Minimum Length 1 GS1 Databar GS1 Databar Enabled Application Identifier “01” Transmit EAN•UCC Composite GS1 Composite Disabled UPC/EAN Composite Disabled Code 11 Code 11 Disabled Max
Standard 25 Disabled Maximum Length 48 Minimum Length 6 Check Character Verification Disabled No less than 4 Plessey Plessey Disabled Maximum Length 48 Minimum Length 4 Check Character Verification Disabled No less than 4 MSI-Plessey MSI-Plessey Disabled Maximum Length 48 Minimum Length 4 Check Character Verification One Check Character, MOD10 Check Character Transmit AIM 128 AIM 128 Disabled Maximum Length 48 Minimum Length 1 ISBT 128 ISBT 128 Disabled Code 49 Code 49 D
Maximum Length 2710 Minimum Length 1 PDF417 Twin Code Single PDF417 Only PDF417 Inverse Decode Regular PDF417 Barcodes Only Character Encoding Default Character Encoding PDF417 ECI Output Enabled Micro PDF417 Micro PDF417 Disabled Maximum Length 366 Minimum Length 1 QR Code QR Code Enabled Maximum Length 7089 Minimum Length 1 QR Twin Code Single QR Only QR Inverse Decode Regular QR Barcodes Only Character Encoding Default Character Encoding QR ECI Output Enabled Micro QR Code
Character Encoding Default Character Encoding Data Matrix ECI Output Enabled Maxicode Maxicode Disabled Maximum Length 150 Minimum Length 1 Chinese Sensible Code Chinese Sensible Code Disabled Maximum Length 7827 Minimum Length 1 Chinese Sensible Twin Code Single Chinese Sensible Code Only Chinese Sensible Code Inverse Decode Regular Chinese Sensible Barcodes Only GM Code GM Disabled Maximum Length 2751 Minimum Length 1 Code One Code One Disabled DotCode DotCode Disabled Maximu
Specific OCR-B Specific OCR-B Disabled Chinese ID Card OCR Chinese ID Card OCR Disabled Passport OCR Passport OCR Disabled Japan Post Japan Post Disabled China Travel Permit OCR China Travel Permit OCR Disabled Data Formatter Data Formatter Disabled Non-Match Error Beep On Data Format Selection Format_0 Prefix & Suffix All Prefixes/Suffixes Disabled Prefix Sequence Code ID+ Custom +AIM ID Custom Prefix Disabled AIM ID Prefix Disabled Code ID Prefix Disabled Custom Suffix Disabled
AIM ID Table Symbology AIM ID Possible AIM ID Modifiers (m) Code128 ]C0 GS1-128 (UCC/EAN-128) ]C1 EAN-8 ]E4 EAN-8 with Addon ]E3 EAN-13 ]E0 EAN-13 with Addon ]E3 UPC-E ]E0 UPC-E with Addon ]E3 UPC-A ]E0 UPC-A with Addon ]E3 Interleaved 2 of 5, ]Im 0, 1, 3 ITF-14 ]Im 1, 3 ITF-6 ]Im 1, 3 Matrix 2 of 5 ]X0 Code 39, Code 32 ]Am 0, 1, 3, 4, 5, 7 Codabar ]Fm 0, 2, 4 Code 93 ]G0 China Post 25 ]X0 AIM 128 ]C2 ISBT 128 ]C4 ISSN ]X0 ISBN ]X0 Industrial 25 ]S0 Stan
Symbology AIM ID Possible AIM ID Modifiers (m) PDF417 ]Lm 0-2 QR Code ]Qm 0-6 Aztec ]zm 0-9, A-C Data Matrix ]dm 0-6 Maxicode ]Um 0-3 Chinese Sensible Code ]X0 GM ]gm Micro PDF417 ]L0 Micro QR ]Q1 Code One ]X0 DotCode ]Jm USPS Postnet ]X0 USPS Inteligent Mail ]X0 Royal Mail ]X0 USPS Planet ]X0 KIX Post ]X0 Australian Postal ]X0 Japan Post ]X0 Specific OCR-B ]o2 Chinese ID Card OCR ]o2 Passport OCR ]o2 China Travel Permit OCR ]o2 (0~9) 0~5 Note: “m” repre
