Command Reference Guide

Specifies that the current omnidbxp command is executed only for the LDEVs
pairs marked for the instant recovery in the XPDB. If this option is not specified,
the current command is executed for all LDEVs pairs in the XPDB.
-session -list
Lists all available sessions in the XPDB.
-session -show sessionID
Lists all backup system S-VOL LDEVs that were involved in the session with the
sessionID.
-ldev -list
Lists all S-VOL LDEVs in the XPDB together with their corresponding backup
sessionID.
-ldev -show SEQ LDEV
Lists all available XPDB information about the specified S-VOL LDEV. The following
information is listed: sessionID, CRC, IRflag, primary XP #, primary LDEV #,
primary port #, mirror type, MU#, date and time, application system and backup
system hostnames.
-cm -add serial {CU:LDEV | LDEV} hostname [instance]
Adds the command device identified by the serial number of the HP StorageWorks
Disk Array XP (serial) and serial number of command device in the
hexadecimal or decimal format (CU:LDEV or LDEV) to the XPDB, and assigns it
the hostname of the system accessing it (hostname) and optionally the instance
number (instance). If the instance number is not specified, Application Recovery
Manager assigns the lowest not yet assigned instance number.
The instance number must be any number in the range between 301 and 399.
The command does not check whether the specified command device or system
exist, it only checks if the optional instance number specified is within the correct
range and if the command device together with the instance number is not already
assigned to be used by some other system. If checks fail, the command fails with
an appropriate error message.
-cm -update serial {CU:LDEV | LDEV} hostname [instance]
Updates the XPDB information about the command device identified by the serial
number of the HP StorageWorks Disk Array XP (serial), serial number of
command device in the hexadecimal or decimal format (CU:LDEV or LDEV) and
the specified hostname of the system accessing it (hostname), by assigning the
newly specified instance number (instance) to the HP StorageWorks Disk Array
XP serial number, serial number of command device and hostname combination.
If the instance number is not specified, Application Recovery Manager assigns
the lowest not yet assigned instance number.
The instance number must be any number in the range between 301 and 399.
68