HP StorageWorks Fabric OS 5.3.0 Release Notes (AA-RWEYD-TE, July 2007)
Modifying por t speed and trunking on FC4-48 ports from Web Tools,
followed by HAfailover, and then trying to re-launch, Port Admin
window on those same ports fails to reload Web Tools window.
Fixed per Fabric OS 5.3.0
F_Port route c
leanup doesn’t happen correctly when NPIV is used on
switch in Acce
ss Gateway mode.
Fixed per Fabr
ic OS 5.3.0
EZSwitch Setup device display is overlapped in Display Connection
window when window size not maximized.
Fixed per Fabric OS 5.3.0
Portstatsclear help page description of behavior on 2Gb and
4Gb platforms is ambiguous.
Fixed per Fabric OS 5.3.0
FR4-18i trac
edump files contain many BP error messages and one
empty file, potentially leading to incomplete support files.
Fixed per Fabric OS 5.3.0
During stress testing when rebooting all core switches in a loop,
E-ports may get stuck in “Mod_Val” mode.
Fixed per Fabric OS 5.3.0
Error messages are generated when applying iSCSI easycreate
operationfromWebToolsonunreachableFCTargets. Noerror
messages if LUN information is not retrievable from an FC Target.
Errors are only displayed when applying the operation.
Fixed per Fabric OS 5.3.0
If Dynamic Load Sharing (DLS) or In-Order Delivery is disabled, it
can’t be e
nabled from Web Tools. However, it can be set/reset via
CLI.
Fixed per
Fabric OS 5.3.0
Web Tools event filtering uses a time range of 0-11 rather than 1 -12.
In Web Tools Fabric Events and Events window, on invoking filter
button and filtering based on “from” time or “to” time, on providing a
time greater th an 12 (e.g. 12:30 PM) will result in an error stating
that time should be in range of 0-11.
Fixed per Fabric OS 5.3.0
Additional Port Info column in FC Ports tab in Web Tools shows
"None (FMS Mode)" instead of "Disabled (FMS Mode). "
Fixed per Fabric OS 5.3.0
FR4-18i blades rebooted during firmware commit process per
firmwaredownloadstatus output. Process does recover .
Fixed
per Fabric OS 5.3.0
With EZSwitchSetup, fixed zone can’t be configured with all
portsdesignatedasstorageorhosts. Thisiscorrectbehavior,
but the message displayed doesn’t describe how to corre ct the
misconfiguration should the user attempt to configure in that manner.
Fixed per Fabric OS 5.3.0
Error messages occur during IPsec FCIP IO. Fixed per Fabric OS 5.3.0
Incorrect information returned during Request Node Identification
Data (RNID) registration.
Fixe
d per Fabric OS 5.3.0
User sees wrong port type after port swap on issuing fwsamshow
from CLI, due to port t ype getting swapped in the SAM Report.
Fixed per Fabric OS 5.3.0
Due to current handling of invalid zone type during zone enforcement
after failover, Name Server daemon (nsd) panic results in CP fault
after firmwaredownload.
Fixed per Fabric OS 5.3.0
Unable to view policy details in the absence of IPSEC license from
“ShowIPSecuritypolicies”.
Fix
ed per Fabric OS 5.3.0
After changing an expired password and selecting another Admin
Domain during the same session, the password expiration message
and password prompt are displayed again. Currently have to exit
session and re-login after changing an expired password to avoid
this issue.
Fixed per Fabric OS 5.3.0
Error messages from ACL configuration through SMI are too generic
and don’t contain sufficient information to debug the problem.
Fixed per Fabric OS 5.3.0
20