HP StorageWorks Fabric OS 6.1.1 administrator guide (5697-0235, December 2009)

Fabric OS 6.1.x administrator guide 261
FC4-16IP Blade Configuration
This section describes the initial setup required to deploy an iSCSI gateway solution. Install and configure
the FC4-16IP blade in a 4/256 SAN Director as described in the FC4-16IP hardware reference manual
before performing these procedures.
NOTE: Only the 4/256 SAN Director with an iSCSI-enabled FC4-16IP blade running Fabric OS 5.2.0 or
later supports the iSCSI gateway service.
You can also configure an FC4-16IP blade through the Web Tools Graphical User Interface as an
alternative to the command line interface. See the Web Tools Administrator’s Guide for descriptions of
GUI-based configuration procedures.
FC4-16IP port numbering
The FC4-16IP blade integrates both GbE ports and FC ports. Ports are addressed using slot number and
port number notation, for example, 2/7. FC ports are numbered from 0 through 7; GbE ports are
numbered from ge0 through ge7.
NOTE: The FC4-16IP blade does not support FCIP functionality.
Figure 24 FC4-16IP ports
7
6
5
4
3
2
1
0
56-0000590-01 Rev A
!
FC4
16IP
ge7
ge6
ge5
ge4
ge3
ge2
ge1
ge0
GE
FC
scal e:
5/ 16" = 1"
ge7
ge0
GbE ports
FC ports
7
0
40. 1