User Manual
92 Configuring the Core Switch 2/64 and the SAN Director 2/128
Setting chassis configurations
The chassisconfig command allows you to set the chassis configuration for products that support both
single-switch (one domain) and dual-switch (two domains) operation.
Table 13 lists the supported options for Fabric OS v4.4.0 or later. In the table, Blade ID 4 indicates a
SAN Director 2/128 card, and Blade ID 2 indicates a Core Switch 2/64 card.
The following sections contain procedures for obtaining chassis information, and for configuring director
domains using the chassisconfig command.
Obtaining slot information
For a Core Switch 2/64 or a SAN Director 2/128 configured as two logical switches, the chassis-wide
commands display or control both logical switches. In the default configuration, the SAN Director 2/128
is configured as one logical switch, so the chassis-wide commands display and control the single logical
switch.
To display the status of all slots in the chassis:
1. Connect to the switch and log in as user or admin.
2. Issue the slotshow command to display the current status of each slot in the system.
The format of the display includes a header and four fields for each slot. The fields and their possible
values are:
Table 13 Supported options
Option Result
1 One 128-port switch (Blade ID 4 on slots 1–4, 7–10)
2 Two 64-port switches (Blade ID 4 on slots 1–4, 7–10)
3 Two 64-port switches (Blade ID 4 on slots 1–4, ID 2 on slots 7–10)
4 Two 64-port switches (Blade ID 2 on slots 1–4, ID 4 on slots 7–10)
Table 14 Header fields
Field Value
Slot Displays the physical slot number.
Blade type Displays the card type:
• SW BLADE: The card is a switch.
• CP BLADE: The card is a control processor.
• UNKNOWN: The card is not present or its type is not recognized.