User Manual
24 Performing basic configuration tasks
To set the time zone:
1. Connect to the switch and log in as admin.
2. Issue the tstimezone command as follows:
tstimezone [houroffset [, minuteoffset]]
• For Pacific Standard Time enter tsTimeZone -8,0
• For Central Standard Time enter tsTimeZone -6,0
• For Eastern Standard Time enter tsTimeZone -5,0
The default time zone for switches is Universal Time Conversion (UTC), which is 8 hours ahead of
(later than) Pacific Standard Time (PST). For additional time zone conversions, see Table 3.
The parameters do not apply if the time zone of the switch has already been changed from the default
(8 hours ahead of PST).
Refer to the tstimezone command in the HP StorageWorks Fabric OS 4.x command reference
guide for more detailed information about the command parameters.
3. Repeat the procedure on all switches for which the Time Zone needs to be set. This needs to be done
only once, because the value is written to nonvolatile memory.
For U.S. time zones, use Table 3 to determine the correct parameter for the tstimezone command.
Table 3 Conversion from UTC to local time
Local time tstimezone conversion
parameter
Atlantic Standard -4,0
Atlantic Daylight -3,0
Eastern Standard -5,0
Eastern Daylight -4,0
Central Standard -6,0
Central Daylight -5,0
Mountain Standard -7,0
Mountain Daylight -6,0
Pacific Standard -8,0
Pacific Daylight -7,0
Alaskan Standard -9,0
Alaskan Daylight -8,0
Hawaiian Standard -10,0