Code ID Table Symbology Code ID Code128 j GS1-128 (UCC/EAN-128) j EAN-8 d EAN-13 d UPC-E c UPC-A c Interleaved 2 of 5, e ITF-14 e ITF-6 e Matrix 2 of 5 v Code 39, Code 32 b Codabar a Code 93 i China Post 25 X AIM 128 X ISBT 128 X ISSN g ISBN B Industrial 25 I Standard 25 f Plessey n Code 11 H MSI Plessey m GS1 Composite y GS1 Databar (RSS) R Code 49 X Code 16K X COOP 25 X PDF417 r QR Code s Aztec z Data Matrix u
Symbology Code ID MaxiCode x Chinese Sensible Code h GM Code x Micro PDF417 R Micro QR X Code One X DotCode X USPS Postnet P USPS Inteligent Mail M Royal Mail x USPS Planet L KIX Post K Australian Postal A Japan Post J Specific OCR-B S Chinese ID Card OCR S Passport OCR O China Travel Permit OCR S
Symbology ID Number Symbology ID Number Code 128 002 GS1-128 (UCC/EAN-128) 003 EAN-8 004 EAN-13 005 UPC-E 006 UPC-A 007 Interleaved 2 of 5, 008 ITF-14 009 ITF-6 010 Matrix 2 of 5 011 Code 39, Code 32 013 Codabar 015 Code 93 017 China Post 25 019 AIM 128 020 ISBT 128 021 COOP 25 022 ISSN 023 ISBN 024 Industrial 25 025 Standard 25 026 Plessey 027 Code11 028 MSI-Plessey 029 GS1 Composite 030 GS1 Databar (RSS) 031 PDF417 032 QR Code 033 Aztec 034 Data
Symbology ID Number GM Code 040 Micro PDF417 042 Micro QR 043 Code One 048 DotCode 050 Specific OCR-B 064 Chinese ID Card OCR 065 Passport OCR 066 China Travel Permit OCR 068 USPS Postnet 096 USPS Inteligent Mail 097 Royal Mail 098 USPS Planet 099 KIX Post 100 Australian Postal 101 Japan Post 102 Code 49 132 Code 16K 133
ASCII Table Hex Dec Char 00 0 NUL (Null char.
Hex Dec Char 1e 30 RS (Request to Send) 1f 31 US (Unit Separator) 20 32 SP (Space) 21 33 ! (Exclamation Mark) 22 34 " (Double Quote) 23 35 # (Number Sign) 24 36 $ (Dollar Sign) 25 37 % (Percent) 26 38 & (Ampersand) 27 39 ` (Single Quote) 28 40 ( (Left/ Opening Parenthesis) 29 41 ) (Right/ Closing Parenthesis) 2a 42 * (Asterisk) 2b 43 + (Plus) 2c 44 , (Comma) 2d 45 - (Minus/ Dash) 2e 46 .
Hex Dec Char 3e 62 > (Greater Than) 3f 63 ? (Question Mark) 40 64 @ (AT Symbol) 41 65 A 42 66 B 43 67 C 44 68 D 45 69 E 46 70 F 47 71 G 48 72 H 49 73 I 4a 74 J 4b 75 K 4c 76 L 4d 77 M 4e 78 N 4f 79 O 50 80 P 51 81 Q 52 82 R 53 83 S 54 84 T 55 85 U 56 86 V 57 87 W 58 88 X 59 89 Y 5a 90 Z 5b 91 [ (Left/ Opening Bracket) 5c 92 \ (Back Slash) 5d 93 ] (Right/ Closing Bracket)
Hex Dec Char 5e 94 ^ (Caret/ Circumflex) 5f 95 _ (Underscore) 60 96 ' (Grave Accent) 61 97 a 62 98 b 63 99 c 64 100 d 65 101 e 66 102 f 67 103 g 68 104 h 69 105 i 6a 106 j 6b 107 k 6c 108 l 6d 109 m 6e 110 n 6f 111 o 70 112 p 71 113 q 72 114 r 73 115 s 74 116 t 75 117 u 76 118 v 77 119 w 78 120 x 79 121 y 7a 122 z 7b 123 { (Left/ Opening Brace) 7c 124 | (Vertical Bar) 7d 125 } (Right/ Closing Brace) 7e 1
Unicode Key Maps 104 Key U.S.