Datasheet

HP 1200W Common Slot Silver Hot Plug Power Supply Kit
Part Number
500172-B21
Input Voltage Range ( V rms )
100 to 240
Frequency Range (Nominal) ( Hz )
50/60
Nominal Input Voltage ( Vrms )
100 120 200 208 220 230 240
Maximum Rated Output Wattage Rating
800 900 1200 1200 1200 1200 1200
Nominal Input Current ( A rms )
9.7 9.0 7.0 6.8 6.4 6.1 5.9
Maximum Rated Input Wattage Rating ( Watts )
930 1034 1348 1348 1348 1348 1348
Maximum Rated VA ( Volt-Amp )
970 1079 1406 1406 1406 1406 1406
Efficiency ( % )
86 86 89 89 89 89 89
Power Factor
0.97
Leakage Current ( mA )
0.42 0.50 0.83 0.87 0.92 0.96 1.00
Maximum Inrush Current ( A peak )
30
Maximum Inrush Current duration ( mS )
20
Maximum British Thermal Unit Rating ( BTU-Hr )
3174 3530 4600 4600 4600 4600 4600
HP 1200W Common Slot Platinum Hot Plug Power Supply Kit
Part Number
578322-B21
Input Voltage Range ( V rms )
100 to 240
Frequency Range (Nominal) ( Hz )
50/60
Nominal Input Voltage ( Vrms )
100 120 200 208 220 230 240
Maximum Rated Output Wattage Rating
800 900 1200 1200 1200 1200 1200
Nominal Input Current ( A rms )
9.3 8.6 6.7 6.5 6.1 5.8 5.6
Maximum Rated Input Wattage Rating ( Watts )
889 989 1290 1290 1290 1290 1290
Maximum Rated VA ( Volt-Amp )
927 1031 1345 1345 1345 1345 1345
Efficiency ( % )
90 91 93 93 93 93 93
Power Factor
0.97
Leakage Current ( mA )
0.42 0.50 0.83 0.87 0.92 0.96 1.00
Maximum Inrush Current ( A peak )
30
Maximum Inrush Current duration ( mS )
20
Maximum British Thermal Unit Rating ( BTU-Hr )
3033 3375 4403 4403 4403 4403 4403
NOTE:
To review typical system power ratings use the HP Power Advisor which is available online located at url:
www.hp.com/go/proliant-energy-efficient
or
www.hp.com/go/hppoweradvisor
QuickSpecs
HP ProLiant DL580 Generation 7 (G7)
Power Specifications
DA - 13669 Worldwide — Version 35 — September 24, 2012
Page 47