98 Configuring the Core Switch 2/64 and the SAN Director 2/128
15.Reissue the slotshow command until you see that POST diagnostics are finished and the status of all
cards is Enabled. For example:
slotshow
16.Issue the switchshow command to verify that port initialization is complete (no ports are shown as
Testing and all E_Ports, F_Ports, and L_Ports are Online).
17. Use the configdownload command to restore the configuration of sw0 (saved in step 2).
18.Manually configure sw1 as desired.
Setting the card beacon mode
When beaconing mode is enabled, the port LEDs flash amber in a running pattern from port 0 through
port 15 and back again. The pattern continues until you turn it off. This can be used to locate a particular
card.
To set the card beacon mode on:
1. Connect to the switch and log in as admin.
2. Issue the bladebeacon command with the following syntax at the command line:
bladebeacon slotnumber, mode
where slotnumber is the card where you want to enable beacon mode; this slot number must exist
on the logical switch. 1 turns beaconing mode on, or 0 turns beaconing mode off.
Example:
Slot Blade Type ID Status
1 SW BLADE 2 ENABLED
2 SW BLADE 2 ENABLED
3 SW BLADE 2 ENABLED
4 SW BLADE 2 ENABLED
5 CP BLADE 5 ENABLED
6 CP BLADE 5 ENABLED
7 SW BLADE 4 ENABLED
8 SW BLADE 4 ENABLED
9 SW BLADE 4 ENABLED
10 SW BLADE 4 ENABLED
switch:admin> bladebeacon 3, 1
switch:admin>