53-1001157-01 24 November 2008 Fabric OS Message Reference Supporting Fabric OS v6.2.
Copyright © 2007-2008 Brocade Communications Systems, Inc. All Rights Reserved. Brocade, Fabric OS, File Lifecycle Manager, MyView, and StorageX are registered trademarks and the Brocade B-wing symbol, DCX, and SAN Health are trademarks of Brocade Communications Systems, Inc., in the United States and/or in other countries. All other brands, products, or service names are or may be trademarks or service marks of, and are used to identify, products or services of their respective owners.
Title Publication number Summary of changes Date Fabric OS System Error Message Reference Manual 53-0000515-09 Updated for v4.4.
Title Publication number Summary of changes Date Fabric OS Message Reference 53-1000600-01 Updated for Fabric OS v6.0.0: -Added new chapters: C2, ESS, FICON -Added new messages to: AG, BL, BM, C2, FCIP, ISW, NS, PLAT, SS, HIL -Added Audit messages: SEC, SULB -Updated Introductory chapters. October 2007 Fabric OS Message Reference 53-1000600-02 Jun 2008 Updated for Fabric OS v6.1.
Contents About This Document In this chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xlvii How this document is organized . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xlvii Supported hardware and software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xlvii What’s new in this document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .xlviii Document conventions . . . . .
Responding to a System Message. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Looking Up a System Message . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Gathering Information About the Problem . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Panic Dump and Core Dump Files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AG-1026. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 AG-1027 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 AG-1028. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 AG-1029. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AUTH-1037. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 AUTH-1038 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 AUTH-1039 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 AUTH-1040 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 AUTH-1041. . . . . . . . .
BL-1025 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 BL-1026 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 BL-1027 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 BL-1028 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 BL-1029 . .
C2-1005. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 Chapter 9 CDR System Messages CDR-1001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 CDR-1002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 CDR-1003 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CNM-1021 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 CNM-1022 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 CNM-1023 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 CNM-1024 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 CNM-1025 . . . . . . . .
CVLC-1002. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95 CVLC-1003. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95 CVLC-1004. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 CVLC-1005. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 CVLC-1006. . . . . . . .
EM-1002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .105 EM-1003 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .105 EM-1004 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .106 EM-1005 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .106 EM-1006 . . . . . . . . . .
EM-1055 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117 EM-1056 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117 EM-1057 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117 EM-1058 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .118 EM-1059 . . . . . . . . .
FABR-1010. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .130 FABR-1011. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .130 FABR-1012. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .130 FABR-1013. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .131 FABR-1014. . . . . . . . . . . .
FABS-1006. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .142 FABS-1007 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .142 FABS-1008. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .143 FABS-1009. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .143 FABS-1010 . . . . . . . . . . .
FCR-1005. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .158 FCR-1006. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .158 FCR-1007. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .158 FCR-1008. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .158 FCR-1009. . . . . . . . . .
FCR-1048. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .168 FCR-1049. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .168 FCR-1053. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .169 FCR-1054. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .169 FCR-1055. . . . . . . . . .
FCR-1088. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .179 FCR-1089. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .179 Chapter 28 FICON System Messages FICN-1003 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .181 FICN-1004 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FICN-1036 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .190 FICN-1037 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .190 FICN-1038 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .191 FICN-1039 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .191 FICN-1040 . . . . . . . . .
FICN-1073 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .200 FICN-1074 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .201 FICN-1075 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .201 FICN-1076 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .201 FICN-1077 . . . . . . . . .
Chapter 32 FSPF System Messages FSPF-1001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .213 FSPF-1002. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .213 FSPF-1003. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .213 FSPF-1005. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FW-1033 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .224 FW-1034 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .224 FW-1035 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .225 FW-1036 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .225 FW-1037 . . . . . . . . . .
FW-1130 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .236 FW-1131 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .236 FW-1132 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .237 FW-1133 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .237 FW-1134 . . . . . . . . . .
FW-1186 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .248 FW-1187 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .248 FW-1188 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .248 FW-1189 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .248 FW-1190 . . . . . . . . . .
FW-1299 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .259 FW-1300 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .260 FW-1301 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .260 FW-1302 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .260 FW-1303 . . . . . . . . . .
FW-1336 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .272 FW-1337 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .272 FW-1338 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .272 FW-1339 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .273 FW-1340 . . . . . . . . . .
FW-1373 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .284 FW-1374. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .285 FW-1375 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .285 FW-1376 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .285 FW-1377 . . . . . . . . . .
Chapter 36 HAM System Messages HAM-1001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .297 HAM-1002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .297 HAM-1004 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .297 HAM-1005 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
HIL-1306 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .309 HIL-1307 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .309 HIL-1308 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .309 HIL-1309 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 310 HIL-1310 . . . . . . .
Chapter 42 IBD System Messages IBD-1001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .323 Chapter 43 IBPD System Messages IBPD-1001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .325 IBPD-1002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .325 IBPD-1003 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ISNS-1005 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .338 ISNS-1006 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .338 ISNS-1008 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .338 ISNS-1009 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .339 ISNS-1010 . . . . . . . . .
LOG-1001. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .349 LOG-1002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .349 LOG-1003 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .350 Chapter 54 LSDB System Messages LSDB-1001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Chapter 59 NBFS System Messages NBFS-1001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .365 NBFS-1002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .365 NBFS-1003 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .366 Chapter 60 NS System Messages NS-1001. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PDTR-1002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .377 Chapter 63 PLAT System Messages PLAT-1000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .379 PLAT-1001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .379 PLAT-1002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Chapter 68 RAS System Messages RAS-1001. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .391 RAS-1002. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .391 RAS-1004. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .391 RAS-1005. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Chapter 72 RTWR System Messages RTWR-1001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .403 RTWR-1002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .403 RTWR-1003 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .404 Chapter 73 SAS System Messages SAS-1001. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SEC-1042. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 417 SEC-1043. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 417 SEC-1044. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 417 SEC-1045. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 417 SEC-1046. . . . . . . .
SEC-1088. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .427 SEC-1089. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .427 SEC-1090. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .428 SEC-1091. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .428 SEC-1092. . . . . . . . . .
SEC-1136. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .437 SEC-1137. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .438 SEC-1138. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .438 SEC-1139. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .438 SEC-1142. . . . . . . . . .
SEC-1189. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .448 SEC-1190. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .449 SEC-1191. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .449 SEC-1192. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .449 SEC-1193. . . . . . . . . .
SEC-1319. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .459 SEC-1320. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .459 SEC-1321. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .459 SEC-1322. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .460 SEC-1323. . . . . . . . . .
SPC-2001. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .472 SPC-2002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .472 SPC-2003 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .472 SPC-2004 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .472 SPC-2005 . . . . . . . . . . .
SPM-1009 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .483 SPM-1010 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .483 Chapter 79 SS System Messages SS-1000. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .485 SS-1001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SULB-1037. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .500 Chapter 81 SWCH System Messages SWCH-1001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .501 SWCH-1002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .501 SWCH-1003 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TRCE-1004. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .512 TRCE-1005. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .512 TRCE-1006. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .512 TRCE-1007. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .513 TRCE-1008. . . . . . . . . . . .
WEBD-1002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .525 WEBD-1004 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .525 WEBD-1005 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .525 WEBD-1006 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .526 WEBD-1007 . . . . . . . . . . . . .
ZONE-1034 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .537 ZONE-1035 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .537 ZONE-1036 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .537 ZONE-1037 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .538 ZONE-1038 . . . . . . . . . . . . .
CONF-1020 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .551 CONF-1022 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .551 Chapter 92 AUDIT FCIP System Messages FCIP-1002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .553 FCIP-1003 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SEC-3012. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .568 SEC-3013. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .568 SEC-3014. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .569 SEC-3015. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .569 SEC-3016. . . . . . . . . .
SEC-3051. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .578 Chapter 99 AUDIT SNMP System Messages SNMP-1004 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .579 SNMP-1005 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .579 SNMP-1006 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
UCST-1024. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .596 UCST-1025. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .596 UCST-1026. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .596 UCST-1027. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
About This Document In this chapter • How this document is organized . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xlvii • Supported hardware and software. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xlvii • What’s new in this document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xlviii • Document conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xlix • Additional information . . . . . . . . . . . . .
• • • • • • • • • • • • • • Brocade 4018 switch Brocade 4020 switch Brocade 4024 switch Brocade 4100 switch Brocade 4900 switch Brocade 5000 switch Brocade 5100 switch Brocade 5300 switch Brocade 7500 Extension Switch Brocade 7500E Extension Switch Brocade 7600 switch Brocade 48000 director Brocade DCX Brocade Encryption Switch What’s new in this document The following changes have been made since this document was last released: • • • • • • • • • • • • • • • • • • • • xlviii Information that was modif
• “LFM System Messages” • “PMGR System Messages” • “TAPE System Messages” For further information about new features and documentation updates for this release, refer to the release notes. Document conventions This section describes text formatting conventions and important notice formats used in this document.
Notes, cautions, and warnings The following notices and statements are used in this manual. They are listed below in order of increasing severity of potential hazards. NOTE A note provides a tip, guidance or advice, emphasizes important information, or provides a reference to related information. ATTENTION An Attention statement indicates potential damage to hardware or data.
http://www.brocade.com Release notes are available on the Brocade Connect Web site and are also bundled with the Fabric OS firmware. Other industry resources For information about the Fibre Channel industry, visit the Fibre Channel Industry Association Web site: http://www.fibrechannel.org Getting technical help Contact your switch support supplier for hardware, firmware, and software support, including product repairs and part ordering. To expedite your call, have the following information available: 1.
• Brocade DCX-4S—On the bottom right on the port side of the chassis, directly above the cable management comb. 3. World Wide Name (WWN) Use the wwn command to display the switch WWN. • If you cannot use the wwn command because the switch is inoperable, you can get the WWN from the same place as the serial number, except for the Brocade DCX. For the Brocade DCX, access the numbers on the WWN cards by removing the Brocade logo plate at the top of the nonport side of the chassis.
Chapter Introduction To System Messages 1 In this chapter • Overview of System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 • Viewing and Configuring System Message Logs . . . . . . . . . . . . . . . . . . . . . . . 4 • Reading a RAS System Message . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 • Responding to a System Message . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 • System Module Descriptions . . . . . . . . .
1 Overview of System Messages • Trace dump, first-time failure detection capture (FFDC), and core dump files can be uploaded to the FTP server using the supportSave command. • It is recommended to configure the syslogd facility as a management tool for error logs. This is particularly important for dual-domain switches because the syslogd facility saves messages from two logical switches as a single file and in sequential order. See “System Logging Daemon (syslogd)” on page 3 for more information.
Overview of System Messages • • • • • • • • 1 FCIP-related messages: FCIP 1002 and 1003 FICU-related messages: FICU 1011 and 1012 FW-related messages: FW - 3001 HTTP configuration messages: HTTP-1002, 1003 IPAD-related messages: IPAD 1002 PORT related messages: PORT 1006 - 1009 SNMP-related messages: SNMP-1004 - 1006 Security-related messages (SFOS, RADIUS, login/logout, passwords, ACLs): SEC-3001 - 3041, 3044-3051 • Software upgrade library: SULB-1001 - 1004, 1009 - 1010, 1017 -1018, 1020 - 1021, 1023
1 Viewing and Configuring System Message Logs System Console The system console displays messages only through the serial port. If you log in to a switch through the Ethernet port or modem port, you will not receive system console messages. The system console displays system messages, Audit messages (if enabled) and panic dump messages. These messages are mirrored to the system console; they are always saved in one of the system logs.
Viewing and Configuring System Message Logs TABLE 2 1 Commands for Viewing or Configuring the System Parameters and Logs Command Description agtCfgDefault Resets the SNMP recipients to default values. agtCfgSet Modifies the SNMP agent configuration. agtCfgShow Displays the current SNMP agent configuration. auditCfg Configures the audit message log. auditShow Modifies and displays audit log filter configuration. diagPost Sets or displays diagnostic POST (Power-On Self-Test) configuration.
1 Viewing and Configuring System Message Logs TABLE 2 Commands for Viewing or Configuring the System Parameters and Logs (Continued) Command Description supportFfdc Enables and disables FFDC (first failure data capture). supportSave Collects RASLog, trace files, and supportShow (active CP only) information for the local CP and then transfers the files to an FTP server. The operation can take several minutes. supportShow Executes a list of diagnostic and error display commands.
Viewing and Configuring System Message Logs 1 2004/07/28-17:04:51, [EM-1055], 3,, WARNING, switch, Media 27: Port media incompatible. Reason: Configured port speed. 2004/07/28-17:04:54, [FABR-1001], 4,, WARNING, switch, port 4, ELP rejected by the other switch 2004/07/28-17:05:06, [FW-1050], 5,, WARNING, switch, Sfp Supply Voltage 0, is below low boundary(High=3600, Low=3150). Current value is 0 mV.
1 Reading a RAS System Message 2. Verify the configuration: switch:admin> auditcfg --show Audit filter is enabled. 1-ZONE 2-SECURITY 3-CONFIGURATION 4-FIRMWARE 5-FABRIC 3. Enable the audit feature: switch:admin> auditcfg --enable Audit filter is enabled. 4. Configure up to six syslog servers to receive the audit events that will be generated through syslog (procedure will vary depending on server type). 5. Configure syslog on the switch to point to the configured servers’ IP addresses.
Reading a RAS System Message TABLE 3 1 System Message Field Description (Continued) Example Variable Name Description 4 Sequence Number The error message position in the log. When a new message is added to the log, this number is incremented by 1. When this message reaches the last position in the error log and becomes the oldest message in the log, it is deleted when a new message is added.
1 Reading a RAS System Message AUDIT, 2005/12/10-09:54:03, [SEC-1000], WARNING, SECURITY, JohnSmith/root/192.168.132.10/Telnet/CLI, Domain A/JohnsSwitch, , Incorrect password during login attempt. The fields in the error message are described in Table 4. TABLE 4 10 Audit Message Field Description Example Variable Name Description AUDIT Audit flag Identifies the message as an Audit message.
Responding to a System Message 1 Message Severity Levels There are four levels of severity for messages, ranging from Critical (1) to Info (4). In general, the definitions are wide ranging and are to be used as general guidelines for troubleshooting. For all cases, you should look at each specific error message description thoroughly before taking action. System messages have the following severity levels.
1 Responding to a System Message Gathering Information About the Problem Common steps and questions to ask yourself when troubleshooting a system message are as follows: 1. What is the current Fabric OS level? 2. What is the switch hardware version? 3. Is the switch operational? 4. Assess impact and urgency: - Is the switch down? Is it a standalone switch? How large is the fabric? Is the fabric redundant? 5. Run the errDump command on each logical switch. 6.
System Module Descriptions 1 The software watchdog process (SWD) is responsible for monitoring daemons critical to the function of a healthy switch. The SWD holds a list of critical daemons that ping the SWD periodically at a predetermined interval defined for each daemon. The ping interval is set at 133 seconds, with the exception of the Fabric Watch daemon and the IP storage demon, which ping the SWD every 333 seconds. (For a complete listing of daemons, see the KSWD entry in Table 5.
1 System Module Descriptions TABLE 5 14 System Module Descriptions (Continued) System Module Description BL Blade error messages are a result of faulty hardware, transient out-of-memory conditions, application specific integrated circuit (ASIC) errors, or inconsistencies in the software state between a blade and the EM (environment monitor) module. BLL Bloom is the name of the application specific integrated circuit (ASIC) used as the building block for third-generation hardware platforms.
System Module Descriptions TABLE 5 1 System Module Descriptions (Continued) System Module Description FCPD The Fibre Channel Protocol daemon is responsible for probing the devices attached to the loop port. Probing is a process the switch uses to find the devices attached to the loop ports and to update the Name Server with the information. FCPH Fibre Channel Physical Layer is used to send Fibre Channel traffic to and from the switch.
1 System Module Descriptions TABLE 5 16 System Module Descriptions (Continued) System Module Description ICPD ICPD stands for iSCSI gateway daemon on a control processor (CP). It manages iSCSI configurations such as CHAP, VT/LUN, DD/DDSet and portal configurations, and statistics such as iSCSI session/connection information. Moreover, ICPD distributes iSCSI configurations not only switch wide, but also fabric wide. It keeps track iSCSI VT status and updates VT status to BP.
System Module Descriptions TABLE 5 1 System Module Descriptions (Continued) System Module Description KTRC Kernel RAS trace module. LFM LFM error messages indicate problems with the logical fabric manager module that is responsible for making a logical switch use XISLs. This involves creating and managing LISLs in a logical fabric. LOG RASLog subsystem. LSDB The link state database is a part of the FSPF protocol that maintains records on the status of port links.
1 System Module Descriptions TABLE 5 18 System Module Descriptions (Continued) System Module Description RCS The reliable commit service daemon generates log entries when it receives a request from the zoning, security, or management server for passing data messages to switches in the fabric. RCS then requests reliable transport write and read (RTWR) to deliver the message.
System Module Descriptions TABLE 5 1 System Module Descriptions (Continued) System Module Description TRCK The track change feature tracks the following events: Turning on or off the track change feature CONFIG_CHANGE LOGIN LOGOUT FAILED_LOGIN If any of these events occur, a message is sent to the system message log. Additionally, if the SNMP trap option is enabled, an SNMP trap is also sent.
1 20 System Module Descriptions Fabric OS Message Reference 53-1001157-01
Section RASLog Messages This section provides the RASLog messages, including: • AG System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 • AUTH System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 • BKSW System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 • BL System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
• FSS System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • FSSM System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • FW System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • HAM System Messages. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • HAMK System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
• RTWR System Messages. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • SAS System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • SCN System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • SEC System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • SNMP System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Chapter AG System Messages 2 AG-1001 Message , [AG-1001], ,, ERROR, , N_Port ID virtualization (NPIV) is not supported by fabric port connected to port . Probable Cause N_Port ID virtualization (NPIV) capability is not supported by the fabric port to which the Access Gateway is connected. Recommended Action • On switches running Fabric OS 6.
2 AG-1004 Severity WARNING AG-1004 Message , [AG-1004], ,, ERROR, , Invalid response to fabric login (FLOGI) request from the fabric for N_Port . Probable Cause Indicates the fabric sent an invalid response to the FLOGI Extended Link Service (ELS) for the specified N_Port. Recommended Action Check the configuration of the fabric switch.
AG-1008 Recommended Action Severity 2 Check the connectivity between the Access Gateway N_Port and the fabric switch port. WARNING AG-1008 Message , [AG-1008], ,, WARNING, , Invalid port login (PLOGI) response from the fabric on the N_Port . Probable Cause Indicates the fabric switch management server did not accept the N_Port Login (PLOGI) request sent by the Access Gateway.
2 AG-1011 AG-1011 Message , [AG-1011], ,, WARNING, , Sending FDISC failed on N_Port . Probable Cause Indicates there was a failure sending discover F_Port service parameter request from the Access Gateway to the fabric switch. Recommended Action Check the configuration of the fabric switch connected to the Access Gateway.
AG-1015 Severity 2 INFO AG-1015 Message , [AG-1015], ,, WARNING, , Unable to find online N_Ports to connect to the fabric. Probable Cause Indicates either no other N_Port is configured or all N_Ports are currently offline. Recommended Action Check whether or not any other N_Port is configured.
2 AG-1019 Recommended Action Severity Run switchShow to display the status of all ports in the system. Run portCfgShow to display a list of ports currently configured as N_Ports. Ensure that the host is connected to an F_port. ERROR AG-1019 Message , [AG-1019], ,, WARNING, , Unable to failover N_Port . No other N Port in port group: is online. Probable Cause Indicates that failover across port groups is not supported.
AG-1023 Probable Cause Indicates the specified F_Port is failing over to its preferred N_Port. Recommended Action Run ag --mapshow to display the updated F_Port-to-N_Port mapping. Severity 2 INFO AG-1023 Message , [AG-1023], ,, INFO, , F_Port mapped to offline N_Port is failed over to its preferred N_Port . Probable Cause Indicates the specified N_Port has failed to come online.
2 AG-1027 Probable Cause Indicates there are insufficient resources. Recommended Action Run configure CLI on AG switch and increase the number of allowed logins on this port. Severity If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider.
Chapter AUTH System Messages 3 AUTH-1001 Message , [AUTH-1001], ,, INFO, , has been successfully completed. Probable Cause Indicates that the secret database operation has been updated using the secAuthSecret command. The values for Operation type can be “set” or “remove”. Recommended Action No action is required.
3 AUTH-1004 AUTH-1004 Message , [AUTH-1004], ,, ERROR, , Failed to set type to . Probable Cause Indicates that the authUtil command has failed to set the authentication configuration value. The data type is either “authentication type”, “DH group type”, or “policy type”. Recommended Action Retry the authUtil command.
AUTH-1008 Recommended Action Severity 3 Run the authUtil command to make sure the local switch supports the specified protocols: Fibre channel authentication protocol (FCAP) or Diffie Hellman - challenge handshake authentication protocol (DH-CHAP). ERROR AUTH-1008 Message , [AUTH-1008], ,, ERROR, , No security license, operation failed. Probable Cause Indicates that the switch does not have a security license.
3 AUTH-1012 AUTH-1012 Message , [AUTH-1012], ,, WARNING, , Authentication is rejected: port explain reason . Probable Cause Indicates that an authentication is rejected because the remote entity does not support authentication. Recommended Action Make sure the entity at the other end of the link supports authentication.
AUTH-1017 3 Probable Cause This may relate to an internal failure. Recommended Action Copy the message, collect switch information using the supportShow command, and contact your switch service provider. Severity ERROR AUTH-1017 Message , [AUTH-1017], ,, ERROR, , Invalid value to start authentication request: port , operation code . Probable Cause Indicates an internal problem with the Secure Fabric OS.
3 AUTH-1022 If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity INFO AUTH-1022 Message , [AUTH-1022], ,, ERROR, , Failed to extract from payload: port . Probable Cause Indicates that the authentication process failed to extract a particular value from the receiving payload.
