Brocade Fabric Watch Administrator's Guide Supporting Fabric OS v6.0.0 (53-1000601-01, October 2007)

Fabric Watch Administrator’s Guide 13
53-1000601-01
Configuring events
1
FIGURE 2 A buffered data region
Time bases
Time bases are time periods within Fabric Watch. This configurable field impacts the comparison of
sensor-based data with user-defined threshold values.
Setting time base to none
If you set a time base to none, Fabric Watch compares a data value against a threshold boundary
level. When the absolute value of the measuring counter exceeds the threshold boundary, an event
is triggered.
Figure 3 shows a high limit of 65 degrees Celsius placed on a counter measuring temperature.
During each sample period, Fabric Watch measures the temperature and compares it against the
high threshold. If the measured temperature exceeds the high threshold, it triggers an event.
FIGURE 3 Time base set to none
Specifying a time base
If you specify a time base value other than none (seconds, minute, hour, or day), Fabric Watch does
not use the current data value. Instead, it calculates the difference between the current data value
and the data value as it existed one time base ago. It compares this difference to the threshold
boundary limit.
For example, if you specify the time base minute, Fabric Watch calculates the counter value
difference between two samples a minute apart. It then compares the difference (current data
value – data value one minute ago) against the preset threshold boundary.