HP StorageWorks Fabric OS 6.1.1 administrator guide (5697-0235, December 2009)

Fabric OS 6.1.x administrator guide 381
3. Issue the TA for ports 13 and 14 on slot 10 with a port index of 125:
switch:admin> porttrunkarea --enable 10/13-14 -index 125
Trunk index 125 enabled for ports 10/13 and 10/14.
4. Show the TA port configuration (ports still disabled):
switch:admin> porttrunkarea --show enabled
Slot Port Type State Master TI DI
-------------------------------------------
10 13 -- -- -- 125 125
10 14 -- -- -- 125 126
-------------------------------------------
5. Enable ports 13 aD 14:
switch:admin> portenable 10/13
switch:admin> portenable 10/14
6. Show the TA port configuration after enabling the ports:
switch:admin> porttrunkarea --show enabled
Slot Port Type State Master TI DI
-------------------------------------------
10 13 F-port Master 10/13 125 125
10 14 F-port Slave 10/13 125 126
Enabling F_Port trunking
The following procedure enables F_Port trunking on a stand-alone switch using ports 36-39.
1. Disable ports 36 - 39 by executing portDisable port for each port to be included in the TA.
2. Enable Trunk Area for ports 36 - 39 with area number 37:
switch:admin> porttrunkarea --enable 36-39 -area 37
Trunk area 37 enabled for ports 36, 37, 38 and 39.
3. Re-enable ports 36-39 by issuing portEnable port for each port in the TA.