AUTH-1025 Severity 3 ERROR AUTH-1025 Message , [AUTH-1025], ,, ERROR, , Failed to get during : port . Probable Cause Indicates that the authentication process failed to get the expected information during the specified authentication phase. Recommended Action Usually this problem is transient. The authentication might fail.
3 AUTH-1028 Reinitialize authentication using the portDisable and portEnable commands or the switchDisable and switchEnable commands. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1028 Message Probable Cause , [AUTH-1028], ,, ERROR, , Failed to allocate for : port .
AUTH-1031 3 Probable Cause Indicates the receiving payload does not have valid message code for a particular authentication phase. Recommended Action Usually this problem is transient. The authentication might fail. Reinitialize authentication using the portDisable and portEnable commands or the switchDisable and switchEnable commands. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider.
3 AUTH-1034 Probable Cause Indicates that an entity was not configured in the switch connection control (SCC) policy and tried to connect to the port. Recommended Action Add the entity's world wide name (WWN) to the SCC policy and reinitialize authentication by using the portDisable and portEnable commands or the switchDisable and switchEnable commands.
AUTH-1037 3 If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1037 Message , [AUTH-1037], ,, ERROR, , Failed to response for : init_len , resp_len , port .
3 AUTH-1040 Recommended Action Severity Correct the switch policy configuration on either of the switches using the authUtil command, and then enable the port using the portEnable command. ERROR AUTH-1040 Message , [AUTH-1040], ,, INFO, , Reject authentication on port , because switch authentication policy is set to OFF. Probable Cause Indicates that the local switch has rejected the authentication because the switch policy is turned off.
AUTH-1043 Recommended Action 3 Check the connection port for a possible security attack. Check the shared secrets using secAuthSecret and reinitialize authentication using the portDisable and portEnable commands. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider.
3 46 AUTH-1044 Fabric OS Message Reference 53-1001157-01
Chapter BKSW System Messages 4 BKSW-1003 Message Probable Cause , [BKSW-1003], ,, WARNING, , kSWD: . Indicates a warning state within the system. A critical application error was reported in the watchdog subsystem. This message is used to convey information that might be of interest to you regarding the state of the system. Refer to the string at the end of the error message for specific information.
4 48 BKSW-1003 Fabric OS Message Reference 53-1001157-01
Chapter BL System Messages 5 BL-1000 Message , [BL-1000], ,, INFO, , Initializing ports... Probable Cause Indicates that the switch has started initializing the ports. Recommended Action No action is required. Severity INFO BL-1001 Message , [BL-1001], ,, INFO, , Port initialization completed. Probable Cause Indicates that the switch has completed initializing the ports.
5 BL-1003 Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. Additional blade fault messages precede and follow this error, providing more information. See other error messages for recommended action. If the message persists, replace the blade. Severity CRITICAL BL-1003 Message , [BL-1003], , FFDC, CRITICAL, , Faulting blade in slot . Probable Cause Indicates a faulty blade in the specified slot number.
BL-1007 5 Probable Cause Indicates that the errors (mostly synchronization errors) on this blade are harmless. Probably, the standby control processor (CP) blade connected to the active CP blade has experienced transitory problems. Recommended Action Use the haShow command to verify that the standby CP is healthy. If the standby CP was removed or faulted by user intervention, no action is required.
5 BL-1010 Recommended Action Make sure that the blade is seated correctly. If the blade is seated correctly, reboot or power cycle the blade. Run the systemVerification command to verify that the blade does not have hardware problems. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. Refer to the Fabric OS Command Reference for more information on these commands. If the message persists, replace the blade.
BL-1012 5 BL-1012 Message , [BL-1012], ,, ERROR, , bport port int. is disabled. status=0x Port will be re-enabled in 1 minute. Probable Cause Indicates that the port generated an excessive number of interrupts that might prove unrecoverable to the switch operation. The port is disabled to prevent the control processor (CP) from becoming too busy.
5 BL-1015 Recommended Action Make sure to capture the console output during this process. On a bladed switch, run the slotPowerOff and slotPowerOn commands. On a nonbladed switch, reboot the switch. Run the systemVerification command to determine if there is a hardware error. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled.
BL-1017 Recommended Action 5 Make sure that the blade is seated correctly. If the blade is seated correctly, reboot or power cycle the blade. Run the systemVerification command to verify that the blade does not have hardware problems. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. Refer to the Fabric OS Command Reference for more information on these commands. If the message persists, replace the blade.
5 BL-1020 BL-1020 Message , [BL-1020], ,, CRITICAL, , Switch timed out initializing the chips. Probable Cause Indicates that the switch has failed to initialize the application-specific integrated circuit (ASIC) chips. Recommended Action Reboot or power cycle the switch. Run the systemVerification command to verify that the switch does not have hardware problems. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled.
BL-1023 5 BL-1023 Message , [BL-1023], ,, CRITICAL, , Blade in slot was reset before blade init completed. As a result the blade is faulted. Probable Cause Indicates that the blade was reset before the initialization completed. Recommended Action Reboot or power cycle the blade. Severity If the message persists, replace the blade.
5 BL-1027 Recommended Action Severity Collect supportSave information, then reboot switch and run the diagPost command to ensure Power-On Self-Test (POST) is enabled. If problem persists, replace switch. CRITICAL BL-1027 Message , [BL-1027], ,, CRITICAL, , Blade in slot faulted, boot failed; status 0x 0x<1250 0 boot status> 0x<1250 1 boot status>. Probable Cause Indicates that the blade failed to boot properly.
BL-1030 5 BL-1030 Message , [BL-1030], ,, INFO, , All GigE/FCIP Virtualization/FC Fastwrite ports on the switch will be reset as part of the firmware upgrade. Probable Cause Indicates that a recent firmware upgrade caused the switch's internal processor firmware to be upgraded and resulted in the cold upgrade. As part of the upgrade, all the GigE/Fibre Channel over IP (FCIP)/Virtualization data elements / FC Fastwrite ports were reset.
5 BL-1034 Probable Cause Indicates that the system timed out while waiting for disable messages from the user ports after disabling the ports. Recommended Action Reboot or power cycle the blade. Run the systemVerification command to verify that the blade does not have hardware problems. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. If the message persists, replace the blade. Refer to the Fabric OS Command Reference for more information on the systemVerification command.
BL-1037 5 BL-1037 Message , [BL-1037], ,, CRITICAL, , Faulting chip in slot = , miniS = ,port = due to BE/BI port fault. Probable Cause Fault the chip and disable all the ports on that chip. Recommended Action No action is required.
5 62 BL-1037 Fabric OS Message Reference 53-1001157-01
Chapter BLL System Messages 6 BLL-1000 Message Probable Cause , [BLL-1000], , FFDC, CRITICAL, , ASIC driver detected Slot port as faulty (reason: ) Indicates a blade regulation problem was reported on the specified slot number. The blade is faulted.
6 BLL-1000 If the message persists, replace the blade.
Chapter BM System Messages 7 BM-1001 Message Probable Cause , [BM-1001], ,, ERROR, , BM protocol version in slot . Indicates the firmware running on the control processor (CP) cannot communicate with the application processor (AP) blade in the indicated slot and determine the AP blade's firmware version. • • Recommended Action Severity The CP blade is running a later version than the AP blade.
7 BM-1004 Recommended Action Severity Use the slotPowerOff and slotPowerOn commands or reseat the affected blade. WARNING BM-1004 Message Probable Cause Recommended Action Severity , [BM-1004], ,, INFO, , Blade firmware on slot is not consistent with system firmware . Auto-leveling blade firmware to match system firmware.
BM-1007 7 BM-1007 Message , [BM-1007], ,, INFO, , Clearing EX/VEX/FC port configuration for all ports for blade in slot . Probable Cause Indicates the specified blade was detected for the first time after an FR4-18i was previously configured in the same slot. The new blade requires the specified port configurations to be cleared. The blade ports are cleared automatically. Recommended Action No action is required.
7 BM-1053 Recommended Action Severity The blade ports are cleared automatically. No action is required. INFO BM-1053 Message , [BM-1053], ,, WARNING, , Failed to establish connection between CP and Application Processor. Faulting switch. Probable Cause Indicates the control processor (CP) could not establish a connection to the application processor to communicate.
BM-1056 7 BM-1056 Message Probable Cause , [BM-1056], ,, INFO, , AP is not configured. Persistently disabling all ports on the switch. Indicates the policy of the specified switch is to persistently disable all ports the first time the AP is detected. This may be caused by one of the following: • The AP was detected for the first time on this switch. • The switch was configured under a different mode.
7 70 BM-1058 Fabric OS Message Reference 53-1001157-01
Chapter C2 System Messages 8 C2-1001 Message , [C2-1001], ,, ERROR, , Port port fault (the configured speed may not be supported by the SFP). Please change the SFP or check the cable. Probable Cause Indicates a deteriorated SFP, an incompatible SFP pair, or a faulty cable between the peer ports. Recommended Action Verify that you are using compatible SFPs on the peer ports.
8 C2-1005 C2-1005 Message , [C2-1005], ,, ERROR, , Rate limit configuration is not effective on S() user port because QoS license is not present. Probable Cause Indicates that the switch does not have the QoS license added. Rate Limit is a licensed feature and requires QoS license. Recommended Action Add QoS license to the switch to enable the Rate Limit functionality.
Chapter CDR System Messages 9 CDR-1001 Message , [CDR-1001], ,, ERROR, , Port port fault. Please change the SFP or check cable Probable Cause Indicates a deteriorated small form-factor pluggable (SFP), an incompatible SFP pair, a faulty cable between peer ports, or the port speed configuration does not match the capability of the SFP. Recommended Action Verify that you are using compatible SFPs on the peer ports.
9 CDR-1004 Severity CRITICAL CDR-1004 Message , [CDR-1004], , FFDC, ERROR, , , : invalid DMA ch pointer, chan:, good_addr:0x, bad_addr:0x. Probable Cause Indicates an internal error in the application specific integrated circuit (ASIC) hardware that may degrade data traffic. Recommended Action Whenever this error occurs, reboot the system at the next maintenance window.
Chapter CER System Messages 10 CER-1001 Message , [CER-1001], ,, ERROR, , HA Sync broken, since standby Advanced Performance Tuning module does not support FICON Management Server (FMS). Probable Cause Indicates that the high-availability (HA) synchronization between the active and standby control processors (CPs) is broken, because there is downlevel firmware loaded on the standby CP.
10 76 CER-1001 Fabric OS Message Reference 53-1001157-01
Chapter CHASSIS System Messages 11 CHASSIS-1002 Message , [CHASSIS-1002], ,, ERROR, , ki_gd_register_action failed with rc =. Probable Cause Indicates an internal error. Recommended Action For a bladed system, run the slotPowerOff command and slotPowerOn command on the blade to recover the system. For a non-bladed system, run the fastBoot command on the switch to recover the system.
11 CHASSIS-1005 CHASSIS-1005 Message , [CHASSIS-1005], ,, ERROR, , Diag attach failed during recovery, disabling slot = . Probable Cause Indicates that the Diag blade attach has failed during failover or recovery. Recommended Action On a Brocade 24000 or 48000 switch, run the slotPowerOff command followed by the slotPowerOn command.
Chapter CNM System Messages 12 CNM-1001 Message , [CNM-1001], ,, ERROR, , Failed to allocate memory: . Probable Cause Indicates that the specified function failed to allocate memory. Recommended Action Check memory usage on the switch using the memShow command. Reboot or power cycle the switch. Severity ERROR CNM-1002 Message , [CNM-1002], ,, ERROR, , Failed to initialize rc = .
12 CNM-1005 Probable Cause Indicates that the Crypto service is enabled or disabled on the switch. Recommended Action No action is required. Severity INFO CNM-1005 Message , [CNM-1005], ,, INFO, , Posting event CNM_EVT_GRP_LEADER_ELECTED Name [], WWN []. Probable Cause Indicates that the cluster encryption group leader is elected. Recommended Action No action is required.
CNM-1009 Recommended Action Severity 12 No action is required. INFO CNM-1009 Message , [CNM-1009], ,, INFO, , Posting event CNM_EVT_STANDALONE_MODE. Probable Cause Indicates that the node is in standalone mode. Recommended Action No action is required. Severity INFO CNM-1010 Message , [CNM-1010], ,, INFO, , Posting event CNM_EVT_CLUSTER_UDATA_UPDATE cid [], ulen [].
12 CNM-1013 Recommended Action Severity No action is required. INFO CNM-1013 Message , [CNM-1013], ,, INFO, ,Posting event GL Node Split condition, isolating peer GL node . Probable Cause Indicates that the encryption group (EG) is split. Recommended Action No action is required.
CNM-1017 Recommended Action Severity 12 No action is required. INFO CNM-1017 Message , [CNM-1017], ,, INFO, ,Got JOIN REQUEST from un-recognized GL node [], configured GL node is []. Probable Cause Indicates a join request was received from an invalid group leader (GL) node. Recommended Action No action is required.
12 CNM-1021 Probable Cause Indicates Node Admission Control failed. Recommended Action No action is required. Severity INFO CNM-1021 Message , [CNM-1021], ,, INFO, , Failed to sign the node authentication message, admission control might fail. Probable Cause Indicates Node Admission Control failed. Recommended Action No action is required.
CNM-1025 Probable Cause Indicates an operation is not required on a group leader (GL) node. Recommended Action No action is required. Severity 12 INFO CNM-1025 Message , [CNM-1025], ,, INFO, , Operation not allowed, as member is active with the Cluster. Eject member node and retry. Probable Cause Indicates an operation is not allowed because a member node is active with the cluster. Recommended Action No action is required.
12 CNM-1029 Probable Cause Indicates that the certificate file for the node already exists. Recommended Action No action is required. Severity INFO CNM-1029 Message , [CNM-1029], ,, INFO, , Certfile content does not match the cert sent by GL. Probable Cause Indicates that the contents of the node's certificate file is different from the certificate file sent by the group leader (GL) node. Recommended Action No action is required.
CNM-1033 12 Probable Cause Indicates that there is a size mismatch between a node's certificate file and the certificate file received from the group leader. Recommended Action No action is required. Severity INFO CNM-1033 Message , [CNM-1033], ,, INFO, , Some of the defined nodes in the Encryption Group are not ONLINE. Encryption Group is in degraded state. Probable Cause Indicates that the cluster is in a degraded state.
12 CNM-1037 Probable Cause Indicates an event is being posted to indicate the cluster is in a converged state. Recommended Action No action is required. Severity INFO CNM-1037 Message , [CNM-1037], ,, INFO, , Split-Brain Arbitration lost!, minority GL Node, remote:local [:]. Probable Cause Indicates that split arbitration is lost. Recommended Action No action is required.
CNM-1041 Recommended Action Severity 12 No action is required. INFO CNM-1041 Message , [CNM-1041], ,, INFO, , Updating persistent Cluster DB, please avoid powering off the switch. Probable Cause Indicates the system is updating the persistent database. Recommended Action No action is required. Severity INFO CNM-1042 Message , [CNM-1042], ,, INFO, , Done, updating persistent Cluster DB.
12 CNM-1044 Recommended Action Severity 90 No action is required.
Chapter CONF System Messages 13 CONF-1000 Message , [CONF-1000], , AUDIT, INFO, , configDownload completed successfully. . Probable Cause Indicates that the configDownload operation was initiated and completed successfully. The statement that follows, message strings, is the description of the classes of configuration parameters that were downloaded.
13 CONF-1021 CONF-1021 Message , [CONF-1021], ,, INFO, , configUpload not permitted . Probable Cause Indicates a configUpload operation is not permitted. There are many possible causes. Recommended Action Check the error log, correct the error and rerun configupload.
Chapter CTAP System Messages 14 CTAP-1001 Message , [CTAP-1001], ,, INFO, , Key acquisition for . Probable Cause Indicates that a change in the tape pool database has triggered the key acquisition process for each pool. Recommended Action Do not start tape backup or restore operations involving tape pools until the process is complete.
14 94 CTAP-1001 Fabric OS Message Reference 53-1001157-01
Chapter CVLC System Messages 15 CVLC-1001 Message , [CVLC-1001], ,, INFO, , re-key , LUN SN: .\nContainer: , Initiator: , LUN ID: . Probable Cause Indicates the First time encryption, Key expired or Manual re-key operation is performed.
15 CVLC-1004 CVLC-1004 Message , [CVLC-1004], ,, INFO, , Forceful encryption LUN removal while re-key session is still active.\nContainer: , Initiator: , LUN ID: . Probable Cause Indicates that the encryption LUN was forcefully removed while a re-key session was still active. Recommended Action No action is required.
CVLC-1009 Severity 15 ERROR CVLC-1009 Message , [CVLC-1009], ,, ERROR, , Wrong device type: should be , found .\nContainer: , Initiator: , LUN ID: . Probable Cause Indicates that the wrong device type was found. Recommended Action No action is required.
15 CVLC-1013 Recommended Action Severity Use cryptocfg command to change the LUN's metadata mode. ERROR CVLC-1013 Message , [CVLC-1013], ,, ERROR, , Unable to retrieve key record from the key archive.\nContainer: , Initiator: , LUN ID: . Probable Cause Indicates that the encryption engine is unable to retrieve the key record base on the key ID found in the metadata.
CVLC-1016 15 CVLC-1016 Message , [CVLC-1016], ,, INFO, , LUN is out of read only mode. Reason: .\nContainer: , Initiator: , LUN ID: . Probable Cause Indicates that the LUN is set back to read/write. Recommended Action No action is required.
15 CVLC-1020 Severity ERROR CVLC-1020 Message , [CVLC-1020], ,, ERROR, , Metadata exists while LUN is clear text.\nContainer: , Initiator: , LUN ID: . Probable Cause Indicates that metadata exists on the LUN that is clear text. Recommended Action Use cryptocfg command to confirm the configuration.
Chapter CVLMSystem Messages 16 CVLM-1001 Message , [CVLM-1001], ,, ERROR, , Failed to allocate memory: (). Probable Cause Indicates that the specified function failed to allocate memory. Recommended Action • Check memory usage on the switch using the memShow command. • Reboot or power cycle the switch.
16 CVLM-1005 Probable Cause Indicates that encryption engine nodes in the cluster encryption group have different configurations. Recommended Action Synchronize the configuration in the cluster group using the cryptocfg --commit command. Refer to the Fabric OS Command Reference Manual for more information on this command. Severity WARNING CVLM-1005 Message , [CVLM-1005], ,, INFO, , Crypto service is on the switch.
CVLM-1009 Probable Cause Indicates that the member of HAC is not in the fabric. Recommended Action Check the ISL port connected to the fabric. Severity 16 WARNING CVLM-1009 Message , [CVLM-1009], ,, INFO, , The member ( ) of HAC () is in the fabric. Probable Cause Indicates that the member of HAC is in the fabric. Recommended Action No action is required.
16 CVLM-1012 Recommended Action Severity 104 No action is required.
Chapter EM System Messages 17 EM-1001 Message , [EM-1001], , FFDC, CRITICAL, , is over heating: Shutting down. Probable Cause Indicates that a field-replaceable unit (FRU) is shutting down due to overheating. This is typically due to a faulty fan but can also be caused by the switch environment. Recommended Action Verify that the location temperature is within the operational range of the switch.
17 EM-1004 Run the systemVerification command to verify that the switch does not have hardware problems. Refer to the Fabric OS Command Reference for more information on this command. On the Brocade 24000 and 48000, replace the specified FRU. For the Brocade 3900, replace the motherboard FRU. For the Brocade 200E, 3016, 3250, 3850, 4012, 4016, 4018, 4020, 4024, 4100, 4900, 5000, 7500, and AP7600, replace the switch.
EM-1006 17 EM-1006 Message , [EM-1006], , FFDC, CRITICAL, , has faulted. Sensors below minimum limits. Probable Cause Indicates that the sensors show the voltage is below minimum limits. The switch or specified blade is being shut down for environmental reasons; the voltage is too low. Recommended Action If this problem occurs on a blade, it usually indicates a hardware problem on the blade; replace the blade.
17 EM-1009 EM-1009 Message , [EM-1009], , FFDC, CRITICAL, , powered down unexpectedly. Probable Cause Indicates that the environmental monitor (EM) received an unexpected power-down notification from the specified field-replaceable unit (FRU). This might indicate a hardware malfunction in the FRU. Recommended Action Try reseating the FRU. If the message persists, replace the FRU.
EM-1013 17 Probable Cause Indicates that a switch blade or nonbladed switch failed to transition from one state to another. It is faulted. The specific failed target state is displayed in the message. There are serious internal Fabric OS configuration or hardware problems on the switch. Recommended Action On Brocade DCX, 24000 and 48000, try reseating the indicated field-replaceable unit (FRU). If the message persists, reboot or power cycle the switch.
17 EM-1016 Severity WARNING EM-1016 Message , [EM-1016], ,, WARNING, , Cold recovery failed (). Probable Cause Indicates that a problem was discovered when performing consistency checks during a cold boot. Recommended Action Monitor the switch. Severity If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider.
EM-1028 17 Probable Cause Indicates that the current chassisConfig option is not supported by the firmware on the standby control processor (CP). This is true even if the standby comes up and appears to be operational. High availability (HA) synchronization of the CPs will not be allowed. Recommended Action Either change the chassisConfig option to 1 with the chassisConfig command, or upgrade the firmware on the standby to the version running on the active CP.
17 EM-1033 Probable Cause Indicates that the environmental monitor (EM) has found a switch blade that is inserted, but the ejector switch is not closed. The blade in the specified slot is treated as not inserted. Recommended Action Close the ejector switch (raise the slider in most blades, or completely screw in the upper thumbscrew for the FC4-48 port blade) if the field-replaceable unit (FRU) is intended for use.
EM-1036 Probable Cause 17 Suggests that since both power supplies associated with one of the two main circuits are present but faulty, maybe the circuit's switch has been turned off, or the AC power source has been interrupted for that circuit. The Switch side value is either "left" or "right" designating which circuit switch, facing the cable side of the chassis. The Switch side value indicates: • left: controls the odd numbered power supply units.
17 EM-1041 EM-1041 Message , [EM-1041], ,, WARNING, , Sensor values for : . Probable Cause Indicates that sensors detected a warning condition. All significant sensors for the field-replaceable unit (FRU) are displayed; each contains a header.
