Owner manual

HP 8/20q Fibre Channel Switch QuickTools Switch Management User Guide 69
Modifying an SNMP v3 user
To modify an SNMP v3 user:
1. Select the entry switch in the fabric tree.
2. Select Switch > SNMP > SNMP v3 Manager to open the SNMP v3 Manager dialog box (Figure 32).
3. Select a user in the user list, and select Edit > Edit User to open the SNMP v3 User dialog box.
4. Modify the entries as needed, and click OK. For information about the entry fields, see Table 13.
5. Click OK to save the settings and close the SNMP v3 User Editor dialog box.
6. In the SNMP v3 Manager dialog box, click OK to save and activate the SNMP v3 security
configuration.
Removing an SNMP v3 user
To remove an SNMP v3 user:
1. Select the entry switch in the fabric tree.
2. Select Switch > SNMP > SNMP v3 Manager to open the SNMP v3 Manager dialog box (Figure 32).
3. Select a user in the user list, and select Edit > Remove User.
4. Click Yes to remove the user; click Cancel to cancel the removal.
5. Click OK to save the settings and close the SNMP v3 User Editor dialog box.
6. In the SNMP v3 Manager dialog box, click OK to save and activate the SNMP v3 security
configuration.
Testing a switch
The Switch Diagnostics dialog box (Figure 34) allows you to test and verify the operational status of
switches (online and offline). To open the Switch Diagnostic dialog box, open the Switch menu, select
Switch Diagnostics, and then select Online Switch Diagnostics or Offline Switch Diagnostics. For each type
of test, only one switch at a time can be tested. Offline Diagnostics can only be selected for the entry
switch.
Figure 34 Switch Diagnostics dialog box