Technical data

4-72 Fault Isolation
C. Switch the system unit power off and remove the power supply screws and
slide the power supply out about 3 inches. Switch the power on and mea
-
sure the voltages on the two power supply connectors as shown in
Figure 4-22 and Figure 4-23 (leave the connectors connected to the power
supply and measure the voltages through the rear of the connectors). If the
voltages are not present, go to Step D. If the voltages are present, go to
Step E.
D. Check Pin 24 on the large connector shown in Figure 4-22 for + 5 V dc. If
the voltage is not correct, replace the power supply.
If the voltage is correct at Pin 24, close the power-on switch. If you read
Pin 24 at ground, replace the power supply. If you still detect + 5 volts,
replace the power-on switch. If the new switch doesn’t fix the problem, go
to Step E.
E. Either the power distribution cable, motherboard, or CPU board are defec
-
tive. Check the power distribution cable for continuity. If the power distri
-
bution cable is defective, replace it. Otherwise, replace the CPU board and
recheck the voltage test points. If the voltages are not present, replace the
motherboard.
5. If the voltages are present at the CPU board or power supply test points but not
within tolerance, perform the following steps
A. Power off the system unit and unplug the ac power cord from the power
supply. Replace the power supply.
B. If the problem persists, reinstall the original power supply and follow the
information in this step to check for power loading by a board. Power off
the system unit and remove one board other than the CPU board. Power
on the system unit and retest. If necessary, repeat this procedure for a sec-
ond board. If you replace a defective board, configure any switches or
jumpers the same as the original board.
C. If a board does not appear to have caused the problem, power off the sys-
tem unit and unplug the power cord from the power supply. Reinstall the
boards in their slots.
D. Unplug the internal mass storage power distribution cable from one of the
mass storage devices. Power on the system unit and recheck the voltages.
If necessary, repeat this step for each internal mass storage device. Re-
place the mass storage device if the voltages are within specifications.
end of procedure