EM-1045 Probable Cause Indicates that the specified field-replaceable unit (FRU) cannot be powered on because the associated logical switch is shut down. Recommended Action Run the switchStart command on the associated logical switch. Severity 17 WARNING EM-1045 Message , [EM-1045], ,, WARNING, , is being powered .
17 EM-1048 Probable Cause Indicates that the control processor (CP) is no longer faulted. This message usually follows EM-1033. The new standby CP is in the process of rebooting and has turned off the CP_ERR signal. Recommended Action No action is required.
EM-1051 17 EM-1051 Message , [EM-1051], ,, INFO, , : Inconsistency detected, FRU re-initialized. Probable Cause Indicates that an inconsistent state was found in the field-replaceable unit (FRU). This occurs if the state of the FRU was changing during a failover. The FRU is reinitialized and traffic might have been disrupted. Recommended Action No action is required.
17 EM-1058 Probable Cause Indicates the blade is being automatically reset because of known resetable transient errors such as an application-specific integrated circuit (ASIC) parity error. Recommended Action No action is required if the switch does not reach the reset threshold for the switch or blade. If the reset threshold is reached on the switch or blade, the switch or blade will be faulted and should be replaced.
EM-1061 Severity 17 WARNING EM-1061 Message , [EM-1061], ,, WARNING, , Synchronization halted. Remove all blades of type or upgrade your standby CP, then reboot or run haSyncStart. Probable Cause Indicates a blade in the system is not supported by the release on the standby control processor (CP). Recommended Action Remove all blades of this type or upgrade your standby CP.
17 EM-1065 Probable Cause Indicates the blade is being powered off because a hardware (HW) application specific integrated circuit (ASIC) ERROR was detected, and you have selected to power off the problem blade when such a condition occurred. Recommended Action Contact support.
EM-1068 17 EM-1068 Message , [EM-1068], ,, ERROR, , High Availability Service Management subsystem failed to respond. A required component is not operating. Probable Cause Indicates that the HA subsystem has not returned a response within four minutes of the request from the Environmental Manager. It usually indicates that some component has not started properly or has terminated.
17 EM-2003 Recommended Action On bladed systems, try reseating the specified FRU. On nonbladed switches, reboot or power cycle the switch. If the problem persists: • Run the systemverification command to verify that the switch does not have hardware problems. Refer to theFabric OS Reference Manual for more information on this command. • On bladed systems, replace the specified FRU; otherwise replace the switch.
Chapter ESS System Messages 18 ESS-1001 Message , [ESS-1001], ,, WARNING, , A few switches in the fabric do not support the Coordinated HotCode protocol. Probable Cause Indicates one or more switches in the fabric do not support the Coordinated HotCode protocol. Continuing with the firmware download may cause data traffic disruption.
18 ESS-1004 ESS-1004 Message , [ESS-1004], ,, WARNING, , The resume message is rejected by the domain . Probable Cause Indicates that during the Coordinated HotCode protocol, a switch in the fabric has rejected the resume message which prevented the protocol from completing. Any data traffic disruption observed during the firmware download may have been due to the rejected resume message. Recommended Action No action is required.
Chapter EVMD System Messages 19 EVMD-1001 Message , [EVMD-1001], ,, WARNING, , Event could not be sent to remote proxy. = Probable Cause Indicates the event could not be sent to remote proxy. This could happen if the remote proxy switch cannot be reached through in-band. The event could not be sent to the remote proxy because the remote proxy switch cannot be reached through in-band.
19 126 EVMD-1001 Fabric OS Message Reference 53-1001157-01
Chapter FABR System Messages 20 FABR-1001 Message , [FABR-1001], ,, WARNING, , port , . Probable Cause Indicates that the specified switch port is isolated because of a segmentation resulting from mismatched configuration parameters. Recommended Action Based on the segmentation reason displayed within the message, look for a possible mismatch of relevant configuration parameters in the switches at both ends of the link.
20 FABR-1004 Run the fabStateShow command on both the receiving and transmitting switches. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider.
FABR-1007 Recommended Action 20 In case of severe memory corruption, the system might recover by performing an automatic failover. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING FABR-1007 Message , [FABR-1007], ,, WARNING, , IU free error, caller: .
20 FABR-1010 Recommended Action Severity The fabric daemon will discard the EFP. The system will recover through the EFP retrial process. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. WARNING FABR-1010 Message , [FABR-1010], ,, WARNING, , .
FABR-1013 20 FABR-1013 Message , [FABR-1013], , FFDC, CRITICAL, , No Memory: pid= file=
20 FABR-1016 FABR-1016 Message , [FABR-1016], ,, WARNING, , ficonMode is enabled. Probable Cause Indicates that FICON mode is enabled on the switch through a user interface command. Recommended Action No action is required. Severity WARNING FABR-1017 Message , [FABR-1017], ,, WARNING, , ficonMode is disabled. Probable Cause Indicates that FICON mode is disabled on the switch through a user interface command.
FABR-1020 20 Probable Cause Indicates that this switch is a value-line switch and has exceeded the limited fabric size: that is, a specified limit to the number of domains. This limit is defined by your specific value-line license key. The fabric size has exceeded this specified limit, and the grace period counter has started. If the grace period is complete and the size of the fabric is still outside the specified limit, Web Tools is disabled.
20 FABR-1023 Probable Cause Indicates that the fabric size has exceeded the value-line limit, and the grace period counter has started. If the grace period is complete and the size of the fabric is still outside the specified limit, Web Tools is disabled. Recommended Action Bring the fabric size within the licensed limits. Either a full fabric license must be added or the size of the fabric must be changed to within the licensed limit. Contact your switch provider to obtain a full fabric license.
FABR-1030 20 • VC_RDY mode: Virtual-channel flow control mode. This is a proprietary protocol. • R_RDY mode: Receiver-ready flow control mode. This is the Fibre Channel standard protocol, that uses R_RDY primitive for flow control. • DUAL_CR mode: Dual-credit flow control mode. In both of the previous modes, the buffer credits are fixed, based on the port configuration information. In this mode, the buffer credits are negotiated as part of exchange link parameter (ELP) exchange.
20 FABR-1034 Severity WARNING FABR-1034 Message , [FABR-1034], , INFO, , Area have been acquired by port . Persistently disabling port . Probable Cause Indicates you must enable Trunk Area on a port for another port to use the same area. Recommended Action Move the cable to a port area that is not in use, or disable Trunk Area.
FABR-1038 20 Probable Cause Indicates the specified port is being disabled because when the port attempts to go online, the Switch finds that Trunk Area enabled is incompatible with port configuration such as long distance, port mirror, fast write or EX_port. Recommended Action Check the port configuration to disable long distance, port mirror, fast write or EX_port.
20 FABR-1041 FABR-1041 Message , [FABR-1041], , ERROR, , Port is disabled due to trunk protocol error. Probable Cause Indicates that a link reset was received before the completion of the trunking protocol on the port. Recommended Action Enable the port by running portEnable command. The port may recover by re-initialization of the link.
FABR-1046 Recommended Action Severity 20 Make sure that all the switches in the fabric have the same Base Switch attribute or disable VF mode for the conflicting switch using the fosconfig command. ERROR FABR-1046 Message , [FABR-1046], , ERROR, , Detected Base Switch conflict with neighbor switch (domain ), BS . E-ports () connected to the switch are disabled.
20 140 FABR-1046 Fabric OS Message Reference 53-1001157-01
Chapter FABS System Messages 21 FABS-1001 Message , [FABS-1001], , FFDC, CRITICAL, , Probable Cause Indicates that the system is low on memory and cannot allocate more memory for new operations. This is usually an internal Fabric OS problem or file corruption. Description of memory need indicates how much memory was being requested. The value could be any whole number.
21 FABS-1005 FABS-1005 Message Probable Cause , [FABS-1005], ,, WARNING, , (= ) Indicates that an unsupported operation has been requested. This is usually an internal Fabric OS problem or file corruption. The possible value for function name and description of problem is: fabsys_write: Unsupported write operation: process xxx where xxx is the process ID (PID), which could be any whole number.
FABS-1008 Severity 21 WARNING FABS-1008 Message , [FABS-1008], ,, WARNING, , : Media oid mapping failed Probable Cause Indicates that the Fabric OS was unable to locate a necessary object handle. This is usually an internal Fabric OS problem or file corruption. Recommended Action Reboot or power cycle the switch.
21 FABS-1012 Recommended Action Severity Reboot or power-cycle the CP or system. If the message persists, run the firmwareDownload command to update the firmware. ERROR FABS-1012 Message , [FABS-1012], ,, ERROR, , []:FRU state transition failed. Current state 0x Requested state 0x err 0x Probable Cause A FRU could not be transitioned to the requested state.
FABS-1015 Severity 21 ERROR FABS-1015 Message , [FABS-1015], ,, ERROR, , []:Request to enable FRU type 0x, unit failed. err code Probable Cause Indicates the specified FRU could not be enabled. This is usually an internal Fabric OS problem. Recommended Action Try removing and reinserting the FRU. Reboot or power-cycle the CP or system.
21 146 FABS-1015 Fabric OS Message Reference 53-1001157-01
Chapter FBC System Messages 22 FBC-1001 Message , [FBC-1001], ,, ERROR, , Firmware version on AP blade is incompatible with that on the CP. Probable Cause The CP determined that the version of firmware running on the AP blade is not compatible with the version of firmware running on the CP. The AP and CP blades cannot communicate. Recommended Action The problem can be corrected by changing the version of firmware on the CP or AP blades.
22 148 FBC-1001 Fabric OS Message Reference 53-1001157-01
Chapter FCIP System Messages 23 FCIP-1000 Message , [FCIP-1000], , FFDC, ERROR, , of GE failed. Please retry the command. Data: inst= st= rsn= fn= oid= Probable Cause Indicates that the hardware is not responding to a command request, possibly because it is busy. Recommended Action Retry the command.
23 FCIP-1004 Probable Cause Indicates that an IPsec/IKE policy was deleted and the config file was updated. Recommended Action No action is required. Severity INFO FCIP-1004 Message , [FCIP-1004], , INFO, CFG, , Tape Read Pipelining is being disabled slot () port () tunnel (). Probable Cause Indicates that the FOS version on the remote end of the tunnel does not support Tape Read Pipelining.
Chapter FCMC System Messages 24 FCMC-1001 Message , [FCMC-1001], , FFDC, CRITICAL, , System is low on memory and has failed to allocate new memory. Probable Cause Indicates that the switch is low on memory and failed to allocate new memory for an information unit (IU). Recommended Action A nonbladed switch will automatically reboot. For a bladed switch, the active CP blade will automatically fail over and the standby CP will become the active CP.
24 152 FCMC-1001 Fabric OS Message Reference 53-1001157-01
Chapter FCPD System Messages 25 FCPD-1001 Message Probable Cause , [FCPD-1001], ,, WARNING, , Probing failed on . Indicates that a Fibre Channel Protocol (FCP) switch probed devices on a loop port, and probing failed on the L_Port, or AL_PA address, or the F_Port. For the AL_PA, the valid range is 00 through FF.
25 154 FCPD-1003 Fabric OS Message Reference 53-1001157-01
Chapter FCPH System Messages 26 FCPH-1001 Message Probable Cause , [FCPH-1001], , FFDC, CRITICAL, , : failed, out of memory condition Indicates that the switch is low on memory and failed to allocate new memory for a Fibre Channel driver instance. The function can only be " fc_create". This function creates a Fibre Channel driver instance. The failed function call is "kmalloc_wrapper failed".
26 156 FCPH-1002 Fabric OS Message Reference 53-1001157-01
Chapter FCR System Messages 27 FCR-1001 Message , [FCR-1001], ,, INFO, , FC router proxy device in edge created at port . Probable Cause Indicates that a proxy device in the edge fabric has been imported at the specified port. Recommended Action No action is required. Severity INFO FCR-1002 Message , [FCR-1002], ,, INFO, , FC router proxy device in edge deleted at port .
27 FCR-1005 Recommended Action Severity Verify that the devices were intended to be taken offline. If not, verify that the devices are functioning properly. Verify that all small form-factor pluggables (SFPs) are seated correctly. Check for faulty cables, deteriorated SFPs, or dirty connections. Replace the cables and SFPs if necessary. INFO FCR-1005 Message , [FCR-1005], ,, INFO, , FC router LSAN zone device removed at port .
FCR-1009 27 Probable Cause Indicates that a logical storage area network (LSAN) zone was created at the specified port in the edge fabric. Recommended Action No action is required. Severity INFO FCR-1009 Message , [FCR-1009], ,, INFO, , FC router LSAN zone enabled at port : . Probable Cause Indicates that a logical storage area network (LSAN) zone was enabled in the edge fabric attached to the specified port.
27 FCR-1012 FCR-1012 Message , [FCR-1012], ,, INFO, , FC Router fabric build completed on port . Probable Cause Indicates that the fibre channel router has completed a fabric build at the specified port. Recommended Action No action is required. Severity INFO FCR-1013 Message , [FCR-1013], ,, INFO, , Phantom FSPF database exchange completed on port .
FCR-1018 27 FCR-1018 Message , [FCR-1018], ,, ERROR, , FC router proxy device entries exhausted on port . Probable Cause Indicates that the number of proxy devices is greater than allowed by the port resource. Recommended Action Remove excess logical storage area network (LSAN) zones or devices until the number of proxy devices exported is within the range allowed by the port resource.
27 FCR-1021 3. Use Zoning commands on the edge fabrics, to reduce the LSAN zone entries on the edge fabrics. 4. Run portEnable on each EX_Port, one at a time, to reenable the EX_Ports, and verify that this error is not reported again. Severity WARNING FCR-1021 Message , [FCR-1021], ,, WARNING, , Local LSAN device entries exhausted.
FCR-1024 27 FCR-1024 Message , [FCR-1024], ,, WARNING, , Local LSAN zone device entries for edge LSAN exhausted. Probable Cause Indicates that the number of devices in a logical storage area network (LSAN) defined in the edge fabric exceeds the local LSAN zone database limitations. Recommended Action Remove excess device entries from this LSAN zone until the number of devices is within the range of the local LSAN zone database limitations.
27 FCR-1028 Probable Cause Indicates that the port world wide name (WWN) pool has rolled over in the specified slot, and WWN entries detected to not be in use are reused as needed. Recommended Action It is unlikely that WWN conflicts will occur as a result of pool rollover unless the switch is deployed in a very large MetaSAN environment with large number of logical storage area network (LSAN) devices and fabrics, or there are highly dynamic changes to EX_Port connectivity.
FCR-1030 27 FCR-1030 Message , [FCR-1030], ,, INFO, , Physical device came online at fabric . Probable Cause Indicates that the physical device world wide name (WWN) came online in the specified fabric. Recommended Action No action is required. Severity INFO FCR-1031 Message , [FCR-1031], ,, INFO, , Physical device went offline in fabric .
27 FCR-1034 FCR-1034 Message , [FCR-1034], ,, INFO, , LSAN zone added in backbone fabric. Probable Cause Indicates that a new logical storage area network (LSAN) zone was added to the backbone fabric. Recommended Action No action is required. Severity INFO FCR-1035 Message , [FCR-1035], ,, INFO, , LSAN zone device added in the backbone fabric.
FCR-1038 27 FCR-1038 Message , [FCR-1038], ,, WARNING, , Total zone entries exceeded local fabric limits by entries, in zone: , zone limit: . Probable Cause Indicates that the number of cfg/zone/alias entries created in a local fabric is greater than the local switch's zone database limitations.
27 FCR-1042 Severity INFO FCR-1042 Message , [FCR-1042], ,, INFO, , LSAN zone removed in the backbone fabric. Probable Cause Indicates that a logical storage area network (LSAN) zone within the backbone fabric was removed. Recommended Action No action is required. Severity INFO FCR-1043 Message , [FCR-1043], ,, INFO, , Proxy device created in the backbone fabric.
FCR-1053 Recommended Action Severity 27 Run the portEnable and portDisable commands to enable and disable the port. If the problem persists contact your switch service provider. ERROR FCR-1053 Message , [FCR-1053], ,, WARNING, , Port was disabled, . Probable Cause Indicates that the specified port was disabled because of a mismatched configuration parameter.
27 FCR-1056 Severity INFO FCR-1056 Message , [FCR-1056], ,, INFO, , Switch with front domain ID does not support backbone to edge imports. Probable Cause Indicates that a switch that does not support backbone-to-edge routing is running in the MetaSAN. Recommended Action No action is required if backbone-to-edge routing is not needed. Otherwise replace the switch with one that supports backbone to edge routing.
FCR-1059 27 FCR-1059 Message , [FCR-1059], ,, INFO, , EX_Port was disabled due to an authentication failure. Probable Cause Indicates that the authentication, which uses the Diffie Hellman - challenge handshake authentication Protocol (DH-CHAP), failed on the EX_Port. Recommended Action Verify that the shared secrets on both sides of the link match.
27 FCR-1063 Probable Cause Indicates that the maximum number of supported EX_ports or VEX_ports was exceeded. To enable the specified port, disable any other operational port then re-enable the port. Recommended Action No action is required. Severity INFO FCR-1063 Message , [FCR-1063], ,, INFO, , Fabric for switch with domain ID: mismatch with local fabric ID .
FCR-1066 27 FCR-1066 Message , [FCR-1066], ,, ERROR, , Fabric on port has the same fabric ID as another fabric. Probable Cause Indicates that either the fabric split, or there is another fabric (possibly the backbone) that has the same fabric ID as the fabric connected to the specified port. Recommended Action If the fabric split, then merge the fabrics and manually re-enable the port.
27 FCR-1070 Probable Cause Indicates that the FC Routing service is enabled. This is caused by either fosConfig –-enable fcr, or a configDownload with the fcrState set to 1 (enabled). Note that the FC Routing service is disabled by the factory. Recommended Action No action is required. Severity INFO FCR-1070 Message , [FCR-1070], ,, INFO, , The FC Routing configuration is set to default.
FCR-1073 27 FCR-1073 Message , [FCR-1073], ,, INFO, , Switch with domain ID in fabric has lower limit of LSAN Zones supported. Probable Cause Indicates that a switch in the backbone/edge that supports different limit of logical storage area network (LSAN) zones was detected. Recommended Action Use the fcrResourceShow command on all Fibre Channel Routers in the Meta-SAN to find the lowest supported LSAN zone limits.
27 FCR-1076 FCR-1076 Message , [FCR-1076], ,, ERROR, , Port disabled, system only supports front domains. Probable Cause Indicates that the maximum number of supported front domains was exceeded. To enable the specified port, disable any other operational front domain and then re-enable the port. Recommended Action Make sure to remain within the maximum of supported front domains.
FCR-1080 Recommended Action Severity 27 Change the matrix database. WARNING FCR-1080 Message Probable Cause , [FCR-1080], ,, WARNING, , The pause response timer for domain expired. During the Coordinated HotCode protocol, a switch in the fabric has not responded to the pause message which prevented the protocol from completing. Any data traffic disruption observed during the firmware download may have been due to the rejected pause message.
27 FCR-1083 FCR-1083 Message , [FCR-1083], ,, WARNING, , The resume message is rejected by the domain . Probable Cause During the Coordinated HotCode protocol, a switch in the fabric has rejected the pause message which prevented the protocol from completing. Any data traffic disruption observed during the firmware download may have been due to the rejected resume message.
FCR-1087 Recommended Action Severity 27 Disable Condor2-based EX_ports or upgrade the remote CP. ERROR FCR-1087 Message , [FCR-1087], ,, ERROR, , ExPort connects to fabric with capability to use XISL domain . Probable Cause Indicates that the EX_Port connects to logical fabric containing a domain has the capability to use XISL. Recommended Action Disable Allow to use XISL mode of the domain by using the configure command.
27 180 FCR-1089 Fabric OS Message Reference 53-1001157-01
Chapter FICON System Messages 28 The FICON messages in this chapter include in many of the messages. The FICON Path is a string that includes, VEHDHPDDDPLPCUDV where: VE - VE Port Number: This number represents the FCIP Tunnel number through its VE Port number. HD - Host switch Domain number: This is a 1 byte hexidecimal value that represents the domain of the switch that the FICON Channel is directly connected to.
28 FICN-1005 FICN-1005 Message , [FICN-1005], ,, INFO, , FICON GEPort TID Feature Change verified Xrc <1 or 0 - XRC Emulation Enabled or Disabled> TapeWrt <1 or 0 - Tape Write Emulation Enabled or Disabled> TapeRd <1 or 0 - FICON Tape Read Emulation Enabled or Disabled> TinTir <1 or 0 - FICON TIN/TIR Emulation Enabled or Disabled> DvcAck <1 or 0 - FICON Device Level Ack Emulation Enabled or Disabled> RdBlkId <1 or 0 - FICON Write E
FICN-1008 28 FICN-1008 Message , [FICN-1008], ,, ERROR, , DevDiskEgr:FICON Purge Path received Path=. Probable Cause Indicates a FICON Purge Path was received from the channel as a part of path recovery. Recommended Action If there was a job failure associated with this event, please contact your vendor's customer support for assistance.
28 FICN-1012 Recommended Action Severity If there was an XRC volume or session suspended associated with this event, please contact your vendor's customer support for assistance. ERROR FICN-1012 Message , [FICN-1012], ,, ERROR, , DevDiskIng:Device level exception found for Path=: Oxid=0x. Probable Cause Indicates a Device Level Exception frame received from the FICON DASD Control Unit.
FICN-1015 28 FICN-1015 Message , [FICN-1015], ,, ERROR, , DevEgr:cuPath=:Discarding Invalid LRCd SOF=0x count=. Probable Cause Indicates a frame was received from the peer emulation processing with an invalid LRC. This indicates data corruption between the emulation processing components.
28 FICN-1019 FICN-1019 Message , [FICN-1019], ,, ERROR, , DevTapeEgr:AS Link Level Reject (LRJ) from Chan on Path= LastCmd=0x LastStatus=0x. Probable Cause Indicates the FICON channel indicated in the path issued an LRJ frame for a sequence from the device.
