User guide

Troubleshooting
C4705-90000
8-39
  
 !%"! # $# $#$ # $ &"( $ !"$  $  ## "
" " $  $$ $#$ #   '#
 $ "& #$# #%% #"  $ )  $$  !"## 
SERVICE TESTS
18 Edge detect
 ) (# #  # " #  ## # #!( $
" $*!
# $   $  & $ "" $ $ $  $   $  & $
"" $ $ "$
If the value (###) of   is less than 100 when passing over the drive roller then
the line sensor has passed the test.
If the value (###) of   is more than 110 when passing over the media that is
loaded then the line sensor has passed the test.
If the values (###) of   is not within the above required ranges then the line
sensor has failed the test. To resolve the problem, try one of the following:
1 Clean the drive roller surface.
2 Perform the line sensor calibration page 7Ć5.
3 Perform the mainĆcarriage com test page 8Ć26.
4 Replace the carriage page 6Ć34.
"## $  %$$  ' $ $#$ #   !$