Brocade Fabric Watch Administrator's Guide Supporting Fabric OS v6.0.0 (53-1000601-01, October 2007)

74 Fabric Watch Administrator’s Guide
53-1000601-01
Port class
Table 26 provides default settings for areas in the F/FL_Port class.
Utilization (VE-port) Monitors utilization
of VE-ports by
percentage
Unit: Percentage(%)
Time Base: minute
Low: 0
High: 100
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Informative
Informative
Packet Loss
(VE-port)
Monitors total packet
loss by percentage
Unit: Percentage(%)
Time Base: minute
Low: 0
High: 100
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Informative
Informative
TABLE 26 F/FL_Port class threshold defaults
Area Description Default threshold settings Default alarm settings Threshold state
Loss of
Synchronization
Count
Monitors the
number of loss of
synchronization
errors
Unit: Error(s)
Time Base: minute
Low: 0
High: 5
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Receive Performance Monitors the
receive rate, by
percentage
Unit: Percentage(%)
Time Base: minute
Low: 0
High: 100
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Informative
Informative
Informative
State Changes Monitors state
changes
Unit: Change(s)
Time Base: minute
Low: 0
High: 5
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Transmit
Performance
Monitors the
transmit rate, by
percentage
Unit: Percentage(%)
Time Base: minute
Low: 0
High: 100
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Informative
Informative
Informative
Invalid CRC Count Monitors the
number of CRC
errors
Unit: Error(s)
Time Base: minute
Low: 0
High: 5
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Invalid Transmission
Word
Monitors the
number of invalid
words transmitted
Unit: Error(s)
Time Base: minute
Low: 0
High: 5
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Link Failure Count Monitors the
number of link
failures
Unit: Error(s)
Time Base: minute
Low: 0
High: 5
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
TABLE 25 E-Port class threshold defaults (Continued)