FICN-1023 28 Probable Cause Indicates the FICON channel issued a Selective Reset for a device that was active in emulation. Recommended Action If there was an unexpected job failure associated with this event, contact your vendor's customer support for assistance. Severity ERROR FICN-1023 Message , [FICN-1023], ,, ERROR, , DevTapeEgr:FICON Selective Reset:Path= Elapsed Time=.
28 FICN-1026 FICN-1026 Message , [FICN-1026], ,, INFO, , DevTapeIng:UnusualStatus:WriteCancelSelr:Generating Final Ending Status Path=. Probable Cause Indicates the FICON tape write pipeline is completing an emulated Selective Reset sequence. Recommended Action If there was an unexpected job failure or IO Error associated with this event, contact your vendor's customer support for assistance.
FICN-1030 Recommended Action Severity 28 If there was an unexpected job failure or IO Error associated with this event, contact your vendor's customer support for assistance. ERROR FICN-1030 Message , [FICN-1030], ,, ERROR, , HostDiskIng:FICON Purge received:Path=. Probable Cause Indicates an active disk emulation device received a FICON Purge Path from the channel.
28 FICN-1034 Recommended Action Severity No action is required. This is a part of the FICON path initialization. INFO FICN-1034 Message , [FICN-1034], ,, ERROR, , HostEgr:Discarding Invalid LRCd Frame on Path= count=. Probable Cause Indicates the channel emulation processing received a frame with an invalid FICON LRC from the peer.
FICN-1038 28 Probable Cause Indicates a locally connected FICON Channel issued an Establish Logical Path sequence to the specified FICON Control Unit. Recommended Action No action is required. This is a part of the FICON path activation. Severity INFO FICN-1038 Message , [FICN-1038], ,, ERROR, , fcFicIngHost:FDCB Lookup failed for Path=.
28 FICN-1041 FICN-1041 Message , [FICN-1041], ,, ERROR, , HostTapeEgr:AS Link Level Reject (LRJ) from CU Rx Path= LastCmd=0x LastStatus=0x. Probable Cause Indicates an LRJ received from a device indicates that the CU has lost the logical path to the LPAR.
FICN-1045 Recommended Action Severity 28 If this was an unexpected event, please contact your vendor's customer support for assistance. ERROR FICN-1045 Message , [FICN-1045], ,, WARNING, , HostTapeIng:FICON Purge received:Path=. Probable Cause Indicates a purge path was received from the locally connected FICON channel. This is performed during the path recovery.
28 FICN-1048 FICN-1048 Message , [FICN-1048], ,, WARNING, , DevDiskEgr:FICON Cancel received Path= state=0x sflags=0x. Probable Cause Indicates the operator has cancelled a read or write job. Recommended Action This is an unexpected event; contact your vendor's customer support for assistance.
FICN-1052 Recommended Action Severity 28 No action is required. This is a part of the XRC session establishment. INFO FICN-1052 Message , [FICN-1052], ,, INFO, , XRC Session Terminated: SessID=, Path=. Probable Cause Indicates a PSF command has been received to break an XRC session with the extended DASD device. Recommended Action If this was an unexpected event, contact your vendor's customer support for assistance.
28 FICN-1056 Probable Cause Indicates a suspend all devices from XRC session PSF command has been received to break an XRC session with the extended DASD device. Recommended Action If this was an unexpected event, contact your vendor's customer support for assistance.
FICN-1059 28 FICN-1059 Message , [FICN-1059], ,, ERROR, , Error return from frame generation for a FICON Image: Path=. Probable Cause Indicates an internal resource shortage caused an error such that an emulation frame could not be created and sent to an LPAR. Recommended Action This is an unexpected event, contact your vendor's customer support for assistance.
28 FICN-1063 Severity ERROR FICN-1063 Message , [FICN-1063], ,, ERROR, , Egress Abort:Oxid=0x:Path=:LastStates=0x. Probable Cause Indicates an abort operation has been received from a peer FC interface for an active emulation exchange. Recommended Action This is an unexpected event, contact your vendor's customer support for assistance.
FICN-1067 28 Probable Cause Indicates an internal resource limit has been encountered such that additional control block memory could not be allocated. Recommended Action This is an unexpected event, either the maximum number of emulation devices are already in use or there is an internal memory leak, contact your vendor's customer support for assistance.
28 FICN-1070 FICN-1070 Message , [FICN-1070], ,, INFO, , DevTapeIngr:Exceptional Status rcvd on Path= state=0x status=0x. Probable Cause Indicates the normal end of tape status (0x0D or 0x05) is received from the device or error status (including Unit Check 0x02) is received from an active emulation device.
FICN-1074 Recommended Action Severity 28 No action is required.
28 FICN-1077 Recommended Action Severity No action is required. INFO FICN-1077 Message , [FICN-1077], ,, INFO, , DevTapeEgr:Unloaded:Path=:states=0x<4 prior emulation states>:cmds=0x:status=0x:flags=0x.
FICN-1080 Recommended Action Severity 28 No action is required.
28 FICN-1083 FICN-1083 Message , [FICN-1083], ,, WARNING, , EmulEls:SW_RSCN received on GEPort= VEPort= Domain=0x Port=0x. Probable Cause Indicates an attached port with the established FICON emulated path has logged out from the switch. Recommended Action This may be an unexpected event, contact your vendor's customer support for assistance.
Chapter FICU System Messages 29 FICU-1001 Message , [FICU-1001], ,, ERROR, , : config failed rc = . Probable Cause Indicates that one of the configuration management functions failed. The key variable is part of the Fabric OS configuration database and is for support use only. The error variable is an internal error number.
29 FICU-1004 Severity WARNING FICU-1004 Message Probable Cause , [FICU-1004], ,, WARNING, , : Failed to set fabric manager server (FMS) mode: conflicting PID Format:, FMS Mode:. Indicates that a process ID (PID) format conflict was encountered. The core PID format is required for fibre connectivity control unit port (FICON-CUP).
FICU-1007 Recommended Action Severity 29 Check if the FICON channel corresponding to the PID in the message is functioning correctly. WARNING FICU-1007 Message , [FICU-1007], ,, WARNING, , : Failed to allocate memory while performing . Probable Cause Indicates that memory resources are low. This might be a transient problem. Recommended Action If the message persists, check the memory usage on the switch, using the memShow command.
29 FICU-1010 FICU-1010 Message , [FICU-1010], ,, WARNING, , FMS Mode enable failed due to address conflict with port . Probable Cause Indicates that the Fibre Connectivity (FICON) Management Server mode (fmsMode) was not enabled because the specified port which has an address conflict with the CUP management port is in use. Recommended Action Use the portDisable command to disable the specified port to avoid the port address conflict.
Chapter FKLB System Messages 30 FKLB-1001 Message , [FKLB-1001], ,, WARNING, , exchange overlapped, pid= Probable Cause Indicates that the FC kernel driver has timed out the exchange while the application is still active. When the FC kernel driver reuses the exchange, the application will overlap. This happens on a timed-out exchange; it automatically recovers after the application times the exchange out. Recommended Action No action is required.
30 210 FKLB-1001 Fabric OS Message Reference 53-1001157-01
Chapter FLOD System Messages 31 FLOD-1001 Message , [FLOD-1001], , FFDC, WARNING, , Unknown LSR type: port , type Probable Cause Indicates that the link state record (LSR) type is unknown. The following two LSR header types are the only known types: 1 - Unicast and 3 - Multicast. Recommended Action No action is required; the record is discarded.
31 FLOD-1006 Probable Cause Indicates that the received LSR contained an invalid domain number. Recommended Action No action is required; the LSR is discarded. Severity WARNING FLOD-1006 Message , [FLOD-1006], ,, WARNING, , Transmitting invalid domain ID: Probable Cause Indicates that the transmit LSR contained an invalid domain number. Recommended Action No action is required; the LSR is discarded.
Chapter FSPF System Messages 32 FSPF-1001 Message , [FSPF-1001], ,, ERROR, , Input Port out of range Probable Cause Indicates that the specified input port number is out of range; it does not exist on the switch. Recommended Action No action is required.
32 FSPF-1005 FSPF-1005 Message , [FSPF-1005], ,, ERROR, , Wrong Section Id , should be , input port = Probable Cause Indicates that an incorrect section ID was reported from the specified input port. The section ID is used to identify a set of switches that share an identical topology database. The section ID is implemented inside the protocol. The error message itself will indicate the mismatched section ID.
Chapter FSS System Messages 33 FSS-1001 Message , [FSS-1001], ,, WARNING, , Component () dropping HA data update (). Probable Cause Indicates that an application has dropped a high availability (HA) data update. Recommended Action Run the haSyncStart command if this is a dual-CP system, or reboot the switch if it is a nonbladed system.
33 FSS-1004 Severity WARNING FSS-1004 Message , [FSS-1004], ,, ERROR, , Memory shortage Probable Cause Indicates that the system ran out of memory. Recommended Action Run the memShow command to view memory usage. Run the haSyncStart command if this is a dual-CP system, or reboot the switch if it is a nonbladed system.
FSS-1008 33 Probable Cause Indicates that the Ethernet connection between the active control processor (CP) and standby CP is not healthy. The error occurs when the standby CP does not respond to a request from the active CP within five seconds. This usually indicates a problem with the internal Ethernet connection and a disruption of the synchronization process.
33 FSS-1011 FSS-1011 Message , [FSS-1011], ,, INFO, , FSS Info: . Probable Cause Indicates that an error has occurred. Recommended Action No action is required.
Chapter FSSM System Messages 34 FSSM-1002 Message , [FSSM-1002], ,, INFO, , HA State is in sync. Probable Cause Indicates that the high availability (HA) state for the active control processor (CP) is in synchronization with the HA state of the standby CP. If the standby CP is healthy, then a failover is nondisruptive. For more information on the haFailover command, refer to the Fabric OS Command Reference. Recommended Action No action is required.
34 FSSM-1004 Probable Cause Indicates that the active control processor (CP) and the standby CP in a dual CP system are running firmware that are incompatible with each other. If the active CP fails, the failover will be disruptive. In a switch system, this message is logged when a firmware upgrade/downgrade was invoked. The new firmware version is not compatiable with the current running version. This causes a disruptive firmware upgrade/downgrade.
Chapter FW System Messages 35 FW-1001 Message , [FW-1001], ,, INFO, ,
35 FW-1004 Severity WARNING FW-1004 Message , [FW-1004], ,, INFO, ,
FW-1007 35 FW-1007 Message , [FW-1007], ,, WARNING, ,
35 FW-1011 Recommended Action Severity Verify that you have installed the power supply correctly and that it is correctly seated in the chassis. If the problem persists, replace the faulty power supply. WARNING FW-1011 Message , [FW-1011], ,, INFO, ,
FW-1035 35 Probable Cause Indicates that the temperature of the small form-factor pluggable (SFP) has fallen below the low boundary. Recommended Action No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. Severity WARNING FW-1035 Message , [FW-1035], ,, WARNING, ,
35 FW-1038 Severity INFO FW-1038 Message , [FW-1038], ,, WARNING, ,
FW-1041 35 FW-1041 Message , [FW-1041], ,, INFO, ,
35 FW-1044 FW-1044 Message , [FW-1044], ,, INFO, ,
FW-1048 35 Probable Cause Indicates that the value of the small form-factor pluggable (SFP) voltage has risen above the high boundary. The supplied current of the SFP transceiver is outside of the normal range, indicating possible hardware failure. Recommended Action If the current rises above the high boundary, you must replace the SFP.
35 FW-1051 FW-1051 Message , [FW-1051], ,, WARNING, ,
FW-1115 35 Probable Cause Indicates that the number of times E_Ports have gone down has fallen below the low boundary. E_Ports go down each time you remove a cable or small form-factor pluggable (SFP). SFP failures also cause E_Ports to go down. E_Port downs might be caused by transient errors. A low number of E_Port failures means that the switch is functioning normally. Recommended Action No action is required.
35 FW-1118 • two fabrics have joined. • an E_Port has gone offline. • a principal link has segmented from the fabric. Recommended Action Severity Verify that the cable is properly connected at both ends. Verify that the small form-factor pluggables (SFPs) have not become faulty. An inexplicable fabric reconfiguration might be a transient error and might not require troubleshooting.
FW-1120 35 FW-1120 Message Probable Cause , [FW-1120], ,, INFO, ,
35 FW-1123 FW-1123 Message , [FW-1123], ,, INFO, ,
FW-1126 35 FW-1126 Message Probable Cause , [FW-1126], ,, INFO, ,
35 FW-1129 • • • • Recommended Action Severity Zone conflicts. Domain conflicts. Segmentation of the principal link between two switches. Incompatible link parameters. During E_Port initialization, ports exchange link parameters. Rarely, incompatible parameters result in segmentation. No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation.
FW-1132 Recommended Action Severity 35 No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. INFO FW-1132 Message , [FW-1132], ,, INFO, ,
35 FW-1135 FW-1135 Message , [FW-1135], ,, INFO, ,
FW-1139 35 Probable Cause Indicates that the number of small form-factor pluggable (SFP) state changes has fallen below the low boundary. SFP state changes occur when the SFP is inserted or removed. A low number of SFP state changes means that the switch is functioning normally. Recommended Action No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation.
35 FW-1161 Recommended Action Check both ends of your cable connection. Verify that the cable and small form-factor pluggables (SFPs) are not faulty. Losses of synchronization commonly causes link failures. If you receive concurrent loss of synchronization errors, troubleshoot the loss of synchronization. Severity INFO FW-1161 Message , [FW-1161], ,, INFO, , ,
FW-1164 35 Probable Cause Indicates that the number of link failures that the port experiences has changed from a value outside of the acceptable range to a value within the acceptable range. Link loss errors occur when a link experiences a loss of signal and fails. Both physical and hardware problems can cause link loss errors. Link loss errors frequently occur due to a loss of synchronization. Check for concurrent loss of synchronization errors and, if applicable, troubleshoot them.
35 FW-1167 Probable Cause Indicates that the number of synchronization losses that the port experiences has risen above the high boundary. Loss-of-synchronization errors frequently occur due to a faulty small form-factor pluggable (SFP) or cable. Signal losses often create synchronization losses. Recommended Action Check both ends of your cable connection. Verify that the cable and small form-factor pluggables (SFPs) are not faulty.
FW-1170 Recommended Action Severity 35 No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. A low number of signal loss errors means that the switch is functioning normally. INFO FW-1170 Message , [FW-1170], ,, WARNING, , ,
35 FW-1173 Severity INFO FW-1173 Message , [FW-1173], ,, INFO, , ,
FW-1176 35 FW-1176 Message , [FW-1176], ,, INFO, , ,
35 FW-1180 Probable Cause Indicates that the number of invalid words that the port experiences has changed from a value outside of the acceptable range to a value within the acceptable range. Invalid words usually indicate a hardware problem with an small form-factor pluggable (SFP) or cable. Recommended Action No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation.
FW-1183 Recommended Action Severity 35 This error generally indicates an deteriorating fabric hardware. Check your small form-factor pluggables (SFPs), cables, and connections for faulty hardware. Verify that all optical hardware is clean. WARNING FW-1183 Message , [FW-1183], ,, INFO, , ,
35 FW-1186 FW-1186 Message , [FW-1186], ,, INFO, , ,
FW-1190 Recommended Action Severity 35 No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. INFO FW-1190 Message , [FW-1190], ,, INFO, , ,
35 FW-1193 FW-1193 Message Probable Cause , [FW-1193], ,, INFO, , ,
FW-1196 35 FW-1196 Message , [FW-1196], ,, INFO, , ,
35 FW-1216 Probable Cause Indicates that the number of link resets that the port experiences has changed from a value outside of the acceptable range to a value within the acceptable range. Link resets occur due to link timeout errors that indicate no frame activity at all. Both physical and hardware problems can cause link resets to increase. Recommended Action Respond to this message as is appropriate to the particular policy of the end-user installation.
FW-1218 35 FW-1218 Message , [FW-1218], ,, WARNING, ,
35 FW-1241 Severity INFO FW-1241 Message , [FW-1241], ,, INFO, ,
FW-1244 Recommended Action Severity 35 No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. INFO FW-1244 Message , [FW-1244], ,, INFO, ,
35 FW-1247 FW-1247 Message , [FW-1247], ,, INFO, ,
FW-1251 35 Probable Cause Indicates that the number of end-to-end (EE) word frames that the switch transmits has risen above the high boundary. Transmit performance messages appear due to the number of word frames that travel from the configured S_ID to the D_ID pair. Recommended Action No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation.
35 FW-1274 Recommended Action Severity No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. INFO FW-1274 Message , [FW-1274], ,, INFO, ,
FW-1297 Severity 35 INFO FW-1297 Message , [FW-1297], ,, INFO, ,
35 FW-1300 Severity INFO FW-1300 Message , [FW-1300], ,, INFO, ,
FW-1303 35 FW-1303 Message , [FW-1303], ,, INFO, ,
35 FW-1306 FW-1306 Message , [FW-1306], ,, WARNING, ,
FW-1309 35 FW-1309 Message , [FW-1309], ,, INFO, ,
35 FW-1312 FW-1312 Message , [FW-1312], ,, INFO, ,
FW-1315 35 FW-1315 Message , [FW-1315], ,, INFO, ,
35 FW-1318 FW-1318 Message , [FW-1318], ,, WARNING, ,
FW-1321 35 FW-1321 Message , [FW-1321], ,, INFO, ,
35 FW-1324 FW-1324 Message , [FW-1324], ,, INFO, ,
FW-1327 35 FW-1327 Message , [FW-1327], ,, INFO, ,
35 FW-1330 FW-1330 Message , [FW-1330], ,, WARNING, ,
FW-1333 35 FW-1333 Message , [FW-1333], ,, INFO, ,
35 FW-1336 FW-1336 Message , [FW-1336], ,, INFO, ,
FW-1339 Recommended Action Severity 35 Run the errShow command to determine the device WWN, switch WWN, and switch port. Responses to security-class messages depend on user policies. Consult your security administrator for response strategies and policies. WARNING FW-1339 Message , [FW-1339], ,, INFO, ,
35 FW-1342 Severity INFO FW-1342 Message , [FW-1342], ,, WARNING, ,
FW-1345 35 FW-1345 Message , [FW-1345], ,, INFO, ,
35 FW-1348 Recommended Action Severity No action is required. INFO FW-1348 Message , [FW-1348], ,, INFO, ,
FW-1351 35 Probable Cause Indicates that the number of invalid signatures has risen above the high boundary. Invalid-signature violations indicate that a packet with an invalid signature has been received from the primary fabric configuration server (FCS). When the primary FCS downloads a new configuration to the other switches in the fabric, the packet is signed using the private key of the primary FCS. The receiving switch has to verify this signature with the public key of the primary FCS switch.
35 FW-1353 FW-1353 Message , [FW-1353], ,, INFO, ,
FW-1356 Recommended Action Severity 35 No action is required. INFO FW-1356 Message , [FW-1356], ,, INFO, ,
35 FW-1359 Recommended Action Severity Responses to security-class messages depend on user policies. Consult your security administrator for response strategies and policies. WARNING FW-1359 Message , [FW-1359], ,, INFO, ,
FW-1362 35 FW-1362 Message , [FW-1362], ,, WARNING, ,
35 FW-1366 Probable Cause Indicates that the number of time service (TS) out-of-sync violations has fallen below the low boundary. Recommended Action No action is required. Severity INFO FW-1366 Message , [FW-1366], ,, WARNING, ,
FW-1369 Severity 35 INFO FW-1369 Message , [FW-1369], ,, INFO, ,
35 FW-1372 Probable Cause Indicates that the number of no-FCS violations has changed from a value outside of the acceptable range to a value within the acceptable range. This counter records how often the switch loses contact with the primary fabric configuration server (FCS) switch. When the primary FCS switch in the fabric sends its certificate to a switch, the receiving switch saves the world wide name (WWN) of that primary FCS switch.
FW-1374 35 FW-1374 Message , [FW-1374], ,, WARNING, ,
35 FW-1377 FW-1377 Message , [FW-1377], ,, INFO, ,
FW-1400 Recommended Action Severity 35 No action is required. INFO FW-1400 Message , [FW-1400], ,, INFO, ,
35 FW-1403 FW-1403 Message , [FW-1403], ,, INFO, ,
FW-1427 Recommended Action Severity 35 Replace the faulty or missing power supply. WARNING FW-1427 Message , [FW-1427], ,, WARNING, , Switch status change contributing factor Power supply: bad. Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the number of faulty power supplies is greater than or equal to the policy set by the switchStatusPolicySet command.
35 FW-1430 FW-1430 Message , [FW-1430], ,, WARNING, , Switch status change contributing factor . Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the number of faulty temperature sensors is greater than or equal to the policy set by the switchStatusPolicySet command. A temperature sensor is faulty when the sensor value is not in the acceptable range or is faulty.
FW-1434 Probable Cause 35 Indicates that the switch status is not in a healthy state. This occurred because the number of faulty CPs is greater than or equal to the policy set by the switchStatusPolicySet command. The CPs are non-redundant. If you power cycle a Brocade 24000 chassis in dual-domain configuration, and then reset the micro-switch of the active CP before the heartbeat is up, this will cause both CPs to come up in a non-redundant state.
35 FW-1437 Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the number of marginal ports is greater than or equal to the policy set using the switchStatusPolicySet command. A port is faulty when the port value for Link Loss, Synchronization Loss, Signal Loss, Invalid word, Protocol error, cyclic redundancy check (CRC) error, Port state change or Buffer Limited Port is above the high boundary.
FW-1440 Severity 35 WARNING FW-1440 Message , [FW-1440], ,, INFO, , state has changed to . Probable Cause Indicates that the state of the specified field-replaceable unit (FRU) has changed to “absent”. Recommended Action No action is required. Verify that the event was planned. Severity INFO FW-1441 Message , [FW-1441], ,, INFO, , state has changed to .
35 FW-1444 Severity INFO FW-1444 Message , [FW-1444], ,, WARNING, , state has changed to . Probable Cause Indicates that the state of the specified field-replaceable unit (FRU) has changed to “faulty”. Recommended Action Replace the FRU. Severity WARNING FW-1445 Message , [FW-1445], ,, INFO, , Four power supplies are now required for 2X redundancy, Switch Status Policy values changed.
