HP StorageWorks Fabric OS 5.3.0 Release Notes (AA-RWEYD-TE, July 2007)

Fabric OS 5.3.0
xes
Table 3 lists defects closed in the Fabric OS 5.3.0 rmware release.
Table 3 Fabric OS 5.3.0 closed defects
Closed defect su
mmary
Solution
4/256 Director running FICON with fsmode enabled & DLS on and
port based route policy panics after upgrade from Fabric OS 5.0.x to
5.1.x or 5.2.0.
Fixed per Fabric OS 5.3.0
Kernel Ops error when counter is overrun during stress to fail test.
Fixed per Fabric OS 5.3.0
Exception error on 4/256 can occur when performing port mirroring
causing reboot.
Fixed per Fabr
ic OS 5.3.0
Tstimezone command doesn’t show correct time and date if
configdownload interface is used to update timezone.
Fixed per Fabric OS 5.3.0
After executing trunk disable/enable on all edge switches in large
scalability fabric, a 2/128 E_port became stuck in Loopback mode.
Fixed per Fabric OS 5.3.0
Admin Domain
s enforcement on SID/DID not performed.
Portmirror a
llowed addition of mirror port in Admin Domain3
when SID and D
IDwerenotportmembers.
Fixed per Fabric OS 5.3.0
New active C P got Oops and reboot during initialization after
hafailover command issued.
Fixed per Fabric OS 5.3.0
After CP reboot, VE tunnel doesn’t come up due to GE0 port on
FR4-18i stuck in N o_Sync state when using copper SFP’s.
Fixed per Fabric OS 5.3.0
Switch does
n’t generate RSCN following zoning changes using
cfgEnable in interop mode, resulting in no PLOGI from hosts, and
no target discovery.
Fixed per Fabric OS 5.3.0
When more than the s upported number of EX-ports attached to same
edge fabric with FCR switches, switch may panic causing continuous
rebooting.
Fixed per Fabric OS 5.3.0
When more than the supported number of intelligent blad es (FR4-18i,
FC4-16IP, etc) conguredin4/256,poweringupthe4thand5th
blades at the same time results in a failover.
Fixed per Fabric OS 5.3.0
In rare occurrence, FR4-18i blade could become faulty after rmware
download and slotpoweron followed by slotpoweroff.
Fixed pe
r Fabric OS 5.3.0
Tape backup job failures occasionally observed in congested IO
conditions due to tape pipelining not properly handling target
recovery .
Fixed per Fabric OS 5.3.0
After changing FID & enabling FC R switch, all connected/active
ports remain disabled.
Fixed per Fabric OS 5.3.0
If active CP fails over after FC4-16ip port blade runs slotpower on,
all the FC4-16ip iSCSI ports can get stuck at No_Sync” while FC
ports come online.
Fixed p
er Fabric OS 5.3.0
After an all switches disable on 4/256 with FC4-48 port blades,
standby CP asserted and rebooted.
Fixed per Fabric OS 5.3.0
HAfailover during FCIP IO through IPSec enabled tunnel
sometimes causes VE port to go down, then come back up.
Fixed per Fabric OS 5.3.0
User w
as able to congure isns client via isnsccfg to communicate
with i
sns server through a port on FR4-18i, but this will not work (nor
shoul
dit).
Fixed in Fabric OS 5.3.0 to not
accept isnsccfg command for
FR4-18i port.
HP StorageW orks Fabric OS 5.3.0 release notes
17