NOTE: In the highly unlikely event that the
secondary fan does not keep the tempera-
ture below 85˚ C, the 600-HP automatically shuts
down until AC power is removed and reapplied. If
the 600-HP shuts down again after cooling and re-
applying AC power, contact Meyer Sound for repair
information.
Despite the 600-HP’s filtering, extensive use or a dusty op-
erating environment can allow dust to accumulate along the
path of the airflow, preventing normal cooling. To prevent
this, you should periodically remove the grille frame, air-in-
take foam and amplifier module and use compressed air to
clear dust from the grille, foam, fans, and heatsinks. Make
sure that the air ducts are clear.
CAUTION: Be sure to unplug power to the
unit before cleaning the amplifier.