FW-1500 35 FW-1500 Message , [FW-1500], ,, WARNING, , Mail overflow - Alerts being discarded. Probable Cause Indicates that mail alert overflow condition has occurred. Recommended Action Resolve or disable the mail alert using the fwMailCfg command. Severity WARNING FW-1501 Message , [FW-1501], ,, INFO, , Mail overflow cleared - alerts discarded.
35 296 FW-1510 Fabric OS Message Reference 53-1001157-01
Chapter HAM System Messages 36 HAM-1001 Message , [HAM-1001], , FFDC, CRITICAL, , Standby CP is not healthy, device status BAD, Severity = Probable Cause Indicates that a standby control processor (CP) device error is reported by the high-availability manager (HAM) Health Monitor, with a specific device and Log="YES” Class=”NONE" Severity level. The severity level can be “critical”, “major”, or “minor”.
36 HAM-1005 • • • • • • • • • • • • • • • • • • Recommended Action Severity Fastboot Giveup Master:SYSM CP Faulty:SYSM FirmwareDownload ConfigDownload:MS ChangeWWN:EM Reboot:WebTool Fastboot:WebTool Software Fault:Software Watchdog Software Fault:Kernel Panic Software Fault:ASSERT Reboot:SNMP Fastboot:SNMP Reboot Chassis Config Reboot:API Reboot:HAM EMFault:EM Check the error log on both CPs for additional messages that might indicate the reason for the reboot.
HAM-1007 Recommended Action Severity 36 The standby CP will take over and reset the active CP. The system will be non-redundant as the standby becomes the active CP. CRITICAL HAM-1007 Message , [HAM-1007], ,, CRITICAL, ,Need to reboot the system for recovery, reason: . Probable Cause Indicates that the system in current condition needs to be rebooted to achieve a reliable recovery.
36 300 HAM-1009 Fabric OS Message Reference 53-1001157-01
Chapter HAMK System Messages 37 HAMK-1001 Message , [HAMK-1001], , FFDC, CRITICAL, , Warm recovery failed. Probable Cause Indicates the switch failed during the warm recovery. Recommended Action This message triggers a switch reboot automatically and attempts a cold recovery. RUn supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider.
37 HAMK-1004 HAMK-1004 Message ,[HAMK-1004], ,, INFO, , Resetting standby CP (double reset may occur). Probable Cause Indicates that the standby control processor (CP) is being reset due to a loss of heartbeat. This message is typically seen when the standby CP has been rebooted. Note that in certain circumstances a CP may experience a double reset and reboot twice in a row. A CP can recover automatically even if it has rebooted twice.
Chapter HIL System Messages 38 HIL-1101 Message , [HIL-1101], ,, ERROR, , Slot faulted, () is above threshold. Probable Cause Indicates that the blade voltage is above the threshold. Recommended Action Replace the faulty blade or switch (for nonbladed switches).
38 HIL-1104 HIL-1104 Message , [HIL-1104], ,, ERROR, , Blower faulted, () is below threshold. Probable Cause Indicates that the fan voltage is below the threshold. Recommended Action Run the psShow command to verify the power supply status. Try to reseat the faulty fan field-replaceable unit (FRU) and power supply FRU to verify that they are seated properly.
HIL-1107 38 HIL-1107 Message , [HIL-1107], ,, ERROR, , Switch faulted, ()above threshold. Probable Cause Indicates that the switch voltage is above threshold. This message is specific to nonbladed switches and is not applicable to the Brocade 24000 or 48000.
38 HIL-1202 If the fan continues to generate this message, replace the fan FRU. Severity WARNING HIL-1202 Message , [HIL-1202], ,, ERROR, , Blower faulted, speed ( RPM) below threshold. Probable Cause Indicates that the specified fan speed (in RPMs) has fallen below the minimum threshold. Recommended Action Replace the fan field-replaceable unit (FRU).
HIL-1206 38 HIL-1206 Message , [HIL-1206], ,, ERROR, , Fan sensor , speed ( RPM) below threshold. Probable Cause Indicates that the specified fan speed (in RPMs) has fallen below the minimum threshold. This problem can quickly cause the switch to overheat. This message is specific to nonbladed switches and is not applicable to the Brocade 24000 or 48000.
38 HIL-1301 HIL-1301 Message , [HIL-1301], ,, WARNING, , 1 blower failed or missing. Replace failed or missing blower assembly immediately. Probable Cause Indicates that a fan field-replaceable unit (FRU) has failed or has been removed. This message is often preceded by a low speed error message. This problem can cause the switch to overheat. Recommended Action Replace the affected fan FRU immediately.
HIL-1305 Severity 38 ERROR HIL-1305 Message , [HIL-1305], ,, ERROR, , One or two fans failed. Replace failed fan FRUs immediately. Probable Cause Indicates that multiple fan field-replaceable units (FRUs) have failed. This message is often preceded by a low fan speed message. Recommended Action Replace the faulty fan FRUs immediately. Severity ERROR HIL-1306 Message , [HIL-1306], ,, ERROR, , Three fans failed.
38 HIL-1309 Recommended Action Severity Replace the faulty fan field-replaceable units (FRUs) immediately. ERROR HIL-1309 Message , [HIL-1309], ,, ERROR, , fan FRUs failed. Replace failed fan FRUs immediately. Probable Cause Indicates that multiple fans have failed. This message is often preceded by a low fan speed message. Recommended Action Replace the faulty fan field-replaceable unit (FRU)s immediately.
HIL-1402 Probable Cause Indicates that one fan field-replaceable unit (FRU) has been removed. Recommended Action Install the missing fan FRU. Severity 38 WARNING HIL-1402 Message , [HIL-1402], ,, WARNING, , Two fan FRUs missing. Install fan FRUs immediately. Probable Cause Indicates that two fan field-replaceable units (FRUs) have been removed. Recommended Action Install the missing fan FRUs immediately.
38 HIL-1502 Recommended Action Severity Run the fanShow command to verify all the fans are working properly. Make sure that the area is well-ventilated and that the room temperature is within operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range. WARNING HIL-1502 Message , [HIL-1502], , FFDC, CRITICAL, , Slot , high temperature ().
HIL-1505 Recommended Action Severity 38 No action is required. INFO HIL-1505 Message , [HIL-1505], ,, WARNING, , High temperature ( C) exceeds environmental specifications. Probable Cause Indicates that temperatures in the system have risen above the warning threshold. Recommended Action Run the fanShow command to verify all the fans are working properly.
38 HIL-1508 HIL-1508 Message , [HIL-1508], , FFDC, CRITICAL, , Fan faulty warning time expired. System preparing for shutdown. Probable Cause Indicates that temperatures in the system have remained above the critical threshold too long. Recommended Action To avoid causing damage to the switch, the system shuts down automatically. To help prevent future problems, make sure that all the fans are working properly.
HIL-1601 38 HIL-1601 Message , [HIL-1601], ,, ERROR, , Using backup temperature sensor. Service immediately. Probable Cause Indicates that temperature readings from the primary sensor are out of range. Recommended Action Run the fanShow command to verify that all fans are operating correctly. Replace any deteriorating fan field-replaceable units (FRUs). Run the tempShow command to verify temperature values. If any sensor is too high, monitor the switch.
38 HIL-1650 Recommended Action Severity Ensure the power cord is connected to the unit with a valid power source and then switch on the unit. If the problem persists, try reseating the unit. If the problem still persists replace the FRU. WARNING HIL-1650 Message , [HIL-1650], , ERROR, , unable to detect both WWN cards in chassis. Access to WWN halted. Probable Cause One or both of the WWN cards is missing.
Chapter HLO System Messages 39 HLO-1001 Message , [HLO-1001], , FFDC, ERROR, , Incompatible Inactivity timeout from port , correct value . Probable Cause Indicates that the HLO message was incompatible with the value specified in the FSPF protocol. The Brocade switch will not accept FSPF frames from the remote switch.
39 HLO-1003 The switch has received an invalid HLO because either the domain or port number in the HLO message has an invalid value. This error can only occur when the Brocade switch is connected to a switch from another manufacturer. Recommended Action 318 The HLO message of the remote switch must be compatible with the value specified in the FSPF protocol. Refer to the documentation for the other manufacturer's switch to change this value.
Chapter HMON System Messages 40 HMON-1001 Message , [HMON-1001], , FFDC, CRITICAL, , Probable Cause Indicates there was a problem reading an essential file containing configuration information from the nonvolatile storage device. This could be the result of a missing file or a corrupt file system. Recommended Action Run the firmwareDownload command to reinstall the firmware to your switch.
40 320 HMON-1001 Fabric OS Message Reference 53-1001157-01
Chapter HTTP System Messages 41 HTTP-1001 Message , [HTTP-1001], ,, INFO, , Switch PIDformat has changed to . Probable Cause Indicates that the PID format was changed by the administrator. Recommended Action No action is required. For more information on PID format, refer to the Fabric OS Administrator’s Guide.
41 322 HTTP-1003 Fabric OS Message Reference 53-1001157-01
Chapter IBD System Messages 42 IBD-1001 Message , [FKLB-1001], ,, ERROR, , Slot , Port GE: Maximum attempts to restart failed. Disabling port. Probable Cause Indicates that the specified port has crashed unexpectedly and restarting attempts have failed. Recommended Action Power off and power on the blade using the slotPowerOff and slotPowerOn commands.
42 324 IBD-1001 Fabric OS Message Reference 53-1001157-01
Chapter IBPD System Messages 43 IBPD-1001 Message , [IBPD-1001], ,, WARNING, , : initiator name length exceeds the character limit [] Probable Cause Indicates that the initiator name length exceeds the supported limit of characters. Recommended Action Change the initiator name, keeping the number of characters within the supported limit.
43 326 IBPD-1003 Fabric OS Message Reference 53-1001157-01
Chapter ICPD System Messages 44 ICPD-1001 Message , [ICPD-1001], ,, ERROR, , Failed to allocate memory: (). Probable Cause Indicates that the specified function failed to allocate memory. Recommended Action Check memory usage on the switch using the memShow command. Severity Reboot or power cycle the switch.
44 ICPD-1005 Recommended Action Severity Enable the iSNS Client service on a single switch in the fabric using the fosConfig command. Refer to the Fabric OS Command Reference for more information on this command. WARNING ICPD-1005 Message , [ICPD-1005], ,, WARNING, , iSCSI configuration between local switch () and peer () is out of sync. iSCSI login is not allowed.
ICPD-1008 Recommended Action Severity 44 No action is required.
44 330 ICPD-1008 Fabric OS Message Reference 53-1001157-01
Chapter IPAD System Messages 45 IPAD-1000 Message , [IPAD-1000], ,, INFO,
45 332 IPAD-1001 Fabric OS Message Reference 53-1001157-01
Chapter IPS System Messages 46 IPS-1001 Message , [IPS-1001], ,, WARNING, , FCIP License Not Installed () Probable Cause Indicates the FCIP license is not installed on the switch. Recommended Action Run the licenseShow command to check the installed licenses on the switch. Contact your switch supplier for a FCIP license. Run the licenseAdd command to add the license to your switch.
46 IPS-1005 Probable Cause Indicates that configured Port Mode is different from the intended use. Recommended Action Change the port configuration (by deleting configured FCIP tunnels or iSCSI sessions) to return the port mode to neutral before attempting to configure the port for a different mode or use.
Chapter ISCS System Messages 47 ISCS-1000 Message , [ISCS-1000], ,, ERROR, , Slot Port GE crashed unexpectedly. Probable Cause Indicates the specified port has crashed. Recommended Action No action is required; the port will restart automatically.
47 336 ISCS-1000 Fabric OS Message Reference 53-1001157-01
Chapter ISNS System Messages 48 ISNS-1001 Message , [ISNS-1001], ,, INFO, , Configuration peering with external iSNS server slot/port /ge (current /ge). Probable Cause Indicates that the user has issued the isnscCfg command. Recommended Action No action is required.
48 ISNS-1004 ISNS-1004 Message , [ISNS-1004], ,, WARNING, , Timeout refreshing iSNS database with iSNS server slot/port /ge Reg-Period . Probable Cause Indicates that the internet storage name service (iSNS) client failed to receive a successful response for a DevAttrQry within the specified Registration-Period.
ISNS-1009 Recommended Action Severity 48 No action is required. You may change the configuration and retry the peering with the external iSNS server. INFO ISNS-1009 Message , [ISNS-1009], ,, INFO, , Peering with external iSNS server not started because no virtual targets found. Probable Cause Indicates that no virtual targets were found, so peering was not started. Recommended Action No action is required.
48 ISNS-1014 Probable Cause Indicates that the internet storage name service (iSNS) client failed to establish a connection with the iSNS server. Recommended Action Verify the connection of the iSNS server to the slot/port. Use the isnscCfg command to display or correct the server IP address. Severity WARNING ISNS-1014 Message , [ISNS-1014], ,, INFO, , Start peering with external iSNS server on management port.
Chapter KAC System Messages 49 KAC-1002 Message , [KAC-1002], ,, ERROR, , KAC() communication Error: Error connecting to . Probable Cause Indicates that the key archival client is unable to communicate with the primary or backup key vault. Recommended Action Determine whether the configured key value is operational, and if it is not, change the switch key vault settings.
49 KAC-1008 Probable Cause Indicates that the key archival client is unable to put to the primary or backup key vault. Recommended Action Determine whether the configured key value is operational, and if it is not, change the switch key vault settings. Severity ERROR KAC-1008 Message , [KAC-1008], ,, ERROR, , Putting TEP failed check if there is already an unapproved TEP then delete it, RC=.
Chapter KSWD System Messages 50 KSWD-1001 Message , [KSWD-1001], , FFDC, WARNING, , : failed to refresh (:). Probable Cause Indicates one of the critical daemons is found to be nonresponsive. An abort signal is sent. Recommended Action Copy the warning message along with any core file information, and contact your switch service provider.
50 KSWD-1003 Recommended Action SIGABRT is the signal thrown by the programs to abort the process. Run the supportSave command to determine if any core files were created. If a core file is found, run supportFtp to send all core files to a secure server location. Copy the warning message along with any core file information, and contact your switch service provider.
Chapter KTRC System Messages 51 KTRC-1001 Message , [KTRC-1001], ,, WARNING, , Dump memory size exceeds dump file size Probable Cause Indicates the dump memory size has exceeded the dump file size. Recommended Action No action is required. Severity WARNING KTRC-1002 Message , [KTRC-1002], ,, INFO, , Concurrent trace dumping. Probable Cause Indicates the initial background dump has not completed.
51 KTRC-1005 Recommended Action Severity No action is required. ERROR KTRC-1005 Message , [KTRC-1005], ,, ERROR, , Trace initialization failed. . . Probable Cause Indicates that a trace was unable to initialize. Recommended Action No action is required.
Chapter LFM System Messages 52 LFM-1001 Message , [LFM-1001], ,, INFO, , The Logical Fabric Manager service is disabled. Probable Cause Indicates that the Logical Fabric Manager service is disabled. Note that the Logical Fabric Manager service is enabled by the factory setting and it is not user configurable. Recommended Action No action is required.
52 LFM-1004 LFM-1004 Message , [LFM-1004], ,, CRITICAL, , HA is out of sync for opcode , error value . Probable Cause Indicates the trigger for some internal logging purpose. Recommended Action Send the ffdc log to the support. Severity CRITICAL LFM-1005 Message , [LFM-1005], ,, WARNING, , Logical port disabled with reason ().
Chapter LOG System Messages 53 LOG-1000 Message , [LOG-1000], ,, INFO, , Previous message repeated times Probable Cause Indicates the previous message repeated the specified number of times. Recommended Action No action is required. Severity INFO LOG-1001 Message , [LOG-1001], , FFDC, WARNING, , A log message was dropped Probable Cause Indicates a log message was dropped.
53 LOG-1003 LOG-1003 Message , [LOG-1003], ,, INFO, , The log has been cleared. Probable Cause Indicates the persistent error log has been cleared. Recommended Action No action is required.
Chapter LSDB System Messages 54 LSDB-1001 Message , [LSDB-1001], ,, ERROR, , Link State ID out of range Probable Cause Indicates the specified link state database ID is out of the acceptable range. The valid link state ID is the same as the valid domain ID, whose range is from 1 through 239. The switch will discard the record because it is not supported. Recommended Action No action is required.
54 LSDB-1004 Severity CRITICAL LSDB-1004 Message , [LSDB-1004], ,, WARNING, , No Link State Record for domain Probable Cause Indicates there is no link state record for the specified local domain. Recommended Action No action is required. The other switch will pass the LSD once the fabric is stable.
Chapter MFIC System Messages 55 MFIC-1001 Message , [MFIC-1001], ,, ERROR, , failure at sysmod_scn registry rc= Probable Cause Indicates the system is temporarily out of resources. Recommended Action No action is required; this message is often transitory. If the message persists, run a switch reboot or an haFailover command (if applicable).
55 MFIC-1003 Recommended Action IDID mode is a fabric-wide mode; make sure that any switches added to the fabric are configured with the same IDID mode as the fabric. If you are enabling or disabling IDID mode, this message is for information purposes only, and no action is required. IDID mode can be set using the configure command in the CLI or checking the Advanced Web Tools Switch Admin > Configure Tab > Fabric Subtab > Insistent Domain ID Mode check box.
Chapter MPTH System Messages 56 MPTH-1001 Message , [MPTH-1001], , FFDC, ERROR, , Null parent, lsId = Probable Cause Indicates a null parent was reported. MPATH uses a tree structure in which the parent is used to connect to the root of the tree. Recommended Action No action is required.
56 356 MPTH-1003 Fabric OS Message Reference 53-1001157-01
Chapter MQ System Messages 57 MQ-1004 Message Probable Cause , [MQ-1004], ,, ERROR, , mqRead, queue = , queue ID = , type = Indicates an unexpected message has been received in the specified message queue. The queue name is always fspf_q.
57 358 MQ-1004 Fabric OS Message Reference 53-1001157-01
Chapter MS System Messages 58 MS-1001 Message , [MS-1001], ,, WARNING, , MS Platform Segmented port= () ( ()) Probable Cause Indicates the management server (MS) has segmented from another switch domain at the specified port number because of errors or inconsistencies defined in the MS platform service. Recommended Action Reboot or power cycle the switch.
58 MS-1003 • Run the firmwareDownload command to upgrade the firmware level on the switch to a level that supports RCS. RCS is supported in Fabric OS v2.6, v3.1 and greater, and v4.1 and greater. • Wait a few minutes and try the command again. Severity INFO MS-1003 Message Probable Cause , [MS-1003], ,, INFO, , MS detected Unstable Fabric().
MS-1005 Severity 58 INFO MS-1005 Message , [MS-1005], ,, ERROR, , MS Invalid CT Response from d= Probable Cause Indicates the management server (MS) received an invalid common transport (CT) response from the switch domain. MS expects either a CT accept IU or a reject IU; the MS received neither response, which violates the Fibre Channel Generic Services (FS-GS) specification.
58 MS-1009 MS-1009 Message Probable Cause , [MS-1009], ,, ERROR, , RLIR event. Switch Port ID is (). Device Port Tag is . . Indicates a registered link incident record (RLIR) has been generated for one of the actions indicated by the . The following messages will be displayed: • • • • • Recommended Action Severity Exceeded bit error rate threshold Loss of signal or synchronization Not operational seq.
MS-1023 58 MS-1023 Message , [MS-1023], ,, INFO, , Management Server Topology Discovery Service . Probable Cause Indicates Management Server Topology Discovery Service is being enabled or disabled. Recommended Action No action is required. Severity INFO MS-1024 Message , [MS-1024], ,, INFO, , Management Server Access Control List is Updated.
58 364 MS-1024 Fabric OS Message Reference 53-1001157-01
Chapter NBFS System Messages 59 NBFS-1001 Message Probable Cause , [NBFS-1001], ,, INFO, , Duplicate E_Port SCN from port in state () Indicates a duplicate E_Port State Change Number was reported.
59 NBFS-1003 Severity ERROR NBFS-1003 Message Probable Cause , [NBFS-1003], ,, WARNING, , DB_XMIT_SET flag not set in state , input , port Indicates the database transmit set flag was not set for the specified input state on the specified port.
Chapter NS System Messages 60 NS-1001 Message , [NS-1001], ,, WARNING, , The response for request 0x from remote switch 0x is larger than the max frame size the remote switch can support! Probable Cause Indicates the response payload exceeds the maximum frame size the remote switch can handle. Recommended Action Run the firmwareDownload command to upgrade the remote switch with firmware v4.
60 NS-1004 Reduce the local device count to follow the capability of the lowest version of firmware. Severity INFO NS-1004 Message , [NS-1004], ,, INFO, , Number of local devices , exceeds the standby can support , can't sync.
Chapter PDM System Messages 61 PDM-1001 Message , [PDM-1001], ,, WARNING, , Failed to parse the pdm config. Probable Cause Indicates the parity data manager (PDM) process could not parse the configuration file. This might be caused by a missing configuration file during the installation. Recommended Action Run the firmwareDownload command to reinstall the firmware.
61 PDM-1004 PDM-1004 Message , [PDM-1004], ,, WARNING, , PDM memory shortage. Probable Cause Indicates the parity data manager (PDM) process ran out of memory. Recommended Action Reboot or power cycle the switch. Severity If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider.
PDM-1008 Recommended Action Severity 61 Run the firmwareDownload command to reinstall the firmware. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. WARNING PDM-1008 Message , [PDM-1008], ,, WARNING, , Failed to get the number of U_Ports. Probable Cause Indicates the parity data manager (PDM) system call to getCfg failed.
61 PDM-1011 PDM-1011 Message , [PDM-1011], ,, WARNING, , File read failed: , Length(read=, expected=), errno=. Probable Cause Indicates the parity data manager (PDM) process could not read data from the specified file. Recommended Action Run the firmwareDownload command to reinstall the firmware.
PDM-1017 Recommended Action Severity 61 Run the firmwareDownload command to reinstall the firmware. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. WARNING PDM-1017 Message , [PDM-1017], , FFDC, CRITICAL, , System (): . Probable Cause Indicates the specified system call failed.
61 PDM-1022 Probable Cause Indicates a system call failed. Recommended Action Run the firmwareDownload command to reinstall the firmware. Severity If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. WARNING PDM-1022 Message , [PDM-1022], ,, WARNING, , The switch is configured only with IPv6.
PDM-1024 Fabric OS Message Reference 53-1001157-01 61 375
61 376 PDM-1024 Fabric OS Message Reference 53-1001157-01
Chapter PDTR System Messages 62 PDTR-1001 Message , [PDTR-1001], ,, INFO, , . Probable Cause Indicates information has been written to the panic dump files. The watchdog register codes are as follows: • 0x10000000 bit set means that the watch dog timer (WDT) forced a core reset. • 0x20000000 bit set means that the WDT forced a chip reset. • All other code values are reserved.
62 378 PDTR-1002 Fabric OS Message Reference 53-1001157-01
Chapter PLAT System Messages 63 PLAT-1000 Message , [PLAT-1000], , FFDC, CRITICAL, , Probable Cause Indicates nonrecoverable PCI errors have been detected. Recommended Action The system will be faulted and might automatically reboot. If the system does not reboot, then try issuing the reboot command from a command-line prompt.
63 PLAT-1003 Severity CRITICAL PLAT-1003 Message , [PLAT-1003], , FFDC, CRITICAL, , Slot C/BE: ADBUS: misc_intr . Probable Cause Indicates a PCI bus hang was detected. Recommended Action The FRU must be replaced.
Chapter PMGR System Messages 64 PMGR-1001 Message , [PMGR-1001], , INFO, , Switch was successfully created. Probable Cause Indicates the switch with the specified FID was successfully created. Recommended Action No action is required. Severity INFO PMGR-1002 Message , [PMGR-1002], , WARNING, , Switch failed to create. Error message: .
64 PMGR-1005 Recommended Action Severity No action is required. WARNING PMGR-1005 Message , [PMGR-1005], , INFO, , Ports on slot to switch were moved successfully. Probable Cause Indicates the successful attempt to move the ports to the specified switch. Recommended Action No action is required.
PMGR-1009 Recommended Action Severity 64 No action is required. WARNING PMGR-1009 Message , [PMGR-1009], , INFO, , The base switch was successfully changed to switch . Probable Cause Indicates the successful change of the base switch. Recommended Action No action is required. Severity INFO PMGR-1010 Message , [PMGR-1010], , WARNING, , The base switch failed to change to switch .
64 384 PMGR-1010 Fabric OS Message Reference 53-1001157-01
Chapter PORT System Messages 65 PORT-1003 Message , [PORT-1003], ,, WARNING, , Port Faulted because of many Link Failures Probable Cause Indicates the specified port is now disabled because the link on this port had multiple failures that exceeded an internally set threshold on the port. This problem is typically related to hardware.
65 PORT-1005 Recommended Action Severity 386 Invoke the portCfgLport to clear the L_port configuration.
Chapter PS System Messages 66 PS-1000 Message , [PS-1000], , FFDC, CRITICAL, , Failed to initialize Advanced Performance Monitoring. Probable Cause Indicates an unexpected software error has occurred in Advanced Performance Monitoring. The Performance Monitor has failed to initialize. Recommended Action The CP should reboot (or fail over) automatically. If it does not, reboot or power cycle the switch to reinitiate the firmware.
66 PS-1004 Probable Cause Indicates that the restoring configuration has attempted to set the end-to-end monitoring mask on at least one ISL port. Recommended Action No action is required. End-to-end monitoring is not supported on ISL ports when ISL monitoring is enabled. ISL monitoring can only be disabled through the Fabric Access API.
Chapter PSWP System Messages 67 PSWP-1001 Message , [PSWP-1001], ,, INFO, , Areas for port and port are swapped. New area for port is and port is . Probable Cause Indicates the portSwap command has been issued.
67 390 PSWP-1003 Fabric OS Message Reference 53-1001157-01
Chapter RAS System Messages 68 RAS-1001 Message , [RAS-1001], ,, INFO, , First failure data capture (FFDC) event occurred. Probable Cause Indicates that a failure happened and the failure data was captured. Recommended Action Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider.
68 RAS-1006 Probable Cause Indicates an internal software error. Recommended Action Run the supportSave command and contact your switch service provider. Severity WARNING RAS-1006 Message , [RAS-1006], , INFO, , Support data file () automatically transferred to remote address ' '. Probable Cause Indicates that the support data file is transferred from the switch automatically.
RAS-3001 Probable Cause A user has changed the configured classes of the audit feature. Recommended Action No action is required. Severity 68 INFO RAS-3001 Message , [RAS-3001], , INFO, , USB storage device plug-in detected. Probable Cause Indicates that the USB storage device plug-in is being detected. Recommended Action No action is required.
68 RAS-3004 Recommended Action Severity 394 No action is required.
Chapter RCS System Messages 69 RCS-1001 Message , [RCS-1001], ,, INFO, , RCS has been disabled. Some switches in the fabric do not support this feature. Probable Cause Indicates the RCS feature has been disabled on the local switch because not all switches in the fabric support RCS or the switch is in nonnative mode. Recommended Action Run the rcsInfoShow command to view RCS capability on the fabric. RCS is supported in Fabric OS v2.6, v3.
69 RCS-1004 RCS-1004 Message , [RCS-1004], ,, ERROR, , Application() not registered.() Probable Cause Indicates a specified application did not register with RCS. Recommended Action Run the haShow command to view the HA state. Run the haDisable and the haEnable commands. Run the rcsInfoShow command to view RCS capability on the fabric. RCS is supported in Fabric OS v2.6, v3.1 and greater, and v4.1 and greater.
RCS-1007 Severity 69 INFO RCS-1007 Message , [RCS-1007], ,, ERROR, , Zone DB size and propogation overhead exceeds domain 's maximum supported Zone DB size . Retry after reducing the Zone DB size. Probable Cause Indicates a domain cannot handle the zone database being committed. Recommended Action Reduce the zone database size.
69 398 RCS-1008 Fabric OS Message Reference 53-1001157-01
Chapter RKD System Messages 70 RKD-1001 Message , [RKD-1001], ,, INFO, , operation .\nTarget: , Initiator: , LUN ID: .\n SessionId:/ Probable Cause Indicates that a First time encryption/re-key/Write Metadata was started/completed/cancelled. Recommended Action No action is required.
70 400 RKD-1003 Fabric OS Message Reference 53-1001157-01
Chapter RPCD System Messages 71 RPCD-1001 Message , [RPCD-1001], ,, WARNING, , Authentication Error: client \"\" has bad credentials: Probable Cause Indicates an authentication error was reported. The specified client IP address has faulty credentials. Recommended Action Enter the correct user name and password from the Fabric Access API host.
71 RPCD-1004 RPCD-1004 Message , [RPCD-1004], ,, WARNING, , Invalid certificate file. Secure RPCd is disabled. Probable Cause Indicates the SSL certificate file has been corrupted. Recommended Action To enable RPCD in Secure mode, install a valid SSL certificate the switch. Severity WARNING RPCD-1005 Message , [RPCD-1005], ,, WARNING, , Missing private key file. Secure RPCd is disabled.
Chapter RTWR System Messages 72 RTWR-1001 Message , [RTWR-1001], ,, ERROR, , RTWR 0x, 0x, 0x, 0x, 0x Probable Cause Indicates that an error occurred in the RTWR. The message provides the name of the routine having the error, and more specific error information. The values in details 1 through 5 might provide more information. Recommended Action No action is required.
72 RTWR-1003 RTWR-1003 Message , [RTWR-1003], ,, INFO, , : RTWR retry to domain , iu_data Probable Cause Indicates how many times RTWR failed to get a response and retried. Recommended Action Run the dom command to verify that the specified domain ID is reachable.
Chapter SAS System Messages 73 SAS-1001 Message , [SAS-1001], ,, ERROR, , string description of command which failed> of GE failed. Please retry the command. Data inst= st= rsn= fn= oid=. Probable Cause The Hardware is not responding to the command request; possibly because it is busy. Recommended Action Retry the command.
73 406 SAS-1001 Fabric OS Message Reference 53-1001157-01
Chapter SCN System Messages 74 SCN-1001 Message Probable Cause , [SCN-1001], , FFDC, CRITICAL, , SCN queue overflow for process Indicates that an attempt to write a state change notification (SCN) message to a specific queue has failed because the SCN queue for the specified daemon name is full. This might be caused by the daemon hanging or the system being busy. Some valid values for daemon name are listed below.
74 408 SCN-1001 Fabric OS Message Reference 53-1001157-01
Chapter SEC System Messages 75 SEC-1001 Message , [SEC-1001], ,, ERROR, , RCS process fails: Probable Cause Indicates that the reliable commit service (RCS) process failed to complete. RCS is a mechanism for transferring data from one switch to other switches within the fabric. RCS ensures that either all or none of the switches commit to the database.
75 SEC-1003 SEC-1003 Message , [SEC-1003], ,, WARNING, , Fail to download security data to domain after retries Probable Cause Indicates the specified domain failed to download security data after the specified number of attempts, and that the failed switch encountered an error accepting the database download. The primary switch will segment the failed switch after 30 tries.
SEC-1007 75 SEC-1007 Message , [SEC-1007], ,, INFO, , Security violation: Unauthorized host with IP address tries to establish API connection. Probable Cause Indicates a security violation was reported. The IP address of the unauthorized host is displayed in the message. Recommended Action Check for unauthorized access to the switch through the API connection.
75 SEC-1022 Recommended Action Severity Check for unauthorized access to the switch through the SSH connection. INFO SEC-1022 Message , [SEC-1022], ,, WARNING, , Failed to PKI objects. Probable Cause Indicates the fabric failed to generate or validate either the public or private key pair or the certificate signing request (CSR).
SEC-1026 75 SEC-1026 Message , [SEC-1026], ,, ERROR, , Invalid format or character in switch member . Probable Cause Indicates a corruption occurred during the distribution of the security database. This can occur only when the primary fabric configuration server (FCS) distributes the security database to the other switches in the fabric, then local validation finds the error in the security database. This is a rare occurrence.
75 SEC-1030 SEC-1030 Message , [SEC-1030], , ERROR, , The length of the name invalid. Probable Cause Indicates a corruption occurred during the distribution of the security database. This can occur only when the primary fabric configuration server (FCS) distributes the security database to the other switches in the fabric, then local validation finds the error in the security database. This is a rare occurrence.
SEC-1034 75 Probable Cause Indicates a member parameter in the secPolicyAdd command is invalid (e. g., it may include an invalid character, such as an asterisk). A valid switch identifier (a WWN, a domain ID, or a switch name) must be provided as a member parameter in the secPolicyAdd command. Only the secPolicyCreate command supports use of the asterisk for adding switches to policies.
75 SEC-1037 SEC-1037 Message , [SEC-1037], ,, ERROR, , Invalid WWN format . Probable Cause Indicates the world wide name (WWN) entered in the policy member list had an invalid format. Recommended Action Run the command again using the standard WWN format, 16 hexadecimal digits grouped as eight colon separated pairs. For example: 50:06:04:81:D6:F3:45:42.
SEC-1042 Severity 75 ERROR SEC-1042 Message , [SEC-1042], ,, ERROR, , Invalid index/area member in portlist (). Out of range ( - ). Probable Cause Indicates the specified index or area member is not within the minimum and maximum range. Recommended Action Use valid syntax when entering index or area numbers.
75 SEC-1046 Recommended Action Severity Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in the ready state. If a switch is in the error state, the database might not be correctly updated for that specific switch. ERROR SEC-1046 Message , [SEC-1046], ,, ERROR, , Empty list. Probable Cause Indicates there has been a corruption during the distribution of the security database.
SEC-1051 Severity 75 ERROR SEC-1051 Message , [SEC-1051], ,, ERROR, , Missing brace for port list . Probable Cause Indicates there has been a corruption during the distribution of the security database. This can only occur when the primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence.
75 SEC-1054 SEC-1054 Message , [SEC-1054], ,, ERROR, , Invalid FCS list length Probable Cause Indicates there has been a corruption during the distribution of the security database. This can only occur when the primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence.
SEC-1057 75 SEC-1057 Message , [SEC-1057], ,, ERROR, , No change. Both positions are the same. Probable Cause Indicates there has been a corruption during the distribution of the security database. This can only occur when the primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence.
75 SEC-1064 Severity ERROR SEC-1064 Message , [SEC-1064], ,, ERROR, , Failed to sign message. Probable Cause Indicates the public key infrastructure (PKI) objects on the switch are not in a valid state and the signature operation failed. Recommended Action Run the pkiShow command to verify that all PKI objects are valid. If PKI objects are not valid, generate the PKI objects and install the certificate by following the field upgrade process.
SEC-1072 Severity 75 ERROR SEC-1072 Message , [SEC-1072], ,, ERROR, , Policy List is Empty! Probable Cause Indicates the specific policy type is empty. The security database is corrupted for unknown reasons. Recommended Action Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider.
75 SEC-1076 Probable Cause Indicates there has been a corruption during the distribution of the security database. This can only occur when the primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Recommended Action Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in the ready state.
SEC-1079 75 SEC-1079 Message , [SEC-1079], ,, ERROR, , The policy name is invalid. Probable Cause Indicates the policy name entered in the secPolicyCreate|Activate|Add|Delete command was invalid. Recommended Action Run the command again using a valid policy name. Severity ERROR SEC-1080 Message , [SEC-1080], ,, ERROR, , Operation denied. Please, use secModeEnable command.
75 SEC-1083 Recommended Action Severity Use proper syntax when creating policies. If the security database is too large, you must delete other members within the database before adding new members to a policy. ERROR SEC-1083 Message , [SEC-1083], ,, ERROR, , Name already exists. Probable Cause Indicates there has been a corruption during the distribution of the security database.
SEC-1087 Probable Cause Indicates the security database has more data than the flash can accommodate. Recommended Action Reduce the number of entries in some policies to decrease the security database size. Severity 75 ERROR SEC-1087 Message , [SEC-1087], ,, ERROR, , The security database is larger than the data distribution limit of fabric bytes.
75 SEC-1090 SEC-1090 Message , [SEC-1090], ,, ERROR, , SCC list contains FCS member. Please remove member from the FCS policy first. Probable Cause Indicates there has been a corruption during the distribution of the security database. This can only occur when the primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database.
SEC-1094 75 Probable Cause Indicates the new fabric configuration server (FCS) list does not have a common member with the existing FCS list. Recommended Action Resubmit the command with at least one member of the new FCS list in common with the current FCS list. Severity ERROR SEC-1094 Message , [SEC-1094], ,, ERROR, , Policy member not found. Probable Cause Indicates there has been a corruption during the distribution of the security database.
75 SEC-1097 Severity ERROR SEC-1097 Message , [SEC-1097], ,, ERROR, , Cannot find policy set. Probable Cause Indicates the specified policy could not be found. Recommended Action If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider.
SEC-1101 75 Probable Cause Indicates there has been a corruption during the distribution of the security database. This can only occur when the primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Recommended Action Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in the ready state.
75 SEC-1105 Severity ERROR SEC-1105 Message , [SEC-1105], ,, ERROR, , Fail to disable secure mode on all switches. Probable Cause Indicates the switch failed to disable security in the fabric. This could happen if the switch cannot get the required resources to complete the command, and sending to a remote domain fails or the remote domain returns an error.
SEC-1110 75 Probable Cause Indicates that a version reset operation failed either because the switch could not get all the required resources to perform the operation or because it failed to send the message to all switches in the fabric. Recommended Action Verify that the security event was planned. If the security event was planned, run the secFabricShow command to verify that all switches in the fabric are in the ready state. When all switches are in the ready state, retry the operation.
75 SEC-1113 Recommended Action Severity Make sure that the new FCS policy is the same as the current FCS policy on the switch. ERROR SEC-1113 Message , [SEC-1113], ,, WARNING, , [ license ] going to expire in days. Probable Cause Indicates the license period will expire soon. Recommended Action Get a new license for this feature.
SEC-1117 75 Probable Cause Indicates there has been a corruption during the distribution of the security database. This can only occur when the primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Recommended Action Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in the ready state.
75 SEC-1121 SEC-1121 Message , [SEC-1121], ,, ERROR, , Time is out of range when . Probable Cause Indicates the time on the switch is not synchronized with the primary fabric configuration server (FCS), the data packet is corrupted, or a replay attack is launched on the switch. Recommended Action Verify the security event was planned.
SEC-1126 Severity 75 INFO SEC-1126 Message , [SEC-1126], ,, INFO, , Secure mode has been disabled. Probable Cause Indicates that a secure mode disable operation completed successfully. Recommended Action Verify the security event was planned. If the security event was planned, no action is required. If the security event was not planned, take appropriate action as defined by your enterprise security policy.
75 SEC-1137 Probable Cause Indicates the receiving switch fails to validate the security database sent from the primary fabric configuration server (FCS) switch. This message usually indicates that the data package is corrupted, the time stamp on the package is out of range as a result of a replay attack or out-of-sync time service, or the signature verification failed. Signature verification failure indicates either an internal error (such as losing the primary public key) or an invalid database.
SEC-1142 75 Probable Cause Indicates that the receiving switch failed to validate the security database sent from the primary fabric configuration server (FCS) switch. This message usually indicates that the data package is corrupted, the time stamp on the package is out of range as a result of a replay attack or out-of-sync time service, or the signature verification failed. Signature verification failure indicates either an internal error (such as losing the primary public key) or an invalid database.
75 SEC-1153 Probable Cause Indicates the PID format of the switch was changed either to extended-edge PID or from extended-edge PID. If the device connection control (DCC) polices existed, all index/area ID values either increased or decreased by 16. The values wrap around after 128. If a DCC policy contains an index/area of 127 before changing to extended-edge PID, then the new index/area is 15, because of the wraparound. Recommended Action No action is required.
SEC-1156 75 Probable Cause Indicates that either the defined or active policy was too large after modifying the index/area ID. The status values can be either defined, active, or both. A negative value means that a policy set was failed by the daemon. Recommended Action Reduce the size of the specified policy database. Severity INFO SEC-1156 Message , [SEC-1156], ,, INFO, , Change failed: .
75 SEC-1159 SEC-1159 Message , [SEC-1159], ,, INFO, , Non_Reachable domain . Probable Cause Indicates there has been a corruption during the distribution of the security database. This can only occur when the primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence.
SEC-1165 Severity 75 ERROR SEC-1165 Message , [SEC-1165], ,, ERROR, , Low memory, failed to enable security on all switches. Probable Cause Indicates the system is low on memory. Recommended Action Wait a few minutes and try the command again. Severity ERROR SEC-1166 Message , [SEC-1166], ,, ERROR, , Non FCS tries to commit failover.
75 SEC-1170 Probable Cause Indicates there has been a corruption during the distribution of the security database. This can only occur when the primary fabric configurations server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Recommended Action Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in the ready state.
SEC-1173 Recommended Action Severity 75 Verify all switches in the fabric are in time synchronization with the primary and that no external entity is trying to access the fabric. When verification is complete, retry the operation. ERROR SEC-1173 Message , [SEC-1173], ,, ERROR, , Lost contact with Primary FCS switch. Probable Cause Indicates the switch has lost contact with the primary fabric configuration server (FCS) switch in the secure fabric.
75 SEC-1180 Recommended Action Severity Verify all switches in the fabric are in time synchronization with the primary and that no external entity is trying to access the fabric. When verification is complete, retry the operation. ERROR SEC-1180 Message , [SEC-1180], ,, INFO, , Added account with authorization. Probable Cause Indicates the specified new account has been created. Recommended Action No action is required.
SEC-1184 Recommended Action Severity 75 Retry the command with a valid value. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. ERROR SEC-1184 Message , [SEC-1184], ,, INFO, , configuration change, action , server ID .
75 SEC-1187 SEC-1187 Message , [SEC-1187], ,, INFO, , Security violation: Unauthorized switch tries to join fabric. Probable Cause Indicates a switch connection control (SCC) security violation was reported. The specified unauthorized switch attempts to join the fabric. Recommended Action Check the switch connection control policy (SCC) policy to verify the switches allowed in the fabric.
SEC-1190 75 SEC-1190 Message , [SEC-1190], ,, INFO, , Security violation: Unauthorized host with IP address tries to do SNMP read operation. Probable Cause Indicates an SNMP security violation was reported. The specified unauthorized host attempted to perform a read SNMP operation. Recommended Action Check the RSNMP policy to verify the hosts allowed access to the fabric through SNMP read operations are included in the RSNMP policy.
75 SEC-1194 Probable Cause Indicates a specified login security violation was reported. The incorrect password was used while trying to log in through the specified connection method; the login failed. Recommended Action The error message lists the violating IP address. Verify that this IP address is being used by a valid switch admin. Use the correct password.
SEC-1197 Severity 75 WARNING SEC-1197 Message , [SEC-1197], ,, INFO, , Changed account . Probable Cause Indicates the specified account has changed. Recommended Action No action is required. Severity INFO SEC-1198 Message , [SEC-1198], ,, INFO, , Security violation: Unauthorized host with IP address tries to establish API connection.
75 SEC-1201 Probable Cause Indicates a management server (MS) forward security violation was reported. A management server command was forwarded from a non-primary fabric configuration server (FCS) switch. Recommended Action Check the MS policy and verify that the connection is allowed. If the connection is allowed but not specified, enable the connection in the MS policy.
SEC-1250 Severity 75 INFO SEC-1250 Message , [SEC-1250], ,, WARNING, , DCC enforcement API failed: err=, key= Probable Cause Indicates an internal error caused the DCC policy enforcement to fail. Recommended Action Retry the failed security command. Severity If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider.
75 SEC-1301 Probable Cause Indicates the switch is set up with VC-encoded mode. Recommended Action Turn off VC-encoded mode before enabling security. Severity INFO SEC-1301 Message , [SEC-1301], ,, INFO, , This switch is in interop mode. Security is not supported. Probable Cause Indicates the switch is interop-mode enabled. Recommended Action Disable interop-mode using the interopMode command before enabling the Secure Fabric OS feature.
SEC-1304 75 SEC-1304 Message , [SEC-1304], ,, INFO, , This switch has no security license. Probable Cause Indicates there has been a corruption during the distribution of the security database. This can only occur when the primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence.
75 SEC-1307 SEC-1307 Message , [SEC-1307], ,, INFO, , Got response from server . Probable Cause Indicates that after some servers timed out, the specified remote authentication dial-in user service (RADIUS/LDAP) server responded to a switch request.
SEC-1311 Severity 75 INFO SEC-1311 Message , [SEC-1311], ,, ERROR, , Security mode cannot be enabled because one or more of the password policies is not set to default value. Probable Cause Indicates the security enable failed on the fabric because one or more switches in the fabric have password policies that are not set to the default value. Recommended Action Verify the security event was planned.
75 SEC-1315 Probable Cause Indicates the call to the EM module to retrieve the IP address failed. Recommended Action Reboot the system to fix this error. If the problem persists contact your switch service provider.
SEC-1318 75 SEC-1318 Message , [SEC-1318], ,, INFO, , Transaction rejected due to inconsistent fabric Probable Cause Indicates that some domains detected an inconsistent fabric. Recommended Action Resolve the policy conflict, if there is one, then wait for the fabric to stabilize. Retry the distribution.
75 SEC-1322 Severity ERROR SEC-1322 Message , [SEC-1322], ,, WARNING, , Some DCC policy is too large, distribution cancelled Probable Cause Indicates this fabric is not able to support a device connection control (DCC) policy with more than 256 ports. Recommended Action Reconfigure any policy that includes more than 256 ports in its member list, then save the policy configuration changes.
SEC-1326 Recommended Action Severity 75 No action is required unless the switch must remain in the fabric. If the switch must remain in the fabric, add the switch world wide name (WWN) to the SCC policy, then attempt to join the switch with the fabric. ERROR SEC-1326 Message , [SEC-1326], ,, INFO, , Event: fddcfg --fabwideset, Status: success, Info: Fabric wide configuration set to .
75 SEC-1329 SEC-1329 Message , [SEC-1329], ,, ERROR, , IPFilter enforcement: Failed to enforce ipfilter policy of type because of . Probable Cause Indicates the IP filter policy enforcement failed due to internal system failure. Recommended Action Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider.
SEC-1333 Recommended Action Severity 75 Remove either the FCS from the fabric-wide policy, or remove 5.3 and 5.2 switches from the fabric, or set the fabric-wide mode for FCS as Strict. ERROR SEC-1333 Message , [SEC-1333], ,, ERROR, , command failed. There are VF enabled switches in fabric. db(s) distribution is blocked.
75 SEC-3037 SEC-3037 Message , [SEC-3037], , AUDIT, INFO, , Event: ipfilter, Status: success, Info: ipfilter policy activated. Probable Cause Indicates that that the specified IP filter policy has been activated. Recommended Action Verify that the security event was planned. If the security event was planned, no action is required. If the security event was not planned, take appropriate action as defined by your enterprise security policy.
SEC-3051 Recommended Action Severity 75 Verify the security event was planned. If the security event was planned, no action is required. If the security event was not planned, take appropriate action as defined by your enterprise security policy. INFO SEC-3051 Message , [SEC-3051], , AUDIT, INFO, , The license key is . Probable Cause Indicates that a license key is added or removed. Recommended Action No action is required.
75 466 SEC-3051 Fabric OS Message Reference 53-1001157-01
Chapter SNMP System Messages 76 SNMP-1001 Message , [SNMP-1001], ,, ERROR, , SNMP service is not available . Probable Cause Indicates the simple network management protocol (SNMP) service could not be started because of the specified Reason. You will not be able to query the switch through SNMP. Recommended Action Verify the IP address for the Ethernet and Fibre Channel interface is set correctly.
76 SNMP-1004 SNMP-1004 Message , [SNMP-1004], , FFDC, ERROR, , Incorrect SNMP configuration. Probable Cause Indicates the simple network management protocol (SNMP) configuration is incorrect and the SNMP service will not work correctly. Recommended Action Change the SNMP configuration back to the default.
SNMP-1008 Severity 76 INFO SNMP-1008 Message , [SNMP-1008], ,, INFO, , The last device change happened at: . Probable Cause Indicates the last device change time. Recommended Action Execute the nsshow to view the current device status.
76 470 SNMP-1008 Fabric OS Message Reference 53-1001157-01
Chapter SPC System Messages 77 SPC-1001 Message , [SPC-1001], ,, INFO, , , Cryptographic operation enabled. Probable Cause Indicates the cryptographic operation is enabled on an encryption engine. Recommended Action No action is required. Severity INFO SPC-1002 Message , [SPC-1002], ,, INFO, , , Cryptographic operation disabled.
77 SPC-2001 SPC-2001 Message , [SPC-2001], ,, ERROR, , , : Crypto error asserted by Vader/OB1 0x%x. Probable Cause Indicates the Crypto error asserted by FPGA. Recommended Action No action is required.
SPC-2005 77 SPC-2005 Message , [SPC-2005], ,, INFO, , , : FPGA firmware download success: 0x%x. Probable Cause Indicates the FPGA download was successful. Recommended Action No action is required. Severity INFO SPC-2006 Message , [SPC-2006], ,, ERROR, , , : Crypto post tests failed: 0x%x.
77 SPC-2009 SPC-2009 Message , [SPC-2009], ,, CRITICAL, , , : Tamper event: User zeroization. Probable Cause Indicates the Tamper event triggered due to a user zeroize request. Recommended Action EE is zeroized. User needs to run initEE and regEE.
SPC-3001 77 SPC-3001 Message , [SPC-3001], ,, ERROR, , , : No input KEK for DEK inject, DEK: , KEK: . Probable Cause Indicates the wrapping KEK for the DEK to be injected does not exist within the EE Crypto Module.
77 SPC-3005 Probable Cause Indicates the output wrapping KEK for the DEK to be created does not exist within the EE Crypto Module. Recommended Action For opaque key vaults such as RKM, recover the missing Master Key to current or alternate position.
SPC-3007 77 SPC-3007 Message Probable Cause , [SPC-3007], ,, ERROR, , , : DEK create error: , info: .
77 SPC-3010 SPC-3010 Message , [SPC-3010], ,, WARNING, , , : SEK integrity failure during initialization. Probable Cause Indicates the Crypto Module internal Secret Encryption Key has been corrupted or has not been initialized. Recommended Action Run initEE and regEE.
SPC-3014 Recommended Action Severity 77 Contact technical support. ERROR SPC-3014 Message , [SPC-3014], ,, ERROR, , , : RNG compare failure: successive values match. Probable Cause Indicates the Crypto Module internal random number generator failed. Recommended Action Contact technical support.
77 480 SPC-3015 Fabric OS Message Reference 53-1001157-01
Chapter SPM System Messages 78 SPM-1001 Message , [SPM-1001], ,, ERROR, , Init fails: . Probable Cause Indicates SPM failed to initialize. Recommended Action Check system resources and reboot switch. Severity ERROR SPM-1002 Message , [SPM-1002], ,, WARNING, , Generic SPM Warning: . Probable Cause Depends on reason. Recommended Action Issue supportsave to gather information.
78 SPM-1005 Recommended Action Severity No action is required. INFO SPM-1005 Message , [SPM-1005], ,, INFO, , Set EE Control slot action . Probable Cause User configured. Recommended Action No action is required. Severity INFO SPM-1006 Message , [SPM-1006], ,, INFO, , Registered Certificate of type . Probable Cause User configured. Recommended Action No action is required.
SPM-1009 Recommended Action Severity 78 No action is required. INFO SPM-1009 Message , [SPM-1009], ,, ERROR, , Certificate is missing. Probable Cause User configured. Recommended Action Run cryptocfg --initnode. Severity ERROR SPM-1010 Message , [SPM-1010], ,, ERROR, , Key Vault Certificate is missing. Probable Cause User configured. Recommended Action Deregister and register this key vault.
78 484 SPM-1010 Fabric OS Message Reference 53-1001157-01
Chapter SS System Messages 79 SS-1000 Message , [SS-1000], ,, INFO, , supportSave has uploaded support information to the host with IP address . Probable Cause Indicates the supportSave command was used to transfer support information to a remote location. Recommended Action No action is required.
79 SS-1003 SS-1003 Message , [SS-1003], ,, WARNING, , supportSave's operation to USB storage device aborted. Probable Cause Indicates a USB operation error occurred during execution of the supportSave command. Complete error information cannot always be displayed in this message due to possible errors in subcommands being executed by the supportSave command. Recommended Action Run the usbstorage command to check the USB storage device settings.
Chapter SULB System Messages 80 SULB-1001 Message , [SULB-1001], , AUDIT, WARNING, , Firmwaredownload command has started. Probable Cause Indicates the firmwareDownload command has been entered. This process should take approximately 17 minutes. The process is set to time out after 30 minutes. Recommended Action Do not fail over or power down the system during firmware upgrade. Allow the firmwareDownload command to continue without disruption.
80 SULB-1004 SULB-1004 Message , [SULB-1004], INFO, FIRMWARE, , , , Firmwarecommit has completed. Probable Cause Indicates the FirmwareCommit command is executed. Recommended Action No action is required. Run the firmwareDownloadStatus command for more information. Severity INFO SULB-1005 Message , [SULB-1005], ,, INFO, , Current Active CP is preparing to failover.
SULB-1008 80 SULB-1008 Message , [SULB-1008], ,, INFO, , Standby CP booted successfully with new firmware. Probable Cause Indicates the standby CP has rebooted successfully. Recommended Action No action is required. The firmwareDownload command is progressing as expected. Severity Run the firmwareDownloadStatus command for more information.
80 SULB-1009 TABLE 6 490 Status Messages and Status Codes Status Message Status Code “firmwareCommit operation failed due to IPC error.” 0x55 "Unable to check the firmware version on Standby CP due to IPC error." 0x56 “Unable to restore the original firmware due to Standby CP timeout.” 0x57 "Standby CP failed to reboot and was not responding." 0x58 "Unable to check the firmware version on Standby CP due to IPC error.
SULB-1009 TABLE 6 Status Messages and Status Codes Status Message Status Code "The original firmware has been restored successfully on Standby CP." 0x7e "Unable to restore the original firmware on Standby CP." 0x7f "Standby CP reboots." 0x80 "Standby CP failed to reboot." 0x81 "Standby CP booted up with new firmware." 0x82 "Standby CP failed to boot up with new firmware." 0x83 “There was an unexpected reboot during firmwareDownload. The command is aborted.
80 SULB-1009 TABLE 6 Status Messages and Status Codes Status Message Status Code “firmwareRestore is entered. System will reboot and a firmwareCommit operation will start upon boot up.” 0xa8 "Switch is relocating the AP image." 0xa9 "The AP image is relocated successfully." 0xaa "Switch reboots during relocating the AP image. The operation will be restarted." 0xab “Blade failed to reboot with the original image. firmwareRestore command failed.
SULB-1009 TABLE 7 80 Error Messages and Error Codes Error Message Error Code “firmwareDownload timed out.” 0x23 "Our of disk space." 0x24 “Primary filesystem is inconsistent. Run firmwareRestore to restore the original firmware, or contact your service provider for recovery.” 0x25 "The post-install script failed." 0x26 "Unexpected reboot." 0x27 "Primary kernel partition is inconsistent. Please contact your service provider for recovery." 0x28 "The pre-install script failed.
80 SULB-1009 0x24 - out of disk space. This error may occur because some coredump files have not been removed from the filesystem and are using up disk space. Remove these coredump files using the supportSave command before proceeding. 0x29 - The pre-install script failed. This error may be caused by an unsupported blade type in the chassis. Remove or power off the unsupported blades before proceeding. Another possible cause may be an invalid chassisConfig option setting.
SULB-1010 80 In a director-class switch, when firmwareDownload fails, the two CPs may end up with different versions of firmware and they may not gain high-availability (HA) sync. In that case, run firmwareDownload single mode (-s) to upgrade the firmware on the standby CP to the same version as the active CP. Then retry firmwareDownload to download the desired version of firmware onto the CPs. Refer to the Fabric OS Administrator’s Guide for troubleshooting information.
80 SULB-1018 Severity ERROR SULB-1018 Message , [SULB-1018], , AUDIT, ERROR, , Firmwaredownload timed out in slot . Probable Cause Indicates there may be an error caused by the blade initialization issue after the new firmware is downloaded and the blade is rebooted. The error may also be caused by the internal Ethernet issue or by the persistent storage failure. Recommended Action Run the slotShow command.
SULB-1022 80 SULB-1022 Message , [SULB-1022], ,, WARNING, , The blade in slot has rebooted successfully with new firmware. Probable Cause Indicates that the blade in the specified slot has rebooted with new firmware. This is a normal step in the firmwareDownload process. Recommended Action Run the firmwareDownloadStatus command to monitor the firmwareDownload progress.
80 SULB-1025 SULB-1025 Message , [SULB-1025], ,, WARNING, , The blade in slot will reboot with the new firmware. Probable Cause Indicates new firmware has been downloaded to the specified AP blade and that the AP blade will reboot to activate it. Recommended Action Wait for the blade to reboot.
SULB-1032 Recommended Action Severity 80 Wait for the operation to complete. WARNING SULB-1032 Message , [SULB-1032], , AUDIT, WARNING, , Relocating an internal firmware image on the CP. Probable Cause Indicates the switch has started a firmware download to the co-CPU. Recommended Action Wait for the operation to complete.
80 SULB-1036 Probable Cause Indicates an error has occurred during the relocation of the internal image. The error may be caused by inconsistent internal firmware image. It may also be caused by the internal Ethernet or persistent storage hardware failure. Recommended Action Reset the switch. This will cause the internal image to be relocated again. If the problem persists, contact your switch service provider.
Chapter SWCH System Messages 81 SWCH-1001 Message , [SWCH-1001], ,, ERROR, , Switch is not in ready state - Switch enable failed switch status= 0x, c_flags = 0x. Probable Cause Indicates the switch is enabled before it is ready. Recommended Action If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider.
81 SWCH-1004 SWCH-1004 Message , [SWCH-1004], ,, ERROR, , Blade attach failed during recovery, disabling slot = . Probable Cause Indicates a blade has failed during failover or recovery. Recommended Action On a Brocade 24000 or 48000 switch, run the slotPowerOff command and then the slotPowerOn command.
SWCH-1008 Recommended Action 81 Based on the disable reason displayed, proper corrective action may to be required to restore the port. If insufficient frame buffers is the disable reason, reduce the distance or speed settings for the port to reduce the buffer requirement of the link. Alternatively, one or more ports in the port group must be disabled to make more buffers available for the link. Please refer to the Fabric OS Administrator’s Guide for more information about buffers.
81 SWCH-1011 Severity WARNING SWCH-1011 Message , [SWCH-1011], ,, WARNING, , HA state out of sync: Standby CP (ver = ) does not support Trunk Area functionality. (active ver = , Trunk Area enabled on switch = <'1' if Trunk Area ports exist; Otherwise '0'>). Probable Cause Indicates the standby control processor (CP) does not support Trunk Area functionality, but the switch has some ports with Trunk Area enabled.
Chapter SYSC System Messages 82 SYSC-1001 Message , [SYSC-1001], , FFDC, CRITICAL, , Failed to run :. Probable Cause Indicates that during the boot sequence, one of the programs would not run on the system. Recommended Action If the message is reported during a reboot after new firmware has been loaded, try reloading the firmware using the firmwareDownload command.
82 SYSC-1004 It could also indicate that the current option number could not be read from the chassis option storage device (the world wide name (WWN) card). This message occurs only on the Brocade 24000 and 48000. Recommended Action Severity As indicated in the message, run the chassisConfig command to change to one that is valid on this platform running this firmware. Note that the chassisConfig option 1 should be valid for all platforms running any valid firmware.
Chapter SYSM System Messages 83 SYSM-1001 Message , [SYSM-1001], , FFDC, CRITICAL, , No memory. Probable Cause Indicates the switch has run out of system memory. Recommended Action Run the memShow command to view the switch memory usage. Reboot or power cycle the switch. Run supportFtp as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider.
83 SYSM-1004 SYSM-1004 Message , [SYSM-1004], ,, ERROR, , Failed to retrieve current chassis configuration option, ret= Probable Cause Indicates there was a failure to read configuration data from the WWN card. Recommended Action Verify that the world wide name (WWN) card is present and operational and that the affected control processor (CP) is properly seated in its slot.
Chapter TAPE System Messages 84 TAPE-1001 Message , [TAPE-1001], , FFDC, INFO, , Key acquisition for . Probable Cause Indicates that the key acquisition for the pool or the container has begun or is complete. Recommended Action No action is required.
84 510 TAPE-1001 Fabric OS Message Reference 53-1001157-01
Chapter TRCE System Messages 85 TRCE-1001 Message Probable Cause , [TRCE-1001], ,, WARNING, , Trace dump available< optional slot indicating on which slot the dump occurs >! (reason: ) Indicates that trace dump files have been generated on the switch or the indicated slot.
85 TRCE-1004 Recommended Action Severity If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. ERROR TRCE-1004 Message , [TRCE-1004], ,, WARNING, , Trace dump< optional slot indicating on which slot the dump occurs > was not transferred because trace auto-FTP disabled.
TRCE-1007 85 TRCE-1007 Message , [TRCE-1007], ,, ERROR, , Notification of this CP has failed. Parameters temporarily out of synch with other CP. Probable Cause Indicates that the active CP is unable to alert the standby CP of a change in trace status. This message is only applicable to the Brocade 24000, and 48000. Recommended Action This message is often transitory. Wait a few minutes and try the command again.
85 TRCE-1011 Probable Cause Indicates that the trace daemon (traced), used for transferring trace files, failed to start. The trace capability within the switch is unaffected. The traced facility is normally restarted automatically by the system after a brief delay. Recommended Action If the message persists, reboot the CP (dual-CP system) or restart the switch.
Chapter TRCK System Messages 86 TRCK-1001 Message , [TRCK-1001], ,, INFO, , Successful login by user . Probable Cause Indicates the track change feature recorded a successful login. Recommended Action No action is required. Severity INFO TRCK-1002 Message , [TRCK-1002], ,, INFO, , Unsuccessful login by user . Probable Cause Indicates the track change feature recorded a failed login.
86 TRCK-1005 Probable Cause Indicates the track change feature recorded a configuration change for the switch. The track change feature records any change to the configuration file in nonvolatile memory, including a configDownload. This message is not generated for a configUpload. All configuration changes occur through the PDM server, so the PDMIPC is the only task possible. Recommended Action No action is required. Run the configShow command to view the configuration file.
Chapter TS System Messages 87 TS-1001 Message Probable Cause , [TS-1001], ,, WARNING, , NTP Query failed: . Indicates a network time protocol (NTP) query to the configured external clock server failed. Local clock time on the principal or primary fabric configuration server (FCS) switch is used for fabric synchronization. This might be logged during temporary operational issues such as IP network connection issues to the external clock server.
87 TS-1006 TS-1006 Message Probable Cause , [TS-1006], ,, INFO, , . Indicates a time service event is occurring or has failed. The message might be one of the following: • Init failed. Time Service exiting Probable Cause: Initialization error, Time Server exits.
TS-1008 Fabric OS Message Reference 53-1001157-01 87 519
87 520 TS-1008 Fabric OS Message Reference 53-1001157-01
Chapter UCST System Messages 88 UCST-1003 Message , [UCST-1003], ,, INFO, , Duplicate Path to Domain , Output Port = , PDB pointer = 0x Probable Cause Indicates that duplicate paths were reported to the specified domain from the specified output port. The path database (PDB) pointer is the address of the path database and provides debugging information. Recommended Action No action is required.
88 UCST-1025 UCST-1025 Message , [UCST-1025], ,, INFO, , In-order delivery option has been enabled with Lossless-DLS option. Probable Cause Indicates the IOD option has been enabled for the switch. This option guarantees in-order delivery of frames during topology changes. Recommended Action No action is required. Severity INFO UCST-1026 Message , [UCST-1026], ,, INFO, , LossLess-DLS option has been enabled.
Chapter UPTH System Messages 89 UPTH-1001 Message , [UPTH-1001], ,, WARNING, , No minimum cost path in candidate list Probable Cause Indicates the specified switch is unreachable because no minimum cost path (FSPF UPATH) exists in the candidate list (domain ID list). Recommended Action No action is required. This will end the current SPF computation.
89 524 UPTH-1001 Fabric OS Message Reference 53-1001157-01
Chapter WEBD System Messages 90 WEBD-1001 Message , [WEBD-1001], ,, WARNING, , Missing or Invalid Certificate file -- HTTPS is configured but could not be started. Probable Cause Indicates the SSL certificate file is either invalid or absent. Recommended Action Install a valid key file.
90 WEBD-1006 Recommended Action Severity No action is required. WARNING WEBD-1006 Message , [WEBD-1006], ,, INFO, , HTTP server restarted due to logfile truncation. Probable Cause Indicates the size of the HTTP log file exceeded the maximum limit. Recommended Action No action is required. Severity INFO WEBD-1007 Message , [WEBD-1007], ,, INFO, , HTTP server will be restarted due to change of IP Address.
Chapter ZOLB System Messages 91 ZOLB-1001 Message , [ZOLB-1001], ,, ERROR, , ZONELIB Probable Cause Indicates there was an internal timeout on the inter process communication (IPC) between the name server (NS) and the zoning modules. This usually indicates that the system was busy. Recommended Action This message generates core dump files of the related modules (zoned, nsd, rcsd).
91 528 ZOLB-1001 Fabric OS Message Reference 53-1001157-01
Chapter ZONE System Messages 92 ZONE-1002 Message , [ZONE-1002], ,, WARNING, , WWN zoneTypeCheck or zoneGroupCheck warning() at port(). Probable Cause Indicates a zone filter or zone group check failure occurred. The frame filter logic reported a failure when creating or adding zone groups during port login (PLOGI) trap processing.
92 ZONE-1005 In session-based zoning, the zone enforcement is checked by the software. In hardware-enforced zoning, zone or alias members are defined using exclusively or using WWNs exclusively: that is, using one method or the other to define all objects in the zoning database. If the devices on the port are defined by a mixture of port IDs and WWNs, the zone enforcement is session based.
ZONE-1007 92 ZONE-1007 Message , [ZONE-1007], ,, INFO, , Ioctl() in () at port () returns code () and reason string (). Probable Cause Indicates that frame filter logic reported a failure during one of the IOCTL calls. The IOCTL call from which the failure is reported is listed as part of the error message.
92 ZONE-1013 Recommended Action Severity Check the device connection. WARNING ZONE-1013 Message , [ZONE-1013], ,, WARNING, , Quick Loop not supported. Probable Cause Indicates the QuickLoop feature is not supported in the current code release. If the QuickLoop zoning configuration is enabled on the switch, it will not be supported. Recommended Action Edit the zone database to remove the QuickLoop zoning definition in the effective configuration.
ZONE-1018 92 Probable Cause Indicates the fabric assist (FA) zoning configuration has more than one initiator. The probable cause is incorrect entries in the FA zoning configuration. Recommended Action Edit the zone database to ensure that only one initiator is set for each FA zone configuration. Severity ERROR ZONE-1018 Message Probable Cause , [ZONE-1018], ,, ERROR, , Incorrect zoning enforcement type() at port().
92 ZONE-1022 ZONE-1022 Message , [ZONE-1022], ,, INFO, , The effective configuration has changed to . Probable Cause Indicates the effective zone configuration has changed to the name displayed. Recommended Action Verify this zone configuration change was done on purpose. If the new effective zone configuration is correct, no action is necessary.
ZONE-1027 92 ZONE-1027 Message Probable Cause , [ZONE-1027], ,, INFO, , Zoning transaction aborted . . Indicates the zoning transaction was aborted due to a variety of potential errors. The error reason variable can be one of the following: • • • • • • • • Recommended Action Severity Zone Merge Received: The fabric is in the process of merging two zone databases.
92 ZONE-1030 If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING ZONE-1030 Message , [ZONE-1030], ,, WARNING, , Converting the zone db for PID format change failed. Probable Cause Indicates the current zone database could not be converted to reflect the PID format change. Most likely this is caused by the size of the zone database.
ZONE-1034 92 Probable Cause Indicates the specified domain has the lowest memory available for the zone database in the fabric. The zone database must be smaller than the memory available on this domain. Recommended Action Reduce the size of the zone database and retry the operation. Severity ERROR ZONE-1034 Message , [ZONE-1034], ,, WARNING, , A new zone database file was successfully created for the switch.
92 ZONE-1037 ZONE-1037 Message , [ZONE-1037], ,, ERROR, , Unable to examine : error message . Probable Cause Indicates the Fabric OS cannot examine the zone configuration file. Typically the zone configuration is too large for the memory available on the switch. Recommended Action Reduce the size of the zone database and retry the operation.
ZONE-1041 Severity 92 INFO ZONE-1041 Message , [ZONE-1041], ,, WARNING, , Unstable link detected during merge at port (). Probable Cause Indicates a possible unstable link or faulty cable. Recommended Action Check the SFP and cable at the specified port and verify that they are not faulty. Replace the SFP and cable as necessary.
92 ZONE-1045 ZONE-1045 Message , [ZONE-1045], ,, INFO, , The Default Zone access mode is already set to No Access. Probable Cause Indicates that the Default Zone access mode is already set to No Access. Recommended Action No action is required. Severity INFO ZONE-1046 Message , [ZONE-1046], ,, INFO, , The Default Zone access mode is already set to All Access.
ZONE-1049 92 ZONE-1049 Message , [ZONE-1049], ,, ERROR, , ZONE AD-DefZone conflict detected while system initialization. Probable Cause Indicates that there is an AD-DefZone conflict. Recommended Action Check and resolve the default zone mismatch issue. Severity ERROR ZONE-1050 Message , [ZONE-1050], ,, INFO, , The Interop Safe Zoning mode is set to Enabled.
92 ZONE-1053 ZONE-1053 Message , [ZONE-1053], ,, INFO, , The Default Zone state is set to Disabled. Probable Cause Indicates the Interop Default Zone attribute state is disabled. Recommended Action Verify if the Interop Default Zone attribute state change was done on purpose.
Section II Audit Log Messages This section provides the Audit messages, including: • AUDIT AG System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • AUDIT AUTH System Messages. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • AUDIT CONF System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • AUDIT FCIP System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • AUDIT FICU System Messages .
Chapter AUDIT AG System Messages 89 AG-1029 Message AUDIT, , [AG-1029], INFO, CFG, , , , F_Port to N_Port mapping has been updated for N_Port . Probable Cause Indicates that the F_Ports mapped to an N_Port have changed and the config file has been updated. Recommended Action No action is required.
89 546 AG-1029 Fabric OS Message Reference 53-1001157-01
Chapter AUDIT AUTH System Messages 90 AUTH-3001 Message AUDIT, , [AUTH-3001], INFO, SECURITY, , , , Event: , Status: success, Info: type has been changed from [] to []. Probable Cause Indicates that an authentication configuration value was set to a specified value. The data type is “authentication type”, “DH group type”, “Hash type”, or “policy type”. Recommended Action No action is required.
90 AUTH-3004 AUTH-3004 Message AUDIT, , [AUTH-3004], INFO, SECURITY, , , , Event: , Status: failed, Info: Neighboring switch has a conflicting authentication policy; Port disabled. Probable Cause The specified E_Port was disabled because the neighboring switch rejected the authentication negotiation, and the local switch has a strict switch authentication policy.
AUTH-3007 90 AUTH-3007 Message Probable Cause AUDIT, , [AUTH-3007], INFO, SECURITY, , , , Event: , Status: failed, Info: Port disabled due to receiving an authentication reject with code '' and explanation ''. Indicates that the specified port was disabled due to receiving an authentication reject response from the connected switch/device.
90 550 AUTH-3008 Fabric OS Message Reference 53-1001157-01
Chapter AUDIT CONF System Messages 91 CONF-1000 Message AUDIT, , [CONF-1000], INFO, CFG, , , , configDownload completed successfully. . Probable Cause The configDownload process was initiated and completed successfully. The message string describes the class of configuration parameters that were downloaded. If admin domain (AD) is enabled, the AD number is specified in the description.
91 552 CONF-1022 Fabric OS Message Reference 53-1001157-01
Chapter AUDIT FCIP System Messages 92 FCIP-1002 Message AUDIT, , [FCIP-1002], INFO, CFG, , , , An IPsec/IKE policy was added. Probable Cause Indicates that an IPsec/IKE policy was added and the config file was updated. Recommended Action No action is required. Severity INFO FCIP-1003 Message AUDIT, , [FCIP-1003], INFO, CFG, , , , An IPsec/IKE policy was deleted.
92 554 FCIP-1003 Fabric OS Message Reference 53-1001157-01
Chapter AUDIT FICU System Messages 93 FICU-1011 Message AUDIT, , [FICU-1011], INFO, CFG, , , , FMS mode has been enabled. Probable Cause Indicates the FICON Management server mode has been enabled. Recommended Action No action is required. Severity INFO FICU-1012 Message AUDIT, , [FICU-1012], INFO, CFG, , , , FMS mode has been disabled.
93 556 FICU-1012 Fabric OS Message Reference 53-1001157-01
Chapter AUDIT FW System Messages 94 FW-3001 Message AUDIT, , [FW-3001], INFO, , , , Event: , Status: success, Info: Probable Cause Indicates that Port Fencing was enabled/disabled successfully. Recommended Action No action is required.
94 558 FW-3001 Fabric OS Message Reference 53-1001157-01
Chapter AUDIT HTTP System Messages 95 HTTP-1002 Message AUDIT, , [HTTP-1002], INFO, ZONE, , , , Zoning transaction initiated by User: , Role: completed successfully. Probable Cause Indicates that the zoning database has been changed. Recommended Action Verify that the event was planned. If the event was planned, no action is required.
95 560 HTTP-1003 Fabric OS Message Reference 53-1001157-01
Chapter AUDIT IPAD System Messages 96 IPAD-1002 Message AUDIT, , [IPAD-1002], INFO, CFG, , , , Switchname has been successfully changed to . Probable Cause Indicates that a change with the switch name has occured. Recommended Action No action is required.
96 562 IPAD-1002 Fabric OS Message Reference 53-1001157-01
Chapter AUDIT PORT System Messages 97 PORT-1006 Message AUDIT, , [PORT-1006], INFO, CFG, , , , Configuration changed for port (ID: ) in No_Module or No_Light state. Probable Cause Indicates the configuration changes were made to an offline port in No_Module or No_Light state. Recommended Action No action is required.
97 PORT-1009 Probable Cause Indicates a GigE port has been disabled. Recommended Action No action is required.
Chapter AUDIT SEC System Messages 98 SEC-3001 Message AUDIT, , [SEC-3001], INFO, SECURITY, , , , Event: , Status: success, Info: Security mode on the fabric. Probable Cause Indicates the security mode of the fabric was either enabled or disabled. Recommended Action Verify the security mode change was planned. If the security mode change was planned, no action is required.
98 SEC-3004 Recommended Action Severity Verify the new policy creation was planned. If the new policy creation was planned, no action is required. If the new policy creation was not planned, take appropriate action as defined by your enterprise security policy. INFO SEC-3004 Message AUDIT, , [SEC-3004], INFO, SECURITY, , , , Event: , Status: success, Info: Created policy.
SEC-3007 Recommended Action Severity 98 Verify the removal of members to the policy was planned. If the removal of members was planned, no action is required. If the removal of members was not planned, take appropriate action as defined by your enterprise security policy. INFO SEC-3007 Message AUDIT, , [SEC-3007], INFO, SECURITY, , , , Event: , Status: success, Info: Deleted policy .
98 SEC-3010 SEC-3010 Message AUDIT, , [SEC-3010], INFO, SECURITY, , , , Event: , Status: success, Info: Reset [] security stat(s). Probable Cause Indicates a user has reset all the security statistics. Recommended Action Verify the security statistics were intentionally reset. If the security statistics were intentionally reset, no action is required.
SEC-3014 Recommended Action Severity 98 Verify the security version stamp was intentionally reset. If the security event was planned, no action is required. If the security version stamp was not intentionally reset, take appropriate action as defined by your enterprise security policy.
98 SEC-3017 Severity INFO SEC-3017 Message AUDIT, , [SEC-3017], INFO, SECURITY, , , , Event: , Status: success, Info: . Probable Cause Indicates a user has changed the remote authentication dial-in user service (RADIUS) configuration. Recommended Action Verify the RADIUS configuration was intentionally changed. If the RADIUS configuration was intentionally changed, no action is required.
SEC-3021 98 Probable Cause Indicates a successful login occurred. An IP address is displayed when the login occurs over a remote connection. Recommended Action Verify the security event was planned. If the security event was planned, no action is required. If the security event was not planned, take appropriate action as defined by your enterprise security policy.
98 SEC-3024 SEC-3024 Message AUDIT, , [SEC-3024], INFO, SECURITY, , , , Event: , Status: success, Info: User account [], password changed. Probable Cause Indicates the user's password was changed. Recommended Action Verify the security event was planned. If the security event was planned, no action is required. If the security event was not planned, take appropriate action as defined by your enterprise security policy.
SEC-3028 Recommended Action Severity 98 Verify the security event was planned. If the security event was planned, no action is required. If the security event was not planned, take appropriate action as defined by your enterprise security policy. INFO SEC-3028 Message AUDIT, , [SEC-3028], INFO, SECURITY, , , , Event: , Status: success, Info: User account [] deleted.
98 SEC-3031 SEC-3031 Message AUDIT, , [SEC-3031], INFO, SECURITY, , , , Event: , Status: success, Info: Distributed db(s) to domains, dom-id(s). Probable Cause Indicates that the specified event has occurred. Recommended Action Verify the event was planned. If the event was planned, no action is required.
SEC-3035 Severity 98 INFO SEC-3035 Message AUDIT, , [SEC-3035], INFO, SECURITY, , , , Event: ipfilter, Status: success, Info: IP filter policy(ies) saved. Probable Cause Indicates the specified IP filter policies have been saved. Recommended Action Verify the security event was planned. If the security event was planned, no action is required.
98 SEC-3039 Probable Cause Indicates the specified IP filter policy failed to activate. Recommended Action Verify the security event was planned. If the security event was planned, no action is required. If the security event was not planned, take appropriate action as defined by your enterprise security policy.
SEC-3044 98 SEC-3044 Message AUDIT, , [SEC-3044], INFO, SECURITY, , , FIPS mode has been changed to . Probable Cause Indicates there was a change in the FIPS mode. Recommended Action Verify the security event was planned. If the security event was planned, no action is required. If the security event was not planned, take appropriate action as defined by your enterprise security policy.
98 SEC-3048 SEC-3048 Message AUDIT, , [SEC-3048], INFO, SECURITY, , , FIPS mode has been enabled in the system using force option. Probable Cause Indicates the system has been forced to FIPS mode. Recommended Action Verify the security event was planned. If the security event was planned, no action is required. If the security event was not planned, take appropriate action as defined by your enterprise security policy.
Chapter AUDIT SNMP System Messages 99 SNMP-1004 Message AUDIT, , [SNMP-1004], ERROR, CONFIGURATION, , , , Incorrect SNMP configuration. Probable Cause Indicates that the simple network management protocol (SNMP) configuration s incorrect and the SNMP service will not work correctly. Recommended Action Reset the SNMP configuration to default.
99 580 SNMP-1006 Fabric OS Message Reference 53-1001157-01
Chapter AUDIT SULB System Messages 100 SULB-1001 Message AUDIT, , [SULB-1001], WARNING, FIRMWARE, , , , Firmwaredownload command has started. Probable Cause Indicates the firmwareDownload command has been entered. This process should take approximately 17 minutes. The process is set to time out after 30 minutes. Recommended Action No action is required. Allow the firmwareDownload command to continue without disruption.
100 SULB-1004 SULB-1004 Message AUDIT, , [SULB-1004], INFO, FIRMWARE, , , , Firmwarecommit has completed. Probable Cause Indicates the FirmwareCommit command is executed. Recommended Action No action is required. Run the firmwareDownloadStatus command for more information. Severity INFO SULB-1009 Message Probable Cause AUDIT, , [SULB-1009], INFO, FIRMWARE, , , , Firmwaredownload command failed.
SULB-1009 TABLE 9 Status Messages and Status Codes Status Message Status Code “firmwareCommit operation failed due to IPC error.” 0x55 "Unable to check the firmware version on Standby CP due to IPC error." 0x56 “Unable to restore the original firmware due to Standby CP timeout.” 0x57 "Standby CP failed to reboot and was not responding." 0x58 "Unable to check the firmware version on Standby CP due to IPC error." 0x59 “Sanity check failed because firmwareDownload is already in progress.
100 SULB-1009 TABLE 9 584 Status Messages and Status Codes Status Message Status Code "The original firmware has been restored successfully on Standby CP." 0x7e "Unable to restore the original firmware on Standby CP." 0x7f "Standby CP reboots." 0x80 "Standby CP failed to reboot." 0x81 "Standby CP booted up with new firmware." 0x82 "Standby CP failed to boot up with new firmware." 0x83 “There was an unexpected reboot during firmwareDownload. The command is aborted.
SULB-1009 TABLE 9 100 Status Messages and Status Codes Status Message Status Code “firmwareRestore is entered. System will reboot and a firmwareCommit operation will start upon boot up.” 0xa8 "Switch is relocating the AP image." 0xa9 "The AP image is relocated successfully." 0xaa "Switch reboots during relocating the AP image. The operation will be restarted." 0xab “Blade failed to reboot with the original image. firmwareRestore command failed.
100 SULB-1009 TABLE 10 Error Messages and Error Codes Error Message Error Code “firmwareDownload timed out.” 0x23 "Our of disk space." 0x24 “Primary filesystem is inconsistent. Run firmwareRestore to restore the original firmware, or contact your service provider for recovery.” 0x25 "The post-install script failed." 0x26 "Unexpected reboot." 0x27 "Primary kernel partition is inconsistent. Please contact your service provider for recovery." 0x28 "The pre-install script failed.
SULB-1009 100 0x24 - out of disk space. This error may occur because some coredump files have not been removed from the filesystem and are using up disk space. Remove these coredump files using the supportSave command before proceeding. 0x29 - The pre-install script failed. This error may be caused by an unsupported blade type in the chassis. Remove or power off the unsupported blades before proceeding. Another possible cause may be an invalid chassisConfig option setting.
100 SULB-1010 In a director-class switch, when firmwareDownload fails, the two CPs may end up with different versions of firmware and they may not gain high-availability (HA) sync. In that case, run firmwareDownload single mode (-s) to upgrade the firmware on the standby CP to the same version as the active CP. Then retry firmwareDownload to download the desired version of firmware onto the CPs. Refer to the Fabric OS Administrator’s Guide for troubleshooting information.
SULB-1020 Recommended Action Severity 100 Run the slotShow command. If the blade is in a FAULTY state, run the slotPowerOff and slotPowerOn commands to trigger another firmwareDownload. If the blade is stuck in LOADING state, remove and re-insert the blade to trigger another firmwareDownload. If the problem persists, contact your switch service provider.
100 SULB-1024 Recommended Action Severity The firmwareCommit command will be started automatically after the blade boots up to repair the secondary partition. If at the end of firmwareCommit, the blade firmware version is still inconsistent with the active CP firmware, firmwareDownload will automatically be restarted on the blade. Run the firmwareDownloadStatus command to monitor the progress. If the problem persists, contact your switch service provider.
SULB-1031 Recommended Action Severity 100 The firmwareDownload command will continue after the switch has rebooted. Run the firmwareDownloadStatus command to monitor progress. If the problem persists, contact your switch service provider. WARNING SULB-1031 Message AUDIT, , [SULB-1032], WARNING, FIRMWARE, , , , Relocating an internal firmware image on the CP.
100 SULB-1035 Recommended Action Severity Reboot the switch. This will cause the internal image to be relocated again. Use the firmwareDownloadStatus command to monitor the progress. If the problem persists, contact your switch service provider. ERROR SULB-1035 Message AUDIT, , [SULB-1035], ERROR, FIRMWARE, , , , An error has occurred relocation of the internal image.
Chapter AUDIT SWCH System Messages 101 SWCH-1012 Message AUDIT, , [SWCH-1012], INFO, CFG, , , , Trunk Area () has been enabled for one or more ports. Probable Cause Indicates a Trunk Area has been enabled for one or more ports and the config file has been updated. Recommended Action No action is required.
101 SWCH-1014 594 Fabric OS Message Reference 53-1001157-01
Chapter AUDIT UCST System Messages 102 UCST-1021 Message AUDIT, , [UCST-1021], INFO, CFG, , , , In-order delivery option has been enabled. Probable Cause Indicates the IOD option has been enabled for the switch. This option guarantees in-order delivery of frames during topology changes. Recommended Action No action is required.
102 UCST-1024 UCST-1024 Message AUDIT, , [UCST-1024], INFO, CFG, , , , Dynamic Load Sharing option has been disabled. Probable Cause Indicates the DLS option has been disabled for the switch. Recommended Action No action is required. Severity INFO UCST-1025 Message AUDIT, , [UCST-1025], INFO, CFG, , , , In-order delivery option has been enabled with Lossless-DLS option.
UCST-1027 Severity 102 INFO Fabric OS Message Reference 53-1001157-01 597
102 UCST-1027 598 Fabric OS Message Reference 53-1001157-01
Chapter AUDIT ZONE System Messages 103 ZONE-3001 Message Probable Cause AUDIT, , [ZONE-3001], INFO, ZONE, , , , Event: , Status: success, Info: \"\" added to \"\". Indicates that a new zone object member or members have been added to the specified zone object set. The zone object type can be "alias", "zone member", "zone" or "zone configuration".
103 ZONE-3004 The zone object type can be “alias”, “zone member”, “zone” or “zone configuration”. The string “...” appears at the end of the zone object member list if the list was truncated in the message. Recommended Action Severity Verify the event was planned. If the event was planned, no action is required. If the event was not planned, take appropriate action as defined by your enterprise security policy.
ZONE-3007 103 ZONE-3007 Message AUDIT, , [ZONE-3007], INFO, ZONE, , , , Event: , Status: success, Info: Zone configuration \"\" enabled. . Probable Cause Indicates the specified zone configuration has been enabled. Recommended Action Verify the event was planned. If the event was planned, no action is required. If the event was not planned, take appropriate action as defined by your enterprise security policy.
103 ZONE-3011 Severity INFO ZONE-3011 Message AUDIT, , [ZONE-3011], INFO, ZONE, , , , Event: , Status: success, Info: Zone object \"\" expunged. Probable Cause Indicates the specified zone object has been expunged. Recommended Action Verify the event was planned. If the event was planned, no action is required. If the event was not planned, take appropriate action as defined by your enterprise security policy.
ZONE-3015 103 An AD object set type is “AD member”. The string “...” appears at the end of the AD object member list if the list was truncated in the message. Recommended Action Severity Verify the event was planned. If the event was planned, no action is required. If the event was not planned, take appropriate action as defined by your enterprise security policy.
103 ZONE-3018 ZONE-3018 Message AUDIT, , [ZONE-3018], INFO, FABRIC, , , , Event: , Status: success, Info: has been deactivated. Probable Cause Indicates the specified admin domain (AD) object has been deactivated. Recommended Action Verify the event was planned. If the event was planned, no action is required. If the event was not planned, take appropriate action as defined by your enterprise security policy.
ZONE-3022 Severity 103 INFO ZONE-3022 Message AUDIT, , [ZONE-3022], INFO, FABRIC, , , , Event: , Status: success, Info: Current AD configuration saved to flash. Probable Cause Indicates the current admin domain (AD) configuration has been saved to flash. Recommended Action Verify the event was planned. If the event was planned, no action is required.
103 ZONE-3025 Severity 606 INFO Fabric OS Message Reference 53-